HDE CDM-50 Скачать руководство пользователя страница 5

5

Hints & Guidelines

Position the unit on the ground, directly underneath the cable to
be measured. Align the unit in the direction of the cable, with the
cone pointing towards the cable, as shown.

When taking cable measurements, ensure that there are no
walls or buildings within a distance of 7 feet (2m) on either side
of the meter, as reflections from these will distort the readings.
Also ensure there are no trees or other overhanging objects in
the vicinity.

When measuring more than one cable, ensure that none of the
cables are outside the sonic beam, as shown in the Performance
section of this manual. If the cables are not vertically above one
another, this could be the case. In this instance, it will be necessary
to take a number of separate readings
from different positions.

Water and moisture can cause the
Cable Distance Meter to malfunction.
Therefore, the meter should not be
used in rain or snow. If water does
get into the cone, leave it upside
down in a dry, warm area.

If the display shows – – – . – – – , this
indicates a “poor target” and normally
happens when the cables are moving
due to wind, etc. Wait until the wind
dies down to get an accurate reading.

CALIBRATE MODE

The Calibrate mode switch allows the user to periodically check the unit to ensure that
it is still operating within specification. For cable distance measurement, this switch
should be in the CABLE position. When the switch is put to the WALL position, horizontal
measurements to large objects, e.g. walls, can be taken.

When the unit is first used, a horizontal reading to an object, e.g. wall, from a fixed position
should be taken. The reading should be entered, together with the date, into the table below.
Whenever the unit is to be checked for accuracy, a reading should be taken from the same
point, noting the result and date in the table. If the reading is outside of specification, the unit
should be returned to HD Electric for calibration.

Date

Reading

Front
View

Side View

Содержание CDM-50

Страница 1: ...CDM 50 CDM 75 C A B L E D I S TA N C E M E T E R S Operating Instruction Manual 1475 Lakeside Drive Waukegan Illinois 60085 U S A 847 473 4980 fax 847 473 4981 website www HDElectricCompany com ...

Страница 2: ...2 ...

Страница 3: ...g the ambient temperature using the internal temperature sensor The display continuously shows the ambient temperature reading Because the temperature sensor reacts relatively slowly to large temperature changes it is necessary to wait up to 10 minutes for the temperature reading to stabilize after taking the meter suddenly from a warm to a cold environment before taking a measurement e g taking t...

Страница 4: ...hold the MEASURE key to take a measurement The distance to the first cable is shown intheHeightMeasurement locationinthedisplay Ifthereismorethanone cablepresent the difference in height between each cable is stored in memory 6 Press the READ CABLES 1 6 key to display each of the cable height differences stored in memory Stored Measurements The unit will automatically turn off 3 minutes after the ...

Страница 5: ...herefore the meter should not be used in rain or snow If water does get into the cone leave it upside down in a dry warm area If the display shows this indicates a poor target and normally happens when the cables are moving due to wind etc Wait until the wind dies down to get an accurate reading CALIBRATE MODE The Calibrate mode switch allows the user to periodically check the unit to ensure that ...

Страница 6: ...ement andWALL for horizontal distance to object measurement Ensure no walls or similar obstructions are within 7 feet 2m of either side of the unit as reflections from these can interfere with correct operation SPECIFICATIONS Model CDM 50 Model CDM 75 1 inch 25mm Cable Diameter 10 50 3m 15m 10 75 3m 23m 0 5 inch 12mm Cable Diameter 10 50 3m 15m 10 50 3m 15m 0 25 inch 5 5mm Cable Diameter 10 40 3m ...

Страница 7: ...1 4m 50ft 15m 75 ft O ft 0 5 in 12mm 1 in 25mm 1OO ft Minimum Cable Diameter 50 ft 50ft 15m 3ft 0 9m Beam Width 3ft 0 9m 40ft 12m 33ft 10m 33ft 10m 33 ft O ft 0 125 in 2 5mm 0 25 in 5 5mm 0 5 in 12mm 1 in 25mm PERFORMANCE CDM 50MeasurementversusCableDiameter CDM 75MeasurementversusCableDiameter ...

Страница 8: ...olete unavailable over time end of life In the event that a Product cannot be repaired or replaced due to unavailability of parts HD Electric Company will use commercially reasonable efforts to obtain substitute parts or conduct work around design but cannot guarantee its ability to do so Items not found defective will be returned at your expense or failing receipt of instruction from you on retur...

Отзывы: