Introduction

This manual will help with the installation, parameter 

setting, troubleshooting and general maintenance 

requirements for the Controller. To guarantee the 

safe and reliable operation of  this Control, you must 

first read this manual in detail and take particular note 

to any and all warnings or caution directives prior to 

connecting to AC power. 

Only suitably qualified individuals with formal training 

in electrical and HVAC controls should attempt the 

installation of  this equipment. Incorrect wiring and 

installation will affect the warranty provided with this 

unit. Wiring must be completed in accordance with the 

codes and practices applicable to the jurisdiction for the 

actual installation. 

The HBX WAV-0110 is a microprocessor based 

controller and as such is not to be regarded as a safety 

(limit) control. Please consult and install the heating or 

cooling appliance in accordance with the manufacturer’s 

recommendations.

SAFETY SYMBOLS AND WARNINGS:

Extreme Hazard -

This action poses a serious threat that could 

result in personal injury or death, as well 

as permanent damage to the equipment. 

Proceed with caution.

Moderate Hazard -

This action may cause personal injury or 

have adverse effects on the installation 

process if  handled incorrectly.

Disconnect Power Source -

The presence of low voltage(24VAC) or high 

voltage(120VAC) could result in personal 

injury or permanent damage to components 

or equipment.

Point of  Interest -

This point clarifies pertinent information, 

or brings your attention to an action that 

may have adverse effects on the installation 

process.

RECEIVING, INSPECTION
AND STORAGE

This HBX WAV-0110 has gone through rigorous quality 

control tests at the factory before shipment. After 

receipt and before installation perform the following 

checks:

Receipt

After receiving, inspect the unit for any possible 

physical damage that may have occurred during 

transportation.  

Inspection

After unpacking the unit make sure the box contains:

•  1 x Base Unit

•  1 x Outdoor Unit

• 

2.5mm Screwdriver

•  2 x AA Batteries (installed in Outdoor Unit)

• 

Instruction Manual 

Make sure the part number on the unit corresponds to 

the part number on the original box. 

Storage

The WAV-0110 should be kept in its original shipping 

carton prior to installation.  In order to retain the 

warranty coverage it should be stored properly:

• 

Store in a clean dry place

• 

Store within an ambient temperature range of  +10ºC 

to +40ºC

• 

If  possible, store in an air-conditioned environment 

where the relative humidity is less than 95%

• 

Do not store in places where the unit  may come into 

contact with corrosive gases or liquids

• 

Do not store in an area or upon an unstable surface 

where it may become damaged due to falling

Содержание WAV-0110

Страница 1: ...Page 1 HBX Control Systems Inc WAV 0112 WAV 0111 WAV 0110 Installation Manual WAV 0110 WAV 0111 WAV 0112 Version 1 005...

Страница 2: ...o Safety Symbols and Warnings 3 o Receiving Inspection and Storage 3 o Description 4 o Technical Data and Dimensions 5 Installation and Wiring 6 8 o Mounting and Wiring 6 o Setting the Dipswitches 6 o...

Страница 3: ...rsonal injury or have adverse effects on the installation process if handled incorrectly Disconnect Power Source The presence of low voltage 24VAC or high voltage 120VAC could result in personal injur...

Страница 4: ...0 are Temperature range 20 F to 225 F operating temperature range down to 40 F Proprietary pairing and communication protocol 500 5k 10k 20k Ohm thermistor options built in dipswitch selectable Provid...

Страница 5: ...MB Contains FFC ID 0A3MRF24J40MB Dimensions OZ OZ THERM OUT 24 VAC GND Signal Power OZ OZ THERM OUT 24 VAC GND 116 mm 78 mm 114 mm 76 mm Front View Outdoor Sensor Inside View Indoor Sensor Inside View...

Страница 6: ...r Vitodens 200 setup Dip 1 ON only 500 Ohms Dip 2 ON only 5k Ohms Both ON 20k Ohms Both OFF 10k Ohms Default Setting ON ON ON ON ON ON ON ON Dip 1 ON only 500 Ohms Dip 2 ON only 5k Ohms Both ON 20k Oh...

Страница 7: ...ed on the outdoor sensor until the red LED light turns off approx 15 seconds then release the button The LED will switch back on after a few seconds as it is initiating the pairing process see FIG 6 O...

Страница 8: ...also at least 1 foot away from any metal in all directions so there is not interference with the wireless sensor FIG 9 Do not mount the outdoor sensor with the conduit knockout facing upwards as rain...

Страница 9: ...or sensor and press the button referred to on page 7 which will force the outdoor unit to send a temperature to the base unit If after trying this step the base unit is still in Loss of Communication...

Страница 10: ...64129 5 41 53777 8 47 45249 9 49 42750 13 55 36111 16 61 30615 19 67 26037 23 73 22200 26 79 18994 29 85 16297 33 91 14016 Temp C Temp F Resistance Ohms Dip 1 ON only 500 Ohms Dip 2 ON only 5k Ohms B...

Страница 11: ...d above the purchasers sole remedy shall be at HBX s option repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in...

Страница 12: ...Page 12 HBX Control Systems Inc 2015 Phone 1 403 720 0029 Fax 1 403 720 0054 Email info hbxcontrols com Web www hbxcontrols com HBX Control Systems Inc 4516 112th Avenue SE Calgary AB Canada T2C 2K2...

Отзывы: