LIMITED  WARRANTY

HD FIRE PROTECT PVT. LTD. hereby referred to as HD FIRE warrants to the original purchaser of the fire protection products manufactured by HD FIRE and to any other person 
to whom such equipment is transferred, that such products will be free from defect in material and workmanship under normal use and care, for two (2) years from the date of 
shipment by HD FIRE. Products or Components supplied or used by HD FIRE, but manufactured by others, are warranted only to the extent of the manufacturer’s warranty. 
No warranty is given for product or components which have been subject to misuse, improper installation, corrosion, unauthorized repair, alteration or un-maintained. 
HD FIRE shall not be responsible for system design errors or improper installation or inaccurate or incomplete information supplied by buyer or buyer’s representatives.
HD FIRE will repair or replace defective material free of charge, which is returned to our factory, transportation charge prepaid, provided after our inspection the material is 
found to have been defective at the time of initial shipment from our works. HD FIRE shall not be liable for any incidental or consequential loss, damage or expense arising directly 
or indirectly from the use of the product including damages for injury to person, damages to property and penalties resulting from any products and components manufactured 
by HD FIRE. HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product. HD FIRE shall not be liable for any 
damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fire’s product liability exceed an amount equal to the sale price.
The foregoing warranty is exclusive and in lieu of all other warranties and representation whether expressed, implied, oral or written, including but not limited 
to, any implied warranties or merchantability or fitness for a particular purpose. All such other warranties and representations are hereby cancelled.

NOTICE :

The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the 
provision of government codes or ordinances wherever applicable.
The information provided by us is to the best of our knowledge and belief, and consist of general guidelines only. Site handling and installation control is not in our scope. 
Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or 
damages due to our product.
Product development is a continuous programme of HD FIRE PROTECT PVT. LTD. and hence the right to modify any specification without prior notice is reserved with 
the company.

D-6/2, ROAD NO. 34, WAGLE INDUSTRIAL ESTATE, THANE 400 604, INDIA.
• TEL: + (91) 22 2158 2600 

• FAX: +(91) 22 2158 2602

• EMAIL: [email protected] 

• WEB: www.hdfire.com

HD FIRE PROTECT PVT. LTD.

Protecting What Matters Most to You

Содержание K FACTOR-8

Страница 1: ... of areas with finished ceilings or walls Sprinkler Operation The Sprinkler operating device is state of the art heat responsive frangible glass bulb supplied by a world leader in this innovative technology The glass bulb contains fluid which expands when exposed to heat When rated temperature is reached the bulb shatters and water flows through the sprinkler and strikes deflector forming a unifor...

Страница 2: ...ing sprinkler temperature rating but the temperature rating is still stamped on the sprinkler deflector SPRINKLER RATINGS SPRINKLER TEMP CLASSIFICATION NORMAL SPRINKLER TEMP RATING NFPA MAX CEILING TEMP ALLOWED GLASS BULB COLOUR Ordinary 57 C 135 F 38 C 100 F Orange Ordinary 68 C 155 F 38 C 100 F Red Intermediate 79 C 175 F 66 C 150 F Yellow Intermediate 93 C 200 F 66 C 150 F Green Material Specif...

Страница 3: ... SPRINKLER 30 32 mm 16 5 mm 52 4 mm 34 35 mm 16 5 mm 51 6 mm TYPICAL WALL FINISHED SURFACE 38 08mm 18 58mm FINISHED SURFACE TYPICAL WALL MAXIMUM EXTENSION MAXIMUM RECESS MAX HOLE 0 60mm MAX HOLE 0 60mm MIN HOLE 0 54mm MIN HOLE 0 54mm PENDENT UPRIGHT Tolerance for all dimensions 0 5 mm ...

Страница 4: ...5 305 245 185 135 75 50 100 150 200 250 300 120 230 K8 0 PENDENT SPRINKLER DISTRIBUTION PATTERNS TRAJECTORY 175 psi 50 psi 100 psi 20 psi 275 Distribute the water distance cm Mounting height cm 215 165 1054 5 3052 45 185 135 75 45 105 1652 15 275 305 245 185 135 75 50 100 150 200 250 300 120 230 100 psi 175 psi 20 psi 50 psi K8 0 UPRIGHT SPRINKLER DISTRIBUTION PATTERNS TRAJECTORY ...

Страница 5: ...LPM PRESSURE IN PSI 0 51 5 2 53 5 4 55 5 6 5 7 7 5 8 8 5 9 71 52 03 03 54 55 05 56 57 08 08 59 5 100 105 115 120 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 60 21 26 16 31 37 42 48 53 58 63 69 74 79 85 90 95 100 106 DISCHARGE IN GPM NOMINAL K 8 0 NOMINAL K 114 TOOLS SPRINKLER WRENCH SPRINKLER KEY ...

Страница 6: ...ed by HD FIRE HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product HD FIRE shall not be liable for any damages or charges sustained in the adaptation or use of its engineering data services In no event shall HD Fire s product liability exceed an amount equal to the sale price The foregoing warranty is exclusive and in lieu of all ot...