HealthWay 20600-3 Deluxe Скачать руководство пользователя страница 12

Reset respective indicators after replacing/cleaning filters

Reset MAIN FILTER FUNCTIONING indicator

•  If main filter is replaced 

after

 the timer is up (MAIN FILTER FUNCTIONING indicator starts flashing 

before replacement), press MAIN FILTER SERVICE button for 8 seconds to reset (fig 10). 
After reset, both the MAIN FILTER FUNCTIONING indicator and the BIOMONITOR DFS 
FUNCTIONING indicator resume solid green. 

•  If main filter is replaced 

before

 the timer is up (MAIN FILTER FUNCTIONING indicator has not yet 

started flashing), press MAIN FILTER SERVICE button for 8 seconds to end timer and the MAIN 
FILTER FUNCTIONING indicator will start flashing. Then press MAIN FILTER SERVICE button for 
another 8 seconds to reset timer. After reset, both the MAIN FILTER FUNCTIONING indicator and 
the BIOMONITOR DFS FUNCTIONING indicator resume solid green. 

Reset PREFILTER FUNCTIONING indicator. 

•  If prefilter is replaced 

after

 the timer is up (PREFILTER FUNCTIONING indicator starts flashing 

before replacement), press PREFILTER SERVICE button for 8 seconds to reset. After reset, the 
PREFILTER FUNCTIONING indicator resumes solid green. 

•  If prefilter is replaced 

before

 the timer is up (PREFILTER FUNCTIONING indicator has not yet 

started flashing), press PREFILTER SERVICE button for 8 seconds to end timer. The 
PREFILTER FUNCTIONING indicator starts flashing. Then press PREFILTER SERVICE button for 
another 8 seconds to reset timer. After reset, the PREFILTER FUNCTIONING indicator resumes 
solid green.

Routine Care & Maintenance 

( Routine Care & Maintance continued from page 11 )

fig 9

12

 

fig 10

Содержание 20600-3 Deluxe

Страница 1: ...S Disinfecting Filtration System Professional Air Cleaner Model No 20600 3 Return your Warranty Registration Card register your unit within 10 days of purchase 20600 3 Deluxe Healthy air for all your...

Страница 2: ...Color options vary depending on region market...

Страница 3: ...n HEPA performance at ultrafine particle levels Your choice of this Healthway Air Cleaner will bring pure air and create a healthier indoor environment for you and your loved ones Now let s get starte...

Страница 4: ...areas where combustible gases vapors or any other flammable materials are present 7 Never immerse or spray the unit with water or other liquids Do not clean the unit under running water 8 The air clea...

Страница 5: ...aptured contaminates 5 100 SEALED FILTRATION CHAMBER All incoming air is treated in the 100 sealed filter chamber 6 HIGHLY EFFICIENT DC MOTOR Drives a consistent volume of air and provides ultra quiet...

Страница 6: ...to reset prefilter timer e DFS ON OFF to turn DFS function on or off Control Panel Indicators fig 2 f LO Indicator when lit in blue unit is running at low speed g MED Indicator when lit in blue unit i...

Страница 7: ...Prefilter Functioning When lit in green prefilter is functioning When the green indicator flashes prefilter needs a replacement Biomonitor DFS Functioning When lit in green DFS function is on When th...

Страница 8: ...1 When unit is under normal operation and main filter is functioning the indicator is lit in green 2 When the green indicator flashes main filter needs a replacement DFS function is disabled automati...

Страница 9: ...t is under normal operation DFS function is turned on by default The BIOMONITOR DFS FUNCTIONING indicator is lit in green 2 Press DFS ON OFF button to turn such function on or off 3 When the MAIN FILT...

Страница 10: ...y 6 months High Energy Grid clean every 6 months Main filter replace every 9 12 months fig 3 fig 4 fig 5 10 Filter Replacement and Maintenance Prefilter Replacement and Maintenance Turn unit off and u...

Страница 11: ...brass pin Press filter down as shown fig 9 to lock filter in place move both gray handles 90 degrees towards the center of the filter To replace the lid align the 2 vertical tabs on the inside of the...

Страница 12: ...or another 8 seconds to reset timer After reset both the MAIN FILTER FUNCTIONING indicator and the BIOMONITOR DFS FUNCTIONING indicator resume solid green Reset PREFILTER FUNCTIONING indicator If pref...

Страница 13: ...Further examination by a trained technician is required Call HealthWay Customer Service or local distributor 4 MAIN FILTER FUNCTIONING indicator is OUT a The main filter needs to be replaced See the M...

Страница 14: ...defects in material or workmanship The sole responsibility of Healthway under this Limited Warranty is in its sole discretion to either repair or replace a duly registered product or defective part th...

Страница 15: ...ind and unless otherwise described by applicable state law Healthway shall not be liable for personal injury resulting from malfunctions defects misuse improper operation or installation or alteration...

Страница 16: ...All rights reserved Specifications subject to change without notification Manufacturer P N 20 167...

Отзывы: