IT 2002 Order No BA 93-66-2201 Issue 01.06.08
39
5.9
Malfunctions and Corrective Actions
Malfunction
Possible cause
Fault finding
Corrective action
Carried out by
Primary sw itch does
not rest in position 1
Primary sw itch
defective
Check primary sw itch *)
Replace primary sw itch *)
Qualified personnel
Fuse F4 1 AF for
primary sw itch
defective
Check voltage supply of primary
sw itch *)
Replace fuse F4 1 AF *)
Qualified personnel
Primary cable defective Check primary cable for breaks *)
Replace primary cable *)
Qualified personnel
No LED display at the
front
Fuse F5 1 AF defective Check fuse F5 1 AF *)
Replace fuse F5 1 AF *)
Qualified personnel
No display
No ground connection
Check ground connection on
w orkpiece
Tighten ground connection
properly
Qualified personnel
Welding gun not
connected
Check w elding gun connection
Connect w elding gun properly
Instructed personnel
Transition resistance
(betw een stud and
w orkpiece) too high
Check material surface
Clean or grind material surface
Instructed personnel
Ground cable broken
Check ground cable *)
Replace ground cable *)
Qualified personnel
Welding gun cable
broken
Check w elding gun cable *)
Replace w elding gun cable *)
Qualified personnel
No display
Defective connecting
line of w elding gun
Check function of connecting line *) Replace connecting line *)
Qualified personnel
Welding gun trigger
button defective
Check control cable for electrical
flow w ith triggered start button *)
Replace w elding gun trigger
button *)
Qualified personnel
Control cable broken
Check control cable for electrical
flow *)
Replace control cable *)
Qualified personnel
Continuously red
display:
Display 8888
Welding sequence too
fast
Pow er unit resets automatically
Let sw itched on pow er unit cool
dow n, pow er unit resets
automatically
Instructed personnel
Welding gun does not
lift, in spite of
and
No lift adjusted
Check settings of w elding gun
Modify set parameters
Instructed personnel
Short circuit of solenoid
circuit of the w elding
gun
Check resistance value of control
cable (18 Ω to 22 Ω) betw een Pin 1
and Pin 2 *)
Replace control cable plug,
control cable, solenoid *)
Qualified personnel
Solenoid defective
Check solenoid (18
Ω to 22 Ω) *)
Replace solenoid *)
Qualified personnel
Fuse F3 4 AF defective Check fuse F3 4 AF *)
Replace fuse F3 4 AF *)
Qualified personnel
Lifting impossible
Solenoid circuit
interrupted
Check resistance value at control
cable plug (18 Ω to 22 Ω) betw een
Pin 1 and Pin 2 *)
Replace solenoid or control line *) Qualified personnel
No shielding gas
Shielding gas not
connected
Check shielding gas connection
Connect shielding gas
Instructed personnel
Shielding gas control not
enabled
Check shielding gas control for
activity
Sw itch on shielding gas control
Instructed personnel
Shielding gas valve
defective
Check shielding gas valve *)
Replace shielding gas valve *)
Qualified personnel
Actions marked with *) must only be carried out by qualified
electricians!
If none of the actions is successful, please contact our service
department.
Содержание 93-66-2201
Страница 1: ...IT 2002 Power Unit 93 66 2201 Operating Manual...
Страница 8: ...viii IT 2002 Order No BA 93 66 2201 Issue 01 06 08...
Страница 45: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 45 Power unit type IT 2002 93 66 2201...
Страница 47: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 47 Basic set up complete IT 2002 88 16 268...
Страница 49: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 49 Front assembly complete IT 2002 88 16 269023...
Страница 53: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 53 Country module USA complete IT 2002 88 17 930...
Страница 56: ...56 IT 2002 Order No BA 93 66 2201 Issue 01 06 08 8 3 Circuit Diagram...
Страница 65: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 65 Service Support...
Страница 69: ......