Replacing the Main Filter
• To access DFS Main Filter, place fingertips under side recesses of black cover, gently pull upward
and lift cover to remove (fig 6). Separate lid from the main body.
• To release main filter, move both gray handles 90 degrees toward front of air purifier (fig 7).
• To remove the Main Filter, lift filter from the internal chamber (fig 8).
• Before installing the new Main Filter, make sure the filter seal ring is sealed properly in the ring
channel.
• To load DFS Main Filter, align hole with brass pin. Press filter down as shown (fig 9) to lock filter in
place, move both gray handles 90 degrees towards the center of the filter.
• To replace the lid, align the 2 vertical tabs, on the inside of the lid with the slots in the top of the
machine. Push down gently and snap shut. Be sure the lid is not backwards or the machine may
not turn on.
WARNING: Proper filters must be used and loaded correctly or the purifier will not turn on.
Do not force the handles. They should move freely. If not, realign the filter. For additional
instructions, call Healthway Customer Service Department or your local distributor.