20
IT 1002 Order No. BA 93-66-1202 Issue 01.06.08
3.5
Shielding Gas Connection
Observe the standards (see appendix) when handling the
shielding gas bottles.
Connect the gas hose of the shielding gas bottle to the gas inlet of the power
unit.
Connect the gas hose of the welding gun to the gas outlet.
Set the flow meter of the shielding gas bottle to 8 - 16 liters/min.
Minimum flow rate for stud welding with shielded gas is 8 l/min.
A gas mixture of 82% Argon (Ar) and 18% carbon dioxide (CO
2
) is mainly used for stud
welding.
3.6
Change Working Place
Switch off the power unit. In this way, you avoid any risk of
electrical shock.
When you move your workplace, disconnect the welding gun and the ground
cables from the power unit. Proceed in reversed sequence as described in
sections 3.2, 3.3, 3.4 and 3.5.
After changing the workplace, check the welding gun and the ground cables for
possible damage or missing components.
Содержание 93-66-1202
Страница 1: ...IT 1002 Power Unit Ceramic Gas Version 93 66 1202 Operating Manual...
Страница 8: ...viii IT 1002 Order No BA 93 66 1202 Issue 01 06 08...
Страница 51: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 51 Power unit IT 1002 93 66 1202...
Страница 53: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 53 Front plate complete IT 1001 IT 1002 88 13 163...
Страница 55: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 55 Supply module complete IT 1002 88 17 997...
Страница 57: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 57 Shielding gas module IT 1001 IT 1002 88 13 167...
Страница 59: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 59 Terminal plate complete IT 1002 88 18 013...
Страница 61: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 61 Power unit complete IT 1002 88 17 929...
Страница 62: ...62 IT 1002 Order No BA 93 66 1202 Issue 01 06 08 8 3 Electrical Circuit Diagram...
Страница 71: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 71 Service Support...
Страница 75: ......