Electrical connection
PW27
A3010-2.0
HBM: public
13
4.3
Shortening the cable
As the load cell connection uses a six‐wire configuration,
you can shorten the 6‐wire load cell cable without this
changing the load cell calibration.
4.4
Cable extension
Use shielded, low‐capacitance measurement cables only
for extension. Ensure that connection is perfect, with a
low contact resistance.
The cable of a six‐wire load cell can be extended with a
cable of the same type.
4.5
Parallel connection
Only single point load cells with an aligned output
(nominal (rated) sensitivity and output resistance) are
suitable for parallel connection. This option is not
available with type PW27 single point load cells.
4.6
EMC protection
Electrical and magnetic fields often induce interference
voltages in the measuring circuit. Therefore:
S
Use shielded, low‐capacitance measurement cables
only (HBM cables fulfill both conditions)
S
Do not route the measurement cables parallel to
power lines and control circuits. If this is not possible,
protect the measurement cable, in rigid steel conduits,
for example
Содержание PW27
Страница 1: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Français PW27 ...
Страница 3: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Français PW27 ...
Страница 20: ...Dimensions 18 A3010 2 0 HBM public PW27 ...
Страница 21: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Français PW27 ...
Страница 38: ...Abmessungen 18 A3010 2 0 HBM public PW27 ...
Страница 39: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Français PW27 ...
Страница 55: ...Dimensions PW27 A3010 2 0 HBM public 17 ...