FEATURES

 

• 

High Air Flow Capacity

 – delivers high CFM with low 

energy consumption

• 

Whole House Design 

– designed to deliver clean air  

for the whole house 

• 

Up to 99% Efficient on All Ultrafine Particles

 – down to a 

size of 0.007 microns 

• 

Versatile & Symmetrical Design

 –can be installed on 

either supply or return side of the furnace

• 

Patented V-Bank Filter

 –increases surface area and 

provides higher dust loading capacity

• 

Up to three times longer filter span

 – compared to 

conventional HEPA Filtration – Lower Maintenance Cost  

• 

Ease of Maintenance

 – quick access to filter in a few steps

• 

Smart Air Flow Monitor -  

Auto-flow detection to turn on 

DFS power

• 

Designed to Last

 - durable powder coated galvanized 

steel housing

• 

Hassle-free Installation

 - pre-drilled standing flanges to 

accommodate attachments to other system components 
and quick plug in for power to the system

• 

100% Sealed System

 - high memory sponge neoprene 

door gaskets to ensure door to filter seal and gaskets on 
main filter eliminate air bypass

Major Features and Exploded Views

SUPERV 3400 EXPLODED VIEW

High Energy Grid

High Energy Wire

Main Filter

Filter Access Door

Snap Latch

Main Housing

DFS Light

Power Switch

High Energy Contact Pad

3

9

1

7

6

4

5

8

Exploded View 1: 

3400 Whole Unit

2

Содержание SuperV 3400

Страница 1: ...SUPER V BANK FILTER HIGH ENERGY GRID The Super V Whole House Air Cleaner with Patented DFS Technology Model3400 5100 DFS Filtration System...

Страница 2: ......

Страница 3: ...SuperV 3400 Furnace Installation 10 SuperV 5100 Furnace Installation 11 System Operation 12 To Connect Unit to Power 12 To Turn on the Unit 12 To Turn off the Unit 12 Maintenance 12 SuperV 3400 Filter...

Страница 4: ...Cost Ease of Maintenance quick access to filter in a few steps Smart Air Flow Monitor Auto flow detection to turn on DFS power Designed to Last durable powder coated galvanized steel housing Hassle fr...

Страница 5: ...ilter Smaller filter 11 Extension filter Smaller filter ground Bracket 12 Extension filter Smaller filter contact bracket with spring 3 9 11 10 1 7 6 4 5 8 Exploded View 2 5100 Whole Unit Exploded Vie...

Страница 6: ...heed these warnings and notices may result in damage to the unit and or injury or death to personnel System Overview Performance data subject to change without notice 0 00 0 05 0 10 0 15 0 20 0 25 0 3...

Страница 7: ...ficiency while retaining the low pressure drop and longer life advantages of the base filter material This technology has also been shown to inhibit bacteria growth on the filter by microbiostasis The...

Страница 8: ...if damage is found Phone No 315 298 2904 1 800 843 3860 Fax No 315 298 6992 Email info healthway com LOCATION DETERMINATION The filtration system location should be carefully planned with consideratio...

Страница 9: ...Place the unit between the main inlet duct and furnace in a location which is accessible for checking and replacing the filter The unit is capable to be installed either left side or right side of th...

Страница 10: ...4 Locate the mounting holes from the unit and connect the unit to the furnace opening Fig 2 5 If the furnace and air cleaner openings are different use a transition plenum Fig 2 6 The opening on the...

Страница 11: ...the furnace Hold up the snap latch pull out the filter access door turn the quarter turn counter clockwise to unlock the filter and slide out both filters the smaller filter comes out first Fig 2 11 2...

Страница 12: ...certified filters HealthWay filters are designed for high voltage operation Use of non HealthWay filters can be hazardous to personnel and equipment voiding the warranty Always unplug the unit and tur...

Страница 13: ...or Fig 3 5 Fig 3 15 Fig 3 7 Fig 3 6 Fig 3 16 Fig 3 8 Fig 3 9 Fig 3 10 SUPERV 5100 FILTER REPLACEMENT Holdthelatchupandpulloutthefilteraccessdooroff Fig 3 11 3 12 Turnthequarter turncounter clockwiseto...

Страница 14: ...or other components of the High Energy Grid Make sure that any contaminant that falls to the bottom of the filter unit is removed In extreme cases it may be necessary to remove the wires from the spr...

Страница 15: ...high energy grid SSV3400_HEGridEXT PARTS LIST HealthWay recommends that the following spare parts be available on site at all times Order all parts by contacting Phone No 315 298 2904 1 800 843 3860...

Страница 16: ...any debris from the high energy grid area Step 7 Reinstall the high energy grid Main Filter and the Filter Access Door Turn the filter locks clockwise turn to lock the filter Plug in the Super V Syst...

Страница 17: ...ays lit the problem has been solved Probable Cause 3 Air flow monitor is not activated Solution Step 1 Turn off electrical power to furnace Step 2 Unplug the Super V System Step 3 Remove the Filter Ac...

Страница 18: ...ORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR...

Страница 19: ...120Vac 2 Relay UL listed by Functional Device PN RIBXGHF 0 5 150 amps 120V Max Sense Voltage 600Vac Appendix A Installation Schematics APPENDIX A INSTALLATION SCHEMATIC Installation for low pressure l...

Страница 20: ...20 Healthway 06 2019 All rights reserved Appendix A1 120V with EAC...

Страница 21: ...21 Healthway 06 2019 All rights reserved Appendix A2 120V without EAC...

Страница 22: ...22 Healthway 06 2019 All rights reserved Appendix A3 208 480V with EAC...

Страница 23: ...23 Healthway 06 2019 All rights reserved Appendix A4 208 480V without EAC...

Страница 24: ...3420 Maple Ave Pulaski New York 13142 USA Toll Free 1 800 843 3860 Int l 1 315 298 2904 healthway com...

Отзывы: