background image

3

Content

A2887

2.0 en/de

Content

Page

1 Introduction

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1.1 Starting up / recommended procedure

. . . . . . . . . . . . . . . . . . . . . . . . 

2 Installing the software

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2.1 Installing catman

Starter

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2.2 Drivers for catman

Starter

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

3 Connecting modules and transducers

. . . . . . . . . . . . . . . . . . . . . . . . . 

3.1 Transducer connection options

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

3.2 Connecting and setting up the system

. . . . . . . . . . . . . . . . . . . . . . . . 

3.3 Active USB HUB connection (x4)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

3.3.1 Plug-in sequence

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4 Module voltage supply

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4.1 Connection to a PC (USB input)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5 Configuration and measurement with catman

Starter

10 

. . . . . . . . . . 

5.1 Before sensor assignment

12 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5.2 Assigning sensors

12 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5.3 Setting filters and data rates

12 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5.4 Opening the “Visualization setup” dialog

13 

. . . . . . . . . . . . . . . . . . . . . . 

Содержание espressoDAQ DQ401

Страница 1: ...DQ401 DQ430 DQ809 A2887 2 0 en de Quick Start Guide Kurzanleitung...

Страница 2: ...Dokument verwendeten Warenzeichen oder Marken weisen nur auf das jeweilige Produkt oder den Inhaber des Warenzeichens oder der Marke hin HOTTINGER BALDWIN MESSTECHNIK GMBH erhebt damit keinen Anspruch...

Страница 3: ...d transducers 6 3 1 Transducer connection options 6 3 2 Connecting and setting up the system 6 3 3 Active USB HUB connection x4 7 3 3 1 Plug in sequence 8 4 Module voltage supply 9 4 1 Connection to a...

Страница 4: ...ressoDAQ operating manual PDF document on the accompanying Sy stem CD This guide shows you How to use the espressoDAQ module to connect up to 4 espressoDAQ modules to a PC via a USB HUB How to start u...

Страница 5: ...ption and contains the catman Starter Lab View driver and library and Net Com API programs Put the installation CD in the CD slot compartment The installation software should start automatically If th...

Страница 6: ...can connect the following transducers to espressoDAQ espressoDAQ amplifier Measurand DQ401 DQ430 DQ809 Strain gage full bridge X Strain gage half bridge X Voltage X X Current X Thermocouple X Temperat...

Страница 7: ...active USB hub recommended by HBM This allows a small and fully synchronized system to be set up Multi module operation max 4 modules DQ 401 DQ 809 DQ 430 Transducer for voltage and current sources A...

Страница 8: ...ower supply 2 Connect the PC and the other modules USB USB USB USB Power supply Standard USB cable 1 USBHUB 4A 1 KAB286 2 1 2 Abb 3 4 USB HUB connection with 4 modules Following the correct connection...

Страница 9: ...V at max 500 mA via the USB cable One module can be supplied via the PC s USB socket in this way Pin assignment for the USB connection cable PIN Designa tion Color code 1 5 V rd 2 Not in use 3 Not in...

Страница 10: ...procedure for working with catmanStarter Launch catman Starter A welcome screen appears containing general information about catman Starter The dialog can be deactivated for the next call Click Next S...

Страница 11: ...ues Zero setting Measurement channel activation Sensor database Setup Start Assign the connected sensors to channels Allocate unique channel names Mark the channels to be set to zero and run a zero ad...

Страница 12: ...gnment The current measured value is displayed when Live measured value is acti vated Deactivate the Live measured values checkmark 2 Then Run a zero adjustment Press the zero button 3 5 2 Assigning s...

Страница 13: ...the Visualization setup dialog Press the Start button top left 7 You can select the different visualization elements here Automatic visualization The combination of Automatic and pressing the Use def...

Страница 14: ...different formats for later analysis Manual visualization Alternatively visualization can also be set up manually by clicking on the Vi sualization tab 1 2 1 2 Visualization Visualization objects Acti...

Страница 15: ...Scope Panel press Automatic and Use default setting This concludes the measurement You now have more than one possible way to continue 1 Perform a new measurement 2 Call a measurement project Tip Furt...

