Page 

Assembly Instructions  M8098-EN 

 

Spare part heat sensor (O/ID T25603) 

 

 

  

Purpose 

  

Replacement of heat sensor (BT 1, BT 2.x) 

  

 

  

Precondition 

      

 

WARNING! 
Danger for unauthorized persons! 

Conversion work may only be carried out by 
specialist staff who have been trained accordingly. 

Therefore: 
–  Keep unauthorized persons away from the work 

area. 

   

 

   

 

NOTE! 

Knowledge of the Instruction Manual is a 
precondition for carrying outconversion work on the 
unit. 

   

 

  

Procedure 

      

 

DANGER! 
Danger to life caused by electric current! 

Touching conductive parts causes a direct danger 

to life. 

Therefore: 
–  For all work on the electrical system, for 

maintenance, cleaning or repair work, 
disconnect from the mains or disconnect all 
phases of the external power supply and secure 
them against being switched on again. Check 
unit is isolated from power supply. 

   

 

  

 

 

WARNING! 
Danger of crushing due to rolling away or 
tipping 

With an uneven floor or when the castors are not 
locked, there is a danger that the unit tips over or 
rolls away causing crushing. 

Therefore: 

–  Only install the unit on an even floor. 
–  Ensure that the castors are locked. 

   

 

Содержание M8098

Страница 1: ...outconversion work on the unit Procedure DANGER Danger to life caused by electric current Touching conductive parts causes a direct danger to life Therefore For all work on the electrical system for maintenance cleaning or repair work disconnect from the mains or disconnect all phases of the external power supply and secure them against being switched on again Check unit is isolated from power sup...

Страница 2: ...cated with the symbol 2 Main switch off remove the plug from the mains and empty the unit 3 Remove control cable to ext flow rate meter Flow 5 4 Detach the hexagon screw and remove ext flow rate meter Flow 5 Fig 1 Front side of the evaluation unit Fig 2 Rear side of the evaluation unit 5 Proceed as follows in order to remove the cover of the evaluation unit Remove screws Label 1 Fig 1 Detach screw...

Страница 3: ...placement temperature sensor return line BT 2 x Disassemble screws Label 6 Fig 4 and remove cover 7 Replace temperature sensor main line BT 1 or return line BT 2 x while proceeding as follows Fig 5 Flow 5 side view from the right Disconnect temperature sensor BT 1 BT 2 x at the flow rate measuring board DFM 51 A 9 x Disassemble temperature sensor BT 1 BT 2 x Fig 5 Transfer label of temperature sen...

Страница 4: ...er to attach the covers Fig 8 Flow 5 with ball valve Fig 9 Flow 5 view from below Attach insulation and cover plate mount screws Label 5 Fig 8 Attach insulation and cover plate mount screws Label 4 Fig 8 If present install shut off valve OUT 1 and 4 Label 3 Fig 8 Only in the event of a replacement temperature sensor return line BT 2 x Attach cover plate and mount screws Label 6 Fig 9 10 Connect co...

Страница 5: ... sensor return line ext Proceed as follows in order to calibrate 1 8 if necessary the temperature sensor With a constant deviation set parameter Sensor offset under Service Calibration Temperature With a linear deviation set parameter Sensor asc cor under Service Calibration Temperature Fig 11 Sensor calibration during modular operation Operation Modular 16 Proceed as follows if necessary calibrat...

Страница 6: ... EN M8098 EN 2018 03 6 6 Parts list Pos Description O ID Pcs 01 Heat sensor Pt 1000 0 53 m T24888 1 02 Assembly instructions German M8099 DE 1 03 Assembly instructions English M8099 EN 1 04 Assembly instructions French M8099 FR 1 ...

Отзывы: