HazSim Pro 1.0 Скачать руководство пользователя страница 10

  9

 

 

3.3 Controlling the Meter 

Use the arrows to change the readings on the HazSim meter. Single arrow for small 
increment, double arrow for large increment. ‘Norm’ returns the individual gas to it’s 
normal reading. Norm-All returns ALL ‘gases’ to normal.  
To change meters entirely, simply select the change meter icon on the meter control screen 
and the previous list of meters will show. Select a new meter from the list and the HazSim 
will change to the selected meter.  

3.4 Asking Questions 

With the HazSim Pro 1.0, instructors are able to send questions to the student via the 
HazSim handheld in real time. Once received, the student can answer the question via 
touch screen on the HazSim handheld unit. The instructor can utilize standard questions 
pre-loaded on the HazSim Server or create custom question and answers​. 
Because scenarios are dynamic, instructors should know the desired answer before giving 
the question. The system does not have the ability to know all of the variables in the 
scenario that would complete a correct answer. For example, a student may be asked, “Are 
you wearing the appropriate PPE?” while entering a toxic atmosphere. The correct answer 
would rely on what level of dress the student is wearing, thus the system will not 
automatically know. The same question, “Is your PPE correct?” may be used for a desired 
YES answer when they are donning the correct PPE, OR as an incorrect, or NO answer, if 
they are in the wrong PPE. The instructor must select the question that corresponds with 
the desired answer or intended plan for the drill.  

Send a Question 

To send a question touch ‘Select Question’ and the question pop up window will open 
labeled Select Question File.  The select question file is opened .  Select the desired 
question and either double click or choose question.  Once sent the question will appear on 
the HazSim meter and the meter display will show there is a question awaiting an answer. 
Once the student answers their selection will show on the meter control screen.  If a 
question is sent and you decide to change to another question you can cancel the question 
by selecting cancel question and the question will disappear from the HazSim handheld 
unless already answered by the user. 
To send a question: 

Press ‘Select Question’.  The first time this button is selected it will open the ‘select 
question file’ list which is the databases of each type of question.  Once the 
database is selected a group of questions related to that subject will appear in a 
new box. 

Содержание Pro 1.0

Страница 1: ...HazSim Pro 1 0 User Manual 3 20 2019 V1 2 HazSim LLC PO Box 3642 Palos Verdes CA 90274 310 997 9030 ...

Страница 2: ...erver 2 1 3 HazSim Handheld 2 2 Turning Off the System 2 3 Charging the HazSim Handheld 3 Operating the System 3 1 Selecting a Meter 3 2 Meter Control Buttons 3 3 Controlling the Meter 3 4 Asking Questions 4 Advanced Features 4 1 Editing and Creating Alarms 4 2 Editing and Creating Questions 4 3 Operating Multiple Handhelds 5 Maximizing Range 6 Troubleshooting ...

Страница 3: ...er Convertible laptop or tablet with touch screen is used by the instructor to control the HazSim handheld meter If your system is the convertible laptop it can be used with the keyboard in laptop mode or flipped closed and used as a tablet for more portability When turned on the server should automatically boot up to the HazSim program In instances where the server may have not been shut down pro...

Страница 4: ...ll work up to a one thousand foot range which is about the length of three football fields depending on obstructions see Section 5 Maximizing Range The LAN network will be found as HazSim Extended which will NOT allow access to the internet this network is for the HazSim training system only Figure 03 HazSim LAN with screw in antenna LAN should be placed in a high position for best range results ...

Страница 5: ... 04 HazSim Pro Handheld with Four Gas Meter shown 2 Powering Up the System Included with each system is a laminated Getting Started Guide which is an abbreviated version of these instructions Also refer to the training video on setting up the system 2 1 Startup Sequence 2 1 1 STEP ONE Set up the LAN Connect included CAT5 Cable to POE Power Over Ethernet port on the POE Adapter black box DO NOT con...

Страница 6: ...ly connect to the HazSim Extended network 2 1 3 STEP THREE Turn on the HazSim handheld by pressing and holding the power button Figure 06 located on the top of the HazSim for at least 2 seconds Wait for the startup to complete approximately 30 seconds When the device has completed startup it will automatically connect to the HazSim server This connection will trigger a popup window on your HazSim ...

Страница 7: ...System Once you have set up and powered on the LAN server and handheld it s time to start training 3 1 Selecting a Meter Once connected the HazSim Server will initially show the Meter Selection Window Figure 07 This is where you select which meter you will use for training If the Meter Selection Window does not appear after start up refer to Section 6 Troubleshooting Using the drop down menu Figur...

Страница 8: ...screen or cursor the instructor can manipulate the values shown on the HazSim handheld up or down accordingly to create a simulated training environment Figure 10 Instructor Meter Control Window vs readings shown on HazSim Note when CO is changed to 24 the HazSim reflects 24 ppm ...

Страница 9: ...ading levels Select Question Used to verify student understanding during training The first time this is selected you will be prompted to select the Question File which is a database with sets of questions on specific topics Change Questions List Used to select via drop down which questions list group Choices include Basic Advanced Radiation Confined Space and more Each list has approximately ten ...

Страница 10: ...The correct answer would rely on what level of dress the student is wearing thus the system will not automatically know The same question Is your PPE correct may be used for a desired YES answer when they are donning the correct PPE OR as an incorrect or NO answer if they are in the wrong PPE The instructor must select the question that corresponds with the desired answer or intended plan for the ...

Страница 11: ...azSim Pro 1 0 is delivered with a complement of standard questions sorted in different question databases Switch question databases with the Change Questions list button on the meter control screen To add a new question select Edit Question and a new window will open to add or remove questions Fill in the desired question and desired answer options Select Edit Questions Select Database from list a...

Страница 12: ...dit window and a new alarm field will be added to the list starting from the bottom The default new alarm will be for O2 Change the data fields for each with the first window the gas the next the low alarm zero for all but O2 and the high alarm reading then close the window To remove an alarm select Remove Alarm and the alarms will be deleted one by one starting from the bottom Any alarm already i...

Страница 13: ...box i e HCN For anything other than Oxygen leave the 0 0 zero in the middle box Edit the right box to the desired alarm level Closing the window will save what was entered Remove alarm will remove each alarm from the bottom of the list up Check with HazSim if alarm is correct before using in training ...

Страница 14: ...eries Handheld batteries are designed to be quick charged 8 to 12 hours prior to training but do not hold a charge during storage so require charge before use The batteries are NOT user serviceable Contact HazSim for repair or replacement Attempting to change the battery in HazSim Handheld VOIDS all Warranty Connection Issues If the system does not connect review the quick set up section If no con...

Страница 15: ...ning session In general if the instructor can see the LAN and the LAN can see the students with the HazSim the range should be good If you are training in an area with thick concrete or steal several feet below grade reinforced vaults or reinforced ships I LAN in raised position Raising the LAN to a height which has an overview of the training ground can greatly extend the range of the HazSim syst...

Страница 16: ...azSim screen shows Logo HazSim is on but not connected to server Alarm sounds upon connection Alarm value was set within normal range after alarm edit Buzz Meter button pressed If recent change to Alarm Edit check the settings Meter Select window showing on server System connected waiting for user to select a meter type Meter Select window not showing on server Server not connected check lan setti...

Отзывы: