TitanMig Pulse 270/3500/5000 Operators Manual
Issue. A 0516
18
parameter is selected
1) For MIG welding process:
the inductance value 0 is recommended reference range. Value less than
0 give a rougher arc and increased stability. Value greater than 0 give a smoother arc and less spatter.
2) For pulse MIG welding process
: The droplet transfer force will be increased according the
inductance value changed from less than 0 to greater than 0.
3) For MMA welding process
: the arc force value 0 means soft and spatter small arc, value 100 means
hard and stable arc. When the display value is Job, the welding parameter can be stored and
recalled. Please refer to the details on section 3.2
12.
Job no. LED
lights up when the job number parameter is selected
13.
Value indicator LED
lights up when the other indicator parameter is selected
14.
Adjusting dial for altering welding parameters.
If the indicator on the adjusting dial is lit up, then the selected parameter is one that can be altered
15.
Gas test button
for setting the required gas flow rate on the pressure regulator. Gas will flow out for 30 s after
pressing the gas test button. Press the button again to stop the gas test flow before the end of this
period.
16.
Wire diameter button
for selecting the diameter of the wire to be used. Parameter SP is reserved for additional wire
diameters. When a wire diameter is selected, the LED behind the relevant wire diameter lights up.
Содержание TitanMig Pulse 2700
Страница 2: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 ...
Страница 36: ...TitanMig Pulse 270 3500 5000 Operators Manual Issue A 0516 32 4T Special 2T ...
Страница 53: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 49 ...
Страница 56: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 52 J Now data has being transmitted K k Complete ...
Страница 65: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 61 6 0 Electrical Diagram ...
Страница 70: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 66 ...
Страница 71: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 67 ...