COMPONENT DESCRIPTION

The Super V System integrates components symmetrically to work with any furnace set-ups. All electronic components 
are located inside the filter access door. Change of filter is a breeze. It works in conjunction with the furnace to optimize 
the performance.  

*Replacement period depends on the level of pollution in the environment
** Replace Main Filter more often if pollution level is high
***Clean the High Energy Grid once a year or as needed

Note: The Super V system can be installed to a 208V-480V AHU/Furnace. 
Refer to Appendix A - “208V-480V input with EAC” for details. 

UNIT DESCRIPTION

The Super V 3400/5100 Whole House DFS Air Cleaning System is a high performance system that utilizes patent-
ed award winning Disinfecting Filtration System technology. DFS technology electrically enhances a low efficien-
cy, high flow, low pressure drop (0.27” @ 2000cfm /0.23” @ 3000cfm) filter to high efficiency while retaining the 
low pressure drop and longer life advantages of the base filter material. This technology has also been shown to 
inhibit bacteria growth on the filter by microbiostasis.

The Electrical Components are located inside the filter access door.

The Super V System is available in the following model:

The electrical power requirements for each individual unit are on the serial number label on 

the back side of the filter access door. These requirements supersede all other

 inferences to power requirements.

Components

Efficiency

Replacement/

Maintenance frequency*

DFS V-Bank Main Filter**

DFS V-Bank Main Filter**

Up to 99% Efficient (down to .007 microns)

Every 3 years at 50% duty cycle

High Energy Grid ***

Components

Description

Filter Access Door

Where the control panel , air flow monitor and electrical components located

Height

Width

Depth

Weight

Shipping Weight

SuperV 3400

24in

670mm 14in 356mm 27in 686mm

48lbs

22kg

58lbs

27kg

SuperV 5100

24in

670mm 14in 356mm 39in 990mm

65lbs

30kg

77lbs

35kg

System Overview

Model

Power Requirement

FLA

Power Usage

V

Hz

Phase

AMPS

WATTS

SuperV 3400/5100

110

50 / 60

1

0.08A - 110V

7W - 110V

Содержание SuperV 3400

Страница 1: ...SUPER V BANK FILTER HIGH ENERGY GRID The Super V Whole House Air Cleaner with Patented DFS Technology Model3400 5100 DFS Filtration System...

Страница 2: ......

Страница 3: ...SuperV 3400 Furnace Installation 10 SuperV 5100 Furnace Installation 11 System Operation 12 To Connect Unit to Power 12 To Turn on the Unit 12 To Turn off the Unit 12 Maintenance 12 SuperV 3400 Filter...

Страница 4: ...Cost Ease of Maintenance quick access to filter in a few steps Smart Air Flow Monitor Auto flow detection to turn on DFS power Designed to Last durable powder coated galvanized steel housing Hassle fr...

Страница 5: ...ilter Smaller filter 11 Extension filter Smaller filter ground Bracket 12 Extension filter Smaller filter contact bracket with spring 3 9 11 10 1 7 6 4 5 8 Exploded View 2 5100 Whole Unit Exploded Vie...

Страница 6: ...heed these warnings and notices may result in damage to the unit and or injury or death to personnel System Overview Performance data subject to change without notice 0 00 0 05 0 10 0 15 0 20 0 25 0 3...

Страница 7: ...ficiency while retaining the low pressure drop and longer life advantages of the base filter material This technology has also been shown to inhibit bacteria growth on the filter by microbiostasis The...

Страница 8: ...if damage is found Phone No 315 298 2904 1 800 843 3860 Fax No 315 298 6992 Email info healthway com LOCATION DETERMINATION The filtration system location should be carefully planned with consideratio...

Страница 9: ...Place the unit between the main inlet duct and furnace in a location which is accessible for checking and replacing the filter The unit is capable to be installed either left side or right side of th...

Страница 10: ...4 Locate the mounting holes from the unit and connect the unit to the furnace opening Fig 2 5 If the furnace and air cleaner openings are different use a transition plenum Fig 2 6 The opening on the...

Страница 11: ...the furnace Hold up the snap latch pull out the filter access door turn the quarter turn counter clockwise to unlock the filter and slide out both filters the smaller filter comes out first Fig 2 11 2...

Страница 12: ...certified filters HealthWay filters are designed for high voltage operation Use of non HealthWay filters can be hazardous to personnel and equipment voiding the warranty Always unplug the unit and tur...

Страница 13: ...or Fig 3 5 Fig 3 15 Fig 3 7 Fig 3 6 Fig 3 16 Fig 3 8 Fig 3 9 Fig 3 10 SUPERV 5100 FILTER REPLACEMENT Holdthelatchupandpulloutthefilteraccessdooroff Fig 3 11 3 12 Turnthequarter turncounter clockwiseto...

Страница 14: ...or other components of the High Energy Grid Make sure that any contaminant that falls to the bottom of the filter unit is removed In extreme cases it may be necessary to remove the wires from the spr...

Страница 15: ...high energy grid SSV3400_HEGridEXT PARTS LIST HealthWay recommends that the following spare parts be available on site at all times Order all parts by contacting Phone No 315 298 2904 1 800 843 3860...

Страница 16: ...any debris from the high energy grid area Step 7 Reinstall the high energy grid Main Filter and the Filter Access Door Turn the filter locks clockwise turn to lock the filter Plug in the Super V Syst...

Страница 17: ...ays lit the problem has been solved Probable Cause 3 Air flow monitor is not activated Solution Step 1 Turn off electrical power to furnace Step 2 Unplug the Super V System Step 3 Remove the Filter Ac...

Страница 18: ...ORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR...

Страница 19: ...120Vac 2 Relay UL listed by Functional Device PN RIBXGHF 0 5 150 amps 120V Max Sense Voltage 600Vac Appendix A Installation Schematics APPENDIX A INSTALLATION SCHEMATIC Installation for low pressure l...

Страница 20: ...20 Healthway 06 2019 All rights reserved Appendix A1 120V with EAC...

Страница 21: ...21 Healthway 06 2019 All rights reserved Appendix A2 120V without EAC...

Страница 22: ...22 Healthway 06 2019 All rights reserved Appendix A3 208 480V with EAC...

Страница 23: ...23 Healthway 06 2019 All rights reserved Appendix A4 208 480V without EAC...

Страница 24: ...3420 Maple Ave Pulaski New York 13142 USA Toll Free 1 800 843 3860 Int l 1 315 298 2904 healthway com...