©HBS Bolzenschweiss-Systeme GmbH & Co. KG
All rights reserved – Reprinting, in whole or in part, only with the approval of the manufacturer
20
8 Components of the Power Unit
8.3
LED Display
Green
The power unit is ready for welding.
Red flashing
The capacitor battery is charged.
Red
The power unit is locked
– if battery is defective
– if thyristor is defective
– in the case of a charging malfunction (exceeding the
charging period)
Yellow
if there is electrical contact between both chucks
8.4
Light emitting diodes
(LED) on the external power supply unit
1
2
3
1 - LED LADEN (Charge)
2 - LED POL (polarity indicator)
3 - Switch
Switch position to 12 V!
LED "LADEN" lights up green
=
Normal charge
LED "LADEN" is off
=
Fully charged accumulator
LED "POL" lights up red
=
Connection has false polarity
All LEDs off
=
No charge