HBX THM-0600 Скачать руководство пользователя страница 4

© 2020 HBX Controls

2

INSTALLATION AND WIRING

Mounting Instructions

In order to assure proper room temperature, it is important to identify the ideal 

location of the thermostat. It should be approximately 5 feet from the floor 

and at least 1 foot from door openings on an interior wall. Avoid exposing the 

thermostat to direct sunlight, to air flows (doors, windows, etc.) as well as to 

heat sources. Ensure the cavity that the thermostat will be installed in is well 

insulated.

1   2   3  

4

1 - 2:

  External Room Sensor

3 - 4:

  Aux Sensor

    TH:

  Communication 

 

& Power from 

 ZON-0600

Use a screwdriver to gently pop the front cover off from the top of the thermostat, and 

then remove the front to expose wiring terminals.

Do not use the screwdriver on the bottom of the thermostat. This can cause damage to 

the THM-0600

External Room Thermistor

On the THM-0600, the room 

thermistor switch is located on 

the bottom left corner of the 

thermostat. 
Toggling this switch will allow the 

user to alternate between the 

built in room thermistor on the 

THM-0600, or an external room 

thermistor connected to pins 1 and 

2 on the THM-0600.

INTERNAL ROOM

EXTERNAL ROOM

Содержание THM-0600

Страница 1: ...HBX Control Systems Inc Installation Manual THM 0600 Touch Screen Programmable Thermostat Version 1 0 0 THM 0600...

Страница 2: ...cessor based controller and as such is not to be regarded as a safety limit control Please consult and install the heating or cooling appliance in accordance with the manufacturer s recommendations TA...

Страница 3: ...HM 0600 has two external sensor inputs multiple heating cooling modes and can function as a digital setpoint aquastat Some features of the THM 0600 are Dual stage heating or cooling P I D algorithm La...

Страница 4: ...nsulated 1 2 3 4 1 2 External Room Sensor 3 4 Aux Sensor TH Communication Power from ZON 0600 Use a screwdriver to gently pop the front cover off from the top of the thermostat and then remove the fro...

Страница 5: ...t a location for your system on the ThermoLinx app in settings 100 9 41 AM City App Degrees Contractor Code Key 12345 Location Time Zone Alaska 9hrs GMT Calgary C F Paci c 8hrs GMT Central 6hrs GMT Mo...

Страница 6: ...Outdoor 47 F Zone 1 LIVING ROOM Floor 70 F Target 72 F 72 0 F 10 00am Special Functions Type Heat Only Backlight View Auto Room Offset 0 F Setbacks Geo Mode Outdoor 47 F No settings will be able to be...

Страница 7: ...at and Cool Low None Air Floor 0 Special Functions ATHM 0000 Stat Type Demand Type Priority THM Mode Aux Sensor Room Offset Fancoil Setup 2 Stage Heat Low None Air Floor 0 Special Functions ATHM 0000...

Страница 8: ...Priority THM Mode Aux Sensor Room Offset Fancoil Setup 2 Cool with Heat Low None Air Floor 0 Special Functions ATHM 0000 Stat Type Demand Type Priority THM Mode Aux Sensor Room Offset Fancoil Setup 2...

Страница 9: ...erential option is set to allow a differential around the target to reduce the chances of short cycling Ex A differential of 4 F is 2 F above the setpoint and 2 F below the setpoint Special Functions...

Страница 10: ...rds internal sensor uses external Outdoor Uses external sensor to display outdoor temperature RM Ave Averages auxiliary sensor and internal sensor or optional external room sensor Floor Ave Averages a...

Страница 11: ...rd Air Floor 0 OFF Fancoil Setup Fan ON Demand Zone ON Demand Temp Average Stage Delay Damper Mode OFF OFF None 15 mins OFF Fancoil Setup Fan ON Demand Zone ON Demand Temp Average Stage Delay Damper M...

Страница 12: ...N C 1st stage is radiant and the second stage is utilizing a normally closed damper This option will require to use the next corresponding zone output to accommodate for the second stage damper This...

Страница 13: ...o default Default Setup Restores the thermostat to factory default settings or previously saved settings Selecting this option allows you to change the password No Password will remain the same Yes Th...

Страница 14: ...ch schedule event Heating Temperature Red Select the heating temperature and adjust accordingly for each schedule event Setup Menu Schedules Weekday Settings Weekend Settings Mode Away Settings Humidi...

Страница 15: ...o select a cool target when away mode is enabled Heating Cooling Target The chosen setpoint for heating and cooling zones Targets will be accessible in relation to the thermostat type chosen Mode This...

Страница 16: ...egardless of whether the thermostat is calling for heating or cooling INT This setting will set the ON OFF time for the intermittent fan Ex The fan will come on for 15 min every 2H Set Int Fan On 15 m...

Страница 17: ...s Fan Settings Backlight Degrees ON Bright F Mode Away Settings Humidity Humidity Settings Fan Settings Backlight Degrees Heat OFF ON Bright F Setup Menu Mode Away Settings Humidity Humidity Settings...

Страница 18: ...NOT CONNECT POWER HERE INT ROOM EXT ROOM HBX TH TH Fancoil R W Y G C Fancoil Heat Cool Pump DO NOT CONNECT POWER HERE GR POWER 120 17 N L 16 15 0 4 3 I TT 1 0 6 5 I TT 2 5 TH 1 10 9 6 5 12 11 6 5 14 1...

Страница 19: ...N 2 N 11 12 H ZN 3 N 13 14 H ZN 4 N 5 6 H ZONE POWER 5A 5A 5A 5A 1 2 1 1 W R Fancoil Outputs 0 8 7 I TT 3 Demand Outputs 1 18 17 1 Thermostat Signal Communication Fancoil Outputs EXT THM TH 2 TH 3 TH...

Страница 20: ...WER 120 17 N L 16 15 0 4 3 I TT 1 0 6 5 I TT 2 5 TH 1 10 9 6 5 12 11 6 5 14 13 6 5 16 15 6 2 Y G 20 19 2 X 21 2 5A 1 PUMP 1 1 2 1 1 PUMP 2 3 4 1 5A HBX ZON 0600 Zone Control N ZN 1 7 8 H N 9 10 H ZN 2...

Страница 21: ...o operate due to P I D algorithm Verify wiring on the ZON 0600 module Check priorities settings in special functions Check the mode settings Temperature not displaying correct value If it is showing d...

Страница 22: ...nually check in thermostat s Ensure zone modules are linked System is not connected to the internet Thermostat settings not all displayed on the ThermoLinx App Contact HBX Technical Support for contac...

Страница 23: ...on repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise inclu...

Страница 24: ...V1 02 Toll Free Technical Support 1 855 410 2341...

Отзывы: