background image

P/N UM402LB REV20190501 

15 

WARRANTY 

10-Year Limited Warranty 

 

What does the Warranty Cover? 

This Health o meter

®

 Professional scale is warranted from date of purchase against defects of materials or in 

workmanship for a period of ten (10) years. If product fails to function properly, return the product, freight prepaid and 
properly packed to 

Pelstar, LLC (see “To Get Warranty Service”, below, for instructions). If the manufacturer 

determines that a defect of material or in workmanship exists, the customer’s sole remedy will be replacement of the 
scale at no charge. Replacement will be made with a new or remanufactured product or component. If the product is 
no longer available, replacement may be made with a similar product of equal or greater value. All replaced parts are 
covered only for the original warranty period. 

Who is Covered? 

The original purchaser of the product must have proof of purchase to receive warranty service. Please save your 
invoice or receipt.  Pelstar dealers or retail stores selling Pelstar products do not have the right to alter, or modify or 
any way change the terms and conditions of this warranty. 

What is Excluded? 

Your warranty does not cover normal wear of parts or damage resulting from any of the following:

 negligent 

use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, abuse 
including tampering, damage in transit, or unauthorized repair or alternations. Further, the warranty does not cover 
natural disasters, such as fire, flood, hurricanes and tornadoes. This warranty gives you specific legal rights, and you 
may also have other rights that vary from country to country, state to state, province to province or jurisdiction to 
jurisdiction. 

To get Warranty Service make sure you keep your sales receipt or document showing proof of purchase. 

Call 

(+1) 800-638-3722 or (+1) 708-377-0600 to receive a return authorization (RA) number, which must be included on 
the return label. Attach your proof of purchase to your defective product along with your name, address, daytime 
telephone number and description of the problem. Carefully package the product and send with shipping and 
insurance prepaid to:

 

Pelstar, LLC 
Attention R/A#_____________ 
Return Department 
9500 West 55

th

 Street  

McCook, IL 60525 
 

Typical product life is 10 years or 100,000 cycles but may vary significantly based on daily usage, treatment 
and other factors. 

 

 

                                                                   

                                                                                 

 

PELSTAR, LLC 

9500 West 55th St. McCook, IL 60525-7110  USA 

1-800-638-3722 or 1-708-377-0600 

PLEASE REGISTER YOUR SCALE FOR WARRANTY COVERAGE AT: 

 www.homscales.com 

 

Health o meter

®

 is a registered trademark of Sunbeam Products, Inc. used under license. 

Health o meter

®

 Professional products are manufactured, designed, and owned by Pelstar, LLC. 

We reserve the right to improve, enhance, or modify Health o meter

®

 Professional product features or specifications 

without notice. 

© Pelstar, LLC 2019 

 

 

QNET BV 
KANTSTRAAT 19 
NL-5076 NP HAAREN 
THE NETHERLANDS 

0459 

Содержание 402LB

Страница 1: ...P N UM402LB REV20190501 1 402LB Physician Beam Scale User Instructions PELSTAR LLC 9500 West 55th St McCook IL 60525 7110 USA www homscales com Health o meter Professional 402LB Pelstar LLC 2019 0459 ...

Страница 2: ...ifications for This Scale 4 Certifications Disposal Service 4 Assembly Instructions 5 Operating Instructions 7 Height Measurement Instructions 9 Transportation 11 Troubleshooting 12 Maintenance and Cleaning 14 Warranty 15 Note This scale has been factory calibrated and does not require calibration prior to use Please register your scale for warranty coverage at www homscales com For User Instructi...

Страница 3: ...xercise caution when assembling the scale pillar Assemble and operate the scale per the enclosed user instructions For accurate weighing this scale must be placed on a flat stable surface For accurate weighing verify before each use the proper operation according to the procedure described in this manual Do not use in the presence of flammable or explosive materials If the scale becomes damaged it...

