HBX THM-0600 Скачать руководство пользователя страница 23

21

LIMITED WARRANTY

HBX Controls warrants each of its products to be free from defects in workmanship and materials 

under normal use and service for a period of 24 months from date of manufacture or 12 months 

from date of purchase from an HBX Authorized Dealer, if within the above documented period 

after date of manufacture.
If the product proves to be defective within the applicable warranty period, HBX on its sole 

discretion will repair or replace said product.  Replacement product may be new or refurbished of 

equivalent or better specifications, relative to the defective product.  Replacement product need 

not be of identical design or model.  Any repair or replacement product pursuant to this warranty 

shall be warranted for not less than 90 days from date of such repair, irrespective of any earlier 

expiration of original warranty period.  When HBX provides replacement, the defective product 

becomes the property of HBX Controls. 
Warranty Service, within the applicable warranty period, may be obtained by contacting your 

nearest HBX Controls office via the original Authorized Agent and requesting a Return Material 

Authorization Number (RMA #).  Proof of purchase in the form a dated invoice/receipt must be 

provided to expedite the issuance of a Factory RMA.
After an RMA number has been issued, the defective product must be packaged securely in 

the original or other suitable shipping package to ensure that it will not be damaged in transit.  

The RMA number must be visible on the outside of the package and a copy included inside the 

package.  The package must be mailed or otherwise shipped back to HBX with all costs of mailing/

shipping/insurance prepaid by the warranty claimant.
Any package/s returned to HBX without an approved and visible RMA number will be rejected and 

shipped back to purchaser at purchaser’s expense.  HBX reserves the right, if deemed necessary, 

to charge a reasonable levy for costs incurred, additional to mailing or shipping costs.

Limitation of Warranties

If the HBX product does not operate as warranted above the purchasers sole remedy shall be, 

at HBX’s option, repair or replacement.  The foregoing warranties and remedies are exclusive 

and in lieu of all other warranties, expressed or implied, either in fact or by operation of law, 

statutory or otherwise, including warranties of merchantability and fitness for a particular purpose/

application.  HBX neither assumes nor authorizes any other person to assume for it any other liability 

in connection with the sale, installation maintenance or use of HBX Controls products.
HBX shall not be liable under this warranty; if its testing and examination discloses that the alleged 

defect in the product does not exist or was caused by the purchasers or third persons misuse, 

neglect, improper installation or testing, unauthorized attempts to repair or any other cause 

beyond the range of intended use, or by accident, fire, lightning or other hazard.

Limitation of Liability

In no event will HBX be liable for any damages, including loss of data, loss of profits, costs of cover 

or other incidental, consequential or indirect damages arising out of the installation, maintenance, 

commissioning, performance, failure or interruption of an HBX product, however caused and on 

any theory of liability.  This limitation will apply even if HBX has been advised of the possibility of 

such damage.

Local Law

This limited warranty statement gives the purchaser specific legal rights.  The purchaser may also 

have other rights which vary from state to state in the United States, from Province to Province in 

Canada and from Country to Country elsewhere in the world.
To the extent this Limited Warranty Statement is inconsistent with local law, this statement shall be 

deemed modified to be consistent with such local law.  Under such local law, certain disclaimers 

and limitations of this statement may not apply to the purchaser.  For example, some states in 

the United States, as well as some governments outside the United States (including Canadian 

Provinces), may: Preclude the disclaimers and limitations in this statement from limiting the statutory 

rights of a consumer (e.g. United Kingdom);
Otherwise restrict the ability of a manufacturer to enforce such disclaimers or limitations; or grant 

the purchaser additional warranty rights which the manufacturer cannot disclaim, or not allow 

limitations on the duration of implied warranties.

Содержание THM-0600

Страница 1: ...HBX Control Systems Inc Installation Manual THM 0600 Touch Screen Programmable Thermostat Version 1 0 0 THM 0600...

Страница 2: ...cessor based controller and as such is not to be regarded as a safety limit control Please consult and install the heating or cooling appliance in accordance with the manufacturer s recommendations TA...

Страница 3: ...HM 0600 has two external sensor inputs multiple heating cooling modes and can function as a digital setpoint aquastat Some features of the THM 0600 are Dual stage heating or cooling P I D algorithm La...

Страница 4: ...nsulated 1 2 3 4 1 2 External Room Sensor 3 4 Aux Sensor TH Communication Power from ZON 0600 Use a screwdriver to gently pop the front cover off from the top of the thermostat and then remove the fro...

