Output of measured values
ML77B
A00760_09_E00_00
HBM: public
43
4
Byte
2
Byte
1
Byte
0
Status
meas. val. subchannel 2
8
Byte
2
Byte
1
Byte
0
Status
meas. val. subchannel 3
:
:
Byte
2
Byte
1
Byte
0
Status
meas. val. subchannel n
Notice
If the measuring rate of the communication processor is set to a value below 60
Hz, an average filter will be activated automatically.
Thereby the lowest 2 bits of the measured value will always be set to 0 (only
24-bit mode)!
In 16-bit mode the measured values of the subchannels are represented in the
memory as follows:
Byte address in PLC
memory
MSB
LSB
0
Byte 1
Byte 0
meas. val. subchannel 1
2
Byte 1
Byte 0
meas. val. subchannel 2
4
Byte 1
Byte 0
meas. val. subchannel 3
:
:
Byte 1
Byte 0
meas. val. subchannel n
The measuring status is always set to zero in 16-bit mode.
Notice
If the ML77B uses output data, there always has to be at least one measuring
channel in the configuration!