©HBS Bolzenschweiss-Systeme GmbH & Co. KG
All rights reserved – Reprinting, in whole or in part, only with the approval of the manufacturer
30
11 Connection
11 Connection
First prepare your place of work.
Read and observe here
point 10 "Preparing place of work and welding
process"
.
Electric shock hazard
Leave the power unit switched off during connection of the connecting
leads.
In this way you can avoid any unintentional starting of the welding process.
Secure the cables.
Strong magnetic fields are generated during the welding process that can
lead to whipping of the cables. This can cause the cables to come out of
the plug sockets.