Страница 5: ...t a location for your system on the ThermoLinx app in settings 100 9 41 AM City App Degrees Contractor Code Key 12345 Location Time Zone Alaska 9hrs GMT Calgary C F Paci c 8hrs GMT Central 6hrs GMT Mo...

Страница 6: ...Outdoor 47 F Zone 1 LIVING ROOM Floor 70 F Target 72 F 72 0 F 10 00am Special Functions Type Heat Only Backlight View Auto Room Offset 0 F Setbacks Geo Mode Outdoor 47 F No settings will be able to be...

Страница 7: ...at and Cool Low None Air Floor 0 Special Functions ATHM 0000 Stat Type Demand Type Priority THM Mode Aux Sensor Room Offset Fancoil Setup 2 Stage Heat Low None Air Floor 0 Special Functions ATHM 0000...

Страница 8: ...Priority THM Mode Aux Sensor Room Offset Fancoil Setup 2 Cool with Heat Low None Air Floor 0 Special Functions ATHM 0000 Stat Type Demand Type Priority THM Mode Aux Sensor Room Offset Fancoil Setup 2...

Страница 9: ...erential option is set to allow a differential around the target to reduce the chances of short cycling Ex A differential of 4 F is 2 F above the setpoint and 2 F below the setpoint Special Functions...

Страница 10: ...rds internal sensor uses external Outdoor Uses external sensor to display outdoor temperature RM Ave Averages auxiliary sensor and internal sensor or optional external room sensor Floor Ave Averages a...

Страница 11: ...rd Air Floor 0 OFF Fancoil Setup Fan ON Demand Zone ON Demand Temp Average Stage Delay Damper Mode OFF OFF None 15 mins OFF Fancoil Setup Fan ON Demand Zone ON Demand Temp Average Stage Delay Damper M...

Страница 12: ...N C 1st stage is radiant and the second stage is utilizing a normally closed damper This option will require to use the next corresponding zone output to accommodate for the second stage damper This...

Страница 13: ...o default Default Setup Restores the thermostat to factory default settings or previously saved settings Selecting this option allows you to change the password No Password will remain the same Yes Th...

Страница 14: ...ch schedule event Heating Temperature Red Select the heating temperature and adjust accordingly for each schedule event Setup Menu Schedules Weekday Settings Weekend Settings Mode Away Settings Humidi...

Страница 15: ...o select a cool target when away mode is enabled Heating Cooling Target The chosen setpoint for heating and cooling zones Targets will be accessible in relation to the thermostat type chosen Mode This...

Страница 16: ...egardless of whether the thermostat is calling for heating or cooling INT This setting will set the ON OFF time for the intermittent fan Ex The fan will come on for 15 min every 2H Set Int Fan On 15 m...

Страница 17: ...s Fan Settings Backlight Degrees ON Bright F Mode Away Settings Humidity Humidity Settings Fan Settings Backlight Degrees Heat OFF ON Bright F Setup Menu Mode Away Settings Humidity Humidity Settings...

Страница 18: ...NOT CONNECT POWER HERE INT ROOM EXT ROOM HBX TH TH Fancoil R W Y G C Fancoil Heat Cool Pump DO NOT CONNECT POWER HERE GR POWER 120 17 N L 16 15 0 4 3 I TT 1 0 6 5 I TT 2 5 TH 1 10 9 6 5 12 11 6 5 14 1...

Страница 19: ...N 2 N 11 12 H ZN 3 N 13 14 H ZN 4 N 5 6 H ZONE POWER 5A 5A 5A 5A 1 2 1 1 W R Fancoil Outputs 0 8 7 I TT 3 Demand Outputs 1 18 17 1 Thermostat Signal Communication Fancoil Outputs EXT THM TH 2 TH 3 TH...

Страница 20: ...WER 120 17 N L 16 15 0 4 3 I TT 1 0 6 5 I TT 2 5 TH 1 10 9 6 5 12 11 6 5 14 13 6 5 16 15 6 2 Y G 20 19 2 X 21 2 5A 1 PUMP 1 1 2 1 1 PUMP 2 3 4 1 5A HBX ZON 0600 Zone Control N ZN 1 7 8 H N 9 10 H ZN 2...

Страница 21: ...o operate due to P I D algorithm Verify wiring on the ZON 0600 module Check priorities settings in special functions Check the mode settings Temperature not displaying correct value If it is showing d...

Страница 22: ...nually check in thermostat s Ensure zone modules are linked System is not connected to the internet Thermostat settings not all displayed on the ThermoLinx App Contact HBX Technical Support for contac...

Страница 23: ...on repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise inclu...

Страница 24: ...V1 02 Toll Free Technical Support 1 855 410 2341...