Страница 16: ...schlie en 19 3 1 Aufnehmeranschluss M glichkeiten 19 3 2 Anschlie en und Einrichten des Systems 19 3 3 Anschluss des aktiven USB HUBs 4fach 20 3 3 1 Ansteckreihenfolge 21 4 Spannungsversorgungder Modu...

Страница 17: ...espressoDAQ PDF Dokument auf beiliegender System CD Diese Anleitung zeigt Ihnen wie Sie mit dem espressoDAQ Modul bis zu 4 espressoDAQ Module ber einen USB HUB an einen PC anschlie en k nnen wie Sie d...

Страница 18: ...e catman Starter Lab View Treiber und Bibliothek sowie Net Com API Schieben Sie die Installations CD in das CD Slot Fach Die Installationssoftware sollte automatisch starten Passiert dies nicht Starte...

Страница 19: ...odul k nnen Sie an espressoDAQ folgende Aufnehmer anschlie en espressoDAQ Messverst rker Messgr e DQ401 DQ430 DQ809 DMS Vollbr cke X DMS Halbbr cke X Spannung X X Strom X Thermoelement X Temperaturmes...

Страница 20: ...al vier espressoDAQ Module angeschlossen werden Damit l sst sich ein kleines voll synchronisiertes System aufbauen Mehrmodul Betrieb max 4 Module DQ 401 DQ 809 DQ 430 Aufnehmer f r Spannungs und Strom...

Страница 21: ...e en 4 PC und weitere Module anschlie en USB USB USB USB Netzteil Standard USB Kabel 1 USBHUB 4A 1 KAB286 2 1 2 Abb 3 8 USB HUB Anschluss mit 4 Modulen Das Anschlie en in der richtigen Reihenfolge ver...

Страница 22: ...wird das Modul mit 5 V bei max 500 mA versorgt Damit kann ein Modul ber die USB Buchse des PCs versorgt werden Anschlussbelegung USB Anschlusskabel PIN Benennung Ader farbe 1 5V rt 2 Nicht belegt 3 Ni...

Страница 23: ...beiten mit catmanStarter Starten Sie catman Starter Es ffnet sich ein Begr ungsbildschirm mit allgemeinen Informationen zu catman Starter F r den n chsten Aufruf kann der Dialog deaktiviert werden kli...

Страница 24: ...sskan le Live Messwerte Nullstellen Messkanal aktivieren Sensordatenbank Einrichten Start Weisen Sie den Kan len die angeschlossenen Sensoren zu Vergeben Sie eindeutige Kanalnamen Markieren Sie die Ka...

Страница 25: ...sind 5 1 Vor der Sensorzuweisung Der aktuelle Messwert wird angezeigt wenn Live Messwert aktiviert ist den Haken Live Messwerte 2 deaktivieren Anschlie end Nullabgleich ausf hren dr cken der Nulltast...

Страница 26: ...erung einrichten ffnen Dr cken des Start Buttons oben links 7 Hier k nnen Sie unterschiedliche Visualisierungselemente ausw hlen Visualisierung automatisch Mit der Kombination Automatisch und dr cken...

Страница 27: ...k nnen in verschiedenen Formaten f r sp tere Analysen abgelegt werden Visualisierung manuell Alternativ kann die Visualisierung auch manuel eingerichtet werden durch klick auf das Register Visualisie...

Страница 28: ...ualisierung einrichten aktiviert Seite 26 Zum Aktivieren des 4 geteilten Scope Panels Automatisch und Vorein stellung verwenden dr cken Hiermit ist die Messung beendet Sie haben nun mehrere M glichkei...

Страница 29: ...29 Konfigurieren und Messen mit catmanSTARTER A2887 2 0 en de...

Страница 30: ...30 Konfigurieren und Messen mit catmanSTARTER A2887 2 0 en de...

Страница 31: ...31 Konfigurieren und Messen mit catmanSTARTER A2887 2 0 en de...

Страница 32: ...ger Baldwin Messtechnik GmbH All rights reserved All details describe our products in general form only They are not to be understood as express warranty and do not constitute liability whatsoever nde...

Отзывы: