• Open the battery cover.
• Install the batteries by matching 

the correct polarity, as shown.

• Replace the cover.

Installing and Replacing the Batteries

Remove batteries if the device is not likely to be used for some time.

The old batteries are harmful to the environment, do not dispose with other daily trash.

Remove the old batteries from the device and follow your local recycling guidelines.

CAUTION

Replace the batteries whenever the below happen

The             shows

The display dims

The display does not light up

Do not dispose of batteries in fire. Batteries may explode or leak.

The Choice of Power Supply

1

.

Battery powered mode:

    6VDC 4×AAA batteries

2

.

AC adaptor powered mode:

   6V     1A (Micro USB plug)

(Please only use the recommended  AC 
adaptor model). 

Please unplug the adaptor to depart from

the using utility power.

7

4.User manual

3. 4×AAA  batteries

List

2.Cuff  (Type BF applied part)

              (22cm~

1.Blood Pressure Monitor  

(Hea -Mate BP 120 Classic)

rt

6

 

In order to get the best effect and protect your monitor,please use the right 

battery and special power adaptor which complies with CE safety standard.

CAUTION

5. Warranty Card

42cm)

(Please use HEALTHSENSE 
authorized cuff. The size of 
the actual cuff please refer to 
the label on the attached 
cuff.)

INTRODUCTION

BEFORE YOU START

Cuff Connector Port

Monitor Components

SET

MEM

START

STOP

AC adaptor (excluded)

AC Adapter Port

CUFF

 AIR HOSE

Battery Compartment

SET

MEM

START

STOP

LCD Display

Setting

Start/Stop

Memory

SET

MEM

START

STOP

Содержание Classic BP 120

Страница 1: ...carefully and thoroughly so as to ensure the safe usage of this product and keep the manual well for further reference in case you have problems Thank you very much for selecting Pressure Monitor BP 1...

Страница 2: ...nitor Components 6 2 BEFORE YOU START The Choice of Power Supply Installing and Replacing the Batteries 7 Measurement Principle 8 Setting User Date Time Measurement Unit 8 10 Select the User 11 7 1 CA...

Страница 3: ...ood pressure of children Ask your doctor before using it on older children The device is not suitable for use on pregnant women patients with implanted electrocical devices patients with pre elcampsia...

Страница 4: ...ipment is not AP APG equipment and not suitable for use in the presence of a flammable anesthetic mixture with air of with oxygen or nitrous oxide This unit is not suitable for continuous monitoring d...

Страница 5: ...batteries 2 AC adaptor powered mode 6V 1A Micro USB plug Please only use the recommended AC adaptor model Please unplug the adaptor to depart from the using utility power 7 4 User manual 3 4 AAA batt...

Страница 6: ...stolic pressure and also pulse rate The device also compares the longest and the shortest time intervals of detected pulse waves to mean time interval then calculates standard deviation The device wil...

Страница 7: ...ll display 2 Press SET button to select the user ID between user A and user B 3 After selecting the suitable user ID Press START STOP to confirm and turn off LCD button 10 BEFORE YOU START BEFORE YOU...

Страница 8: ...easurements at approximately the same time position of upper arm or as directed by a physician 2 3cm Patients with Hypertension The middle of the cuff should be at the level of the right atrium of the...

Страница 9: ...B After selecting user B repeat steps 1 2 as per page 14 to read average memory readings for user B START STOP to turn Recall the Records 1 When the monitor is off button to show the average value of...

Страница 10: ...llowing circumstances 16 If you did not get the correct measurement you can delete all results by following steps below Take User A for example Delete the Records 1 Press MEM button to enter memory mo...

Страница 11: ...was detected during measurement Usually this is NOT a cause for concern However if the symbol appears often we recommend you seek medical advice Please note that the device does not replace a cardiac...

Страница 12: ...Taking 2 3 deep breaths before beginning will be better for measuring Advice Relax yourself for 4 5 minutes until you calm down Upper arm is not covered or pressed by gusset Cuff and the heart are at...

Страница 13: ...tor powered mode 6V 1A Please only use the recommended AC adaptor model excluded TROUBLESHOOTING PROBLEM REMEDY No Power Check the battery power Check the battery polarity position Replace with new se...

Страница 14: ...rements for electromechanical blood pressure measuring system EN 1060 4 2004 Automatic Blood Pressure Monitor overall system Interventional accuracy of the testing process IEC EN 60601 1 6 2010 Medica...

Страница 15: ...s wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance d 3 3m away from the equipment...

Отзывы: