Assembly Instructions M8095-EN
M8095-EN 2020-09
3/13
Product group Thermo-5
1.
Switch off master switch and disconnect from mains supply.
2.
Loosen the screws in the front panel and hinge it down.
3.
Proceed as follows in order to remove the GIF-51 (A 4):
Remove all connectors.
Remove the flexes that are led through current transformers
(TA 1.1, 1.2, 1.3) at the contactor or terminal:
Cable routing
(from
to)
Unit type
KM 1
X 86
Housing size 1+2, 8 kW, 400/460 V
KM 1
XT 2
Housing size 1, 8 kW, 210 V
KM 1
XT 2
Housing size 2, 16 kW, 400/460 V
XT 2
V x.x
Housing size 2, 8+16 kW, 210 V
KM 1
FS 4
Housing size 3, Pump type G_, L_, 6_, 8_
Remove the screws on the sides of the board.
On oil unit unplug the printed circuit board level measuring
(A 10).
Fig. 1: Cable routing
Fig. 2: Cable routing housing size 3 pump
G_, L_, 6_, 8_
4.
Proceed as follows in order to fit the new GIF-51 (A4):
On oil unit insert the printed circuit board level measuring (A 10)
into new GIF-51.
Fit the GIF-51 and fix with the screws.
Route the wires through current transformers (TA 1.1, 1.2, 1.3)
and connect them (
Cable routing
(from
to)
Unit type
KM 1
X 86
Housing size 1+2, 8 kW, 400/460 V
KM 1
XT 2
Housing size 1, 8 kW, 210 V
KM 1
XT 2
Housing size 2, 16 kW, 400/460 V
XT 2
V x.x
Housing size 2, 8+16 kW, 210 V
KM 1
FS 4
Housing size 3, Pump type G_, L_, 6_, 8_
For housing size 3, pump type G_, L_, 6_, 8_ additionally lead
wires from cable connector (X 63) through current transformer
(TA 1.2) and connect to contactor KM 4/A1, KM 5/A1 (
Connect all connectors.
Connect main pump cable (X 62/X 64):
Voltage 200
–220 V
Slot X 62 (triangle)
Voltage 380
–480 V
Slot X 64 (star)
A 10
from
to
X 62
X 64
TA 1.3
TA 1.2
TA 1.1
KM 4/KM 5
X 63
TA 1.2