Replacing the Main Filter

•  To access DFS Main Filter, place fingertips under side recesses of black cover, gently pull upward 

and lift cover to remove (fig 6). Separate lid from the main body.

•  To release main filter, move both gray handles 90 degrees toward front of air purifier (fig 7). 
•  To remove the Main Filter, lift filter from the internal chamber (fig 8). 
•  Before installing the new Main Filter, make sure the filter seal ring is sealed properly in the ring 

channel. 

•  To load DFS Main Filter, align hole with brass pin. Press filter down as shown (fig 9) to lock filter in 

place, move both gray handles 90 degrees towards the center of the filter. 

•  To replace the lid, align the 2 vertical tabs, on the inside of the lid with the slots in the top of the 

machine. Push down gently and snap shut. Be sure the lid is not backwards or the machine may 
not turn on.

WARNING: Proper filters must be used and loaded correctly or the purifier will not turn on. 
Do not force the handles. They should move freely. If not, realign the filter. For additional 
instructions, call Healthway Customer Service Department or your local distributor. 

fig 6

fig 7

fig 8

Routine Care & Maintenance 

( Routine Care & Maintance continued from page 10 )

11

Содержание 20600-3 Deluxe

Страница 1: ...S Disinfecting Filtration System Professional Air Cleaner Model No 20600 3 Return your Warranty Registration Card register your unit within 10 days of purchase 20600 3 Deluxe Healthy air for all your...

Страница 2: ...Color options vary depending on region market...

Страница 3: ...n HEPA performance at ultrafine particle levels Your choice of this Healthway Air Cleaner will bring pure air and create a healthier indoor environment for you and your loved ones Now let s get starte...

Страница 4: ...areas where combustible gases vapors or any other flammable materials are present 7 Never immerse or spray the unit with water or other liquids Do not clean the unit under running water 8 The air clea...

Страница 5: ...aptured contaminates 5 100 SEALED FILTRATION CHAMBER All incoming air is treated in the 100 sealed filter chamber 6 HIGHLY EFFICIENT DC MOTOR Drives a consistent volume of air and provides ultra quiet...

Страница 6: ...to reset prefilter timer e DFS ON OFF to turn DFS function on or off Control Panel Indicators fig 2 f LO Indicator when lit in blue unit is running at low speed g MED Indicator when lit in blue unit i...

Страница 7: ...Prefilter Functioning When lit in green prefilter is functioning When the green indicator flashes prefilter needs a replacement Biomonitor DFS Functioning When lit in green DFS function is on When th...

Страница 8: ...1 When unit is under normal operation and main filter is functioning the indicator is lit in green 2 When the green indicator flashes main filter needs a replacement DFS function is disabled automati...

Страница 9: ...t is under normal operation DFS function is turned on by default The BIOMONITOR DFS FUNCTIONING indicator is lit in green 2 Press DFS ON OFF button to turn such function on or off 3 When the MAIN FILT...

Страница 10: ...y 6 months High Energy Grid clean every 6 months Main filter replace every 9 12 months fig 3 fig 4 fig 5 10 Filter Replacement and Maintenance Prefilter Replacement and Maintenance Turn unit off and u...

Страница 11: ...brass pin Press filter down as shown fig 9 to lock filter in place move both gray handles 90 degrees towards the center of the filter To replace the lid align the 2 vertical tabs on the inside of the...

Страница 12: ...or another 8 seconds to reset timer After reset both the MAIN FILTER FUNCTIONING indicator and the BIOMONITOR DFS FUNCTIONING indicator resume solid green Reset PREFILTER FUNCTIONING indicator If pref...

Страница 13: ...Further examination by a trained technician is required Call HealthWay Customer Service or local distributor 4 MAIN FILTER FUNCTIONING indicator is OUT a The main filter needs to be replaced See the M...

Страница 14: ...defects in material or workmanship The sole responsibility of Healthway under this Limited Warranty is in its sole discretion to either repair or replace a duly registered product or defective part th...

Страница 15: ...ind and unless otherwise described by applicable state law Healthway shall not be liable for personal injury resulting from malfunctions defects misuse improper operation or installation or alteration...

Страница 16: ...All rights reserved Specifications subject to change without notification Manufacturer P N 20 167...

Отзывы: