HDE V-DETECT Скачать руководство пользователя страница 1

Operating & Instruction Manual

Making

the

Invisible

Visible

®

V-DETECT

a n d AC C E S S O R I E S

AC VOLTAGE DETECTOR

1475 Lakeside Drive • Waukegan, Illinois 60085 U.S.A. • 847.473.4980

f a x   8 4 7 . 4 7 3 . 4 9 8 1   •   we b s i t e :   w w w. H D E l e c t r i c C o m p a ny. c o m

Содержание V-DETECT

Страница 1: ...ng Instruction Manual Making the Invisible Visible V DETECT and ACCESSORIES AC VOLTAGE DETECTOR 1475 Lakeside Drive Waukegan Illinois 60085 U S A 847 473 4980 fax 847 473 4981 website www HDElectricCompany com ...

Страница 2: ...2 ...

Страница 3: ...T AC Voltage Detectors have user selectable voltage ranges covering the range from secondary voltages to the highest transmission voltages Accessories may include a holster charging cord for charging the unit from a car or truck a 115 240VAC wall charger adapter a carrying bag and a carrying case OPERATIONAL IMPAIRMENT If the V DETECT AC Voltage Detector is used in a manner not described in this i...

Страница 4: ...r working order by pressing the ON button and checking that all voltage range lights turn on in turn and that the unit stays on following the self test Never allow another high voltage or grounded conductor to contact the instrument during use Keep the housing free and clear of all structures at all times Bridging the housing from line to ground or line to line may cause a fault and arc The V DETE...

Страница 5: ...est it has passed the self test and is ready to use If it turns off after this test then it has not passed the self test and must be recharged or serviced While the instrument is on it will emit a very short beep and flash of the lights once every FOUR SECONDS 3 SELECT A VOLTAGE RANGE Use the up and down arrows to select a voltage range The lowest range setting is indicated by the lowest voltage r...

Страница 6: ...ested as sensing distance will be reduced or diminished NEVER allow prolonged arcing between an energized conductor and the instrument This will damage the housing of the unit NEVER bridge between conductors with the housing This may result in an arc and or fault NEVER select a voltage range above the voltage of the conductor to be tested The instrument may not detect voltage on the conductor bein...

Страница 7: ...ours When the charge is complete only the highest voltage range light will remain on After three hours this light will turn off The battery cannot be overcharged A quick fifteen minute charge to a low battery will allow one day of use under typical conditions A full charge will allow more than one week of continuous use under typical conditions If the instrument will not turn on try charging it fo...

Страница 8: ...DIMENSIONS 11 L x 3 W x 2 D 28 cm x 7 6 cm x 5 cm WEIGHT 11oz 0 31 kg OPERATING FREQUENCY 25Hz 400Hz BEEPER SOUND PRESSURE LEVEL 100 db BATTERY LIFE One week of typical daily use after full charge BATTERY CHARGING CURRENT 0 5A maximum at 12VDC ENCLOSURE MATERIAL Supertough Nylon UL 94 HB PRINTED CIRCUIT BOARDS FR 4 UL94V 0 ENVIRONMENTAL CONDITIONS CONDITIONS Indoor and outdoor use ALTITUDE Up to 6...

Страница 9: ...r if the battery cover is lost CAUTION High Voltage WARNING Do not use this tester except as directed Do not use to test equipment other than specified V DETECT AC Voltage Detectors Do not apply to energized circuits or equipment Do not operate this Tester without the battery cover and do not open the housing Refer all servicing to the factory Failure to follow these instructions may lead to elect...

Страница 10: ...CARRYING HOLSTER Carrying holster with belt clip and restraining strap D CS DET CARRYING CASE Carrying case holds V DETECT Detector PRX HS PT VDET Tester and charge cords E VDET BAG CARRYING BAG Padded carrying bag with strap holds V DETECT Detector PRX HS PT VDET Tester and charge cords F HOT STICKS A range of hot sticks are available Contact HD Electric for more details A F D C E B ...

Страница 11: ...11 ...

Страница 12: ... beyond HDE s reasonable control Deliveries or other performance may be suspended for an appropriate period or cancelled by HDE upon notice to Buyer in the event of any of the foregoing but the balance of this agreement shall otherwise remain unaffected If HDE determines that its ability to supply the total demand for the Goods or to obtain material used directly or indirectly in the manufacture o...

Отзывы: