36
IT 1002 Order No. BA 93-66-1202 Issue 01.06.08
5.6.4 Library Mode
In the library mode, you can call up and modify charging voltages, depending on stud
diameter (UD/Pins).
Simultaneously press both arrow keys of welding time (
shorter
,
longer), for
about one second. The display welding time shows 0-06 (06 means the set
welding current and welding time for stud diameter of 6 mm).
You can pre-select the stud diameter (6 mm - 12 mm) with both arrow keys
( shorter, longer). After about 3 seconds the display (
) jumps onto the
pre-selected charging voltage and the display (
) onto the pre-selected
welding current.
In addition, you can modify the welding time and welding current individually by
pressing the arrow keys (as described above).
If you are working with shielding gas, different welding parameters for stud
diameters (from 6 mm to 12 mm) are available in library mode.
5.6.5 Electrode Mode
You can switch the power unit to electrode mode.
Simultaneously press both arrow keys (welding current
lower
higher) for
about one second. The display Welding time shows EL.
You can pre-select the welding current (from 50 to 400 A) with both arrow keys
( lower higher).
If you touch the work piece with the electrode, the power unit is switched on.
If you switch the power unit off and on, the power unit is
automatically reset to stud welding.
Содержание 93-66-1202
Страница 1: ...IT 1002 Power Unit Ceramic Gas Version 93 66 1202 Operating Manual...
Страница 8: ...viii IT 1002 Order No BA 93 66 1202 Issue 01 06 08...
Страница 51: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 51 Power unit IT 1002 93 66 1202...
Страница 53: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 53 Front plate complete IT 1001 IT 1002 88 13 163...
Страница 55: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 55 Supply module complete IT 1002 88 17 997...
Страница 57: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 57 Shielding gas module IT 1001 IT 1002 88 13 167...
Страница 59: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 59 Terminal plate complete IT 1002 88 18 013...
Страница 61: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 61 Power unit complete IT 1002 88 17 929...
Страница 62: ...62 IT 1002 Order No BA 93 66 1202 Issue 01 06 08 8 3 Electrical Circuit Diagram...
Страница 71: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 71 Service Support...
Страница 75: ......