Страница 4: ...28 lb 12 7 kg Platform Standing Area Width 10 1 2 26 7cm Depth 14 35 6 cm Height 3 1 4 8 3 cm Certification Descriptions Scale Disposal This Health o meter Professional scale must be disposed of properly as steel waste Follow the national regional or local regulations which apply to you for disposal of steel waste Customer Service Information The 402LB physician beam scale is shipped disassembled ...

Страница 5: ... after receipt of the package The following information details what you will find inside the main carton as you unpack the parts for assembly To prevent scratching any components and avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any sharp object to open the protective inner packaging Carefully remove each assembly from the carton and unwrap the packing ma...

Страница 6: ...the top of the platform base Insert the studs into the platform base Note If a chair is not available it is recommended that one person holds the platform base while another person handles the pillar 3 Access the underside of the scale base Obtain the four pillar nuts in the carton and place onto the studs on the underside of the scale base Using the provided wrench tighten the pillar nuts to secu...

Страница 7: ...poise weights to indicate the patient s approximate weight 2 Have patient step onto the scale Ensure they are positioned directly in the center of the platform Continue to adjust the upper and lower poise weights until the pointer is centered Note It is not necessary for you to wait for the pointer to stop moving in order to read the correct weight As long as the pointer is moving equally within t...

Страница 8: ... UM402LB REV20190501 8 OPERATING INSTRUCTIONS CONTINUED Indicator Value reads 27 25 lb 27 lb 4 oz Value reads 100 lb Combined value 100 lb 27 25 lb 129 75 lb Or Combined value 100 lb 27 lb 4 oz 127 lb 4 oz ...

Страница 9: ...e headpiece up or down to the estimated height of the patient Then raise the headpiece into its horizontal position To lower height rod below 46 push the tab at the top of the height rod and gently lower the headpiece 2 Ensure that the patient s posture is upright and that the patient s head is straight and level Slide the headpiece down until it rests on the patient s head 3 Determine the patient...

Страница 10: ...MEASUREMENT INSTRUCTIONS CONTINUED Height Rod Below 46 3 8 bove 46 3 8 Height Rod Extended A Cm read 176 cm 0 2 cm 176 2 cm Cm read 105 cm 0 2 cm 105 2 cm Inches read 41 3 8 41 3 8 Inches read 69 3 8 69 3 8 Headpiece Indicator Indicator ...

Страница 11: ...floor Position the clamping plate inside the base by aligning the holes in the clamping plate and base 3 Position the wheel bracket onto the base by aligning the holes in the wheel bracket with the holes in the clamping plate 4 Insert the mounting screws through the wheel bracket and into the clamping plate Using a wrench tighten the mounting screws to secure the wheel bracket to the base Carefull...

Страница 12: ... trig loop in its range of travel Realignment of the beam may be necessary if it is touching Ensure that the upper and lower poise weights are firmly against the shoulder of the beam Adjust the balance ball screw by turning the screw at the left end of the bar Platform rocks excessively or touches base at any corner Base out of alignment Follow the base alignment instructions on the next page Beam...

Страница 13: ...erside of the base obtain a sturdy chair and place the top of the pillar with the height rod side facing down on the seat of the chair as shown 3 On the underside of the scale base remove the two black caps from the heel end 4 With the caps removed you can access the alignment screws that allows the heel end of the base to move up or down Use a 7 64 or 1 8 allen wrench to adjust the screws As you ...

Страница 14: ...parts are permanently lubricated DO NOT USE OIL OR LUBRICANTS Cleaning and Disinfecting Proper care and cleaning is essential to ensure a long life of accurate and effective weighing 1 Health o meter Professional recommends using one of the following solutions on a soft cloth or disposable wipe mild soap and water solution 70 isopropyl alcohol solution with 1 5 hydrogen peroxide concentration Afte...

Страница 15: ...ding tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover natural disasters such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty Service make sure you keep your...

Отзывы: