background image

www.haze

base

.com

15

English

9. pump characteristics

Under SETTINGS -> SETTINGS 2 -> MODE the pump characteristic can be adjusted. There are four different 

characteristics available.

1. PULSE - This mode means that the pump always mists at the set value. It is not regulated down, when rea-

ching the shutdown temperature, the pump is turned off

2. EXTENDED - This mode also starts with the set pump value. If the temperature in the heating element drops, 

the pump is slightly downshifted. This increases the fog duration without a drastic drop in emissions. When the 

shutdown temperature is reached, the pump is switched off.

3. FLOOD - This mode is similar to the EXTENED mode, except that the pump is downshifted until the amount 

of continuous fog is reached. The machine starts with a high output and then goes into the continuous mist 

condition.

4. CONTINUOS - Here, the pump is limited to 30% to ensure a uniform duration fog.

Under SETTINGS -> SETTINGS 2 -> MODE the pump characteristic can be adjusted.

The fine adjustment is used to adjust the amount of mist. You can adjust the pump curve up or down by 5%. If 

you have several machines of the same type, you can adjust the output quantity of both machines. The machi-

nes are not exactly the same in terms of production output. Furthermore, aging processes can influence the 

output quantity. With this adjustment method you can compensate for the differences.

Содержание base-prime

Страница 1: ...operation manual base prime Stargarder Straße 2 30900 Wedemark Germany Phone 49 5130 37 10 05 Fax 49 5130 37 10 06 E Mail info hazebase com contact www hazebase com ...

Страница 2: ...1 Overview operating modes 6 4 2 Manual mode 7 4 3 Operation via DMX 8 4 4 Operation via analog 9 4 5 Betrieb über Ethernet 10 4 6 Operation via timer 11 4 7 Setting up IP address 12 5 Adjust the screen brightness 13 6 Set the duration of the screensaver 13 7 Device information 14 8 Reset factory settings 14 9 pump characteristics 15 10 More Settings 16 11 Scope of Delivery 17 12 Technical specifi...

Страница 3: ...lycol is a chemical alcohol and burns with a slightly bluish almost invisible flame Never point the fog at strong sources of ignition like fire or pyrotechnic effects During operation small amounts of hot fluid drops may emerge Therefore you should make sure that these do not become a danger to anyone Do not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot o...

Страница 4: ...ons located on an non flammable place or surface Well ventilated with fog free air keeping the ambient operating temperature between 5 C and 45 C and the relative air humidity below 80 3 2 Devicelabeling A Nozzle for fog emission B RJ45 Ethernet socket for Artnet and sACN C 5 pin XLR DMX input and output DMX512 D 3 pin XLR analog input E PowerCon power connection F Touchscreen for operating B A C ...

Страница 5: ... From the moment the temperature does not fog the display lights otherwise NOT READY is displayed The shutdown and control characteristics now depend more on the temperature allowing for longer fogging A table with exact fogging time can be found in chapter 12 If the heating element is warmer than 250 C it can be fogged up to 30 If fogging takes place at a higher level and the heating element cool...

Страница 6: ...e main menu of the base prime M R T P O S N Q U L Analog Input Display Shows the selected mode and current voltage P Ethernet display Indicates which protocol was selected and whether the base prime is controlled via Ethernet M Indicates if the machine is at operating tempe rature The Ready indicator flashes when the lowest temperature at which misting can be started is reached NOT READY is displa...

Страница 7: ... be changed via and as well as by pressing on the center Then a keyboard will appear and the value can be entered A change in the pump value is possible both before and during the misting pro cess It is important to know that the pump characteristics can influence the ejected amount of fog This also means that at selected 100 possibly less fog can be generated Further information can be found in t...

Страница 8: ...e queried Select the button DMX in the main menu or under SETTINGS DMX The right screen appears Here the DMX address can be entered With DMX ADDRESS SAVE the DMX ad dress is saved BACK will take you back to the main menu without saving Channel Value Description 1 0 255 Pumpenwert Channel Value Description 1 0 255 pumpvalue 2 pumpmode 0 63 Continous 64 127 Flood 128 191 Extended 192 255 Impulse It ...

Страница 9: ...RECT This mode is for example XLR remote with input voltages bet ween 1 and 10V which can be selected via the button DIRECT 10V input voltage correspond to the full set pump value 1V cor responds to 1 of the pump value If the base prime is activated in latched mode it must first be deactivated in latched mode Switching is possible but the machine can not be deactivated 2 LATCHED In Latched mode th...

Страница 10: ... According to the standards for DMX and ARTNET a universe consists of 512 DMX channels A subnet consists of 16 universes and a network is 16 subnets There are 128 networks sACN Select sACN With PROTOCOL SAVE you save your settings and with BACK you get back to the previous screen With MODIFY you have the possibility to adjust the universe Press the CE key on the keyboard screen and then enter the ...

Страница 11: ... first row on the right ON TIME and OFF TIME are set Values from 0 to 60 can be set here The timer can be started both MANUELY and via the REMOTE Pressing the TRIGGER button switches between these modes Furthermore a single pulse can be programmed in the second line Press the ONE PULSE button to activate or deactivate this mode Also use the AUTO START setting if you want to turn on the timer immed...

Страница 12: ...sign your device an IP address and a subnet mask from a DHCP server on your network Once you have selected STATIC you can set the values using MODIFY and the right hand keyboard If necessary ask your network administrator which network address you should use For networks where the IP address and subnet mask are to be used according to the ARTNET standard first set the mode to STATIC and then press...

Страница 13: ...With BRIGHT SAVE they save their attitude BACK will take you to the previous screen without saving settings 6 Set the duration of the screensaver To set the screen saver of the base prime click on in the main menu SETTINGS NEXT SETTINGS 2 SCREENSAVER Here you can set the duration of the screensaver Press or to change the value With SAVE they save their attitude BACK will take you to the previous s...

Страница 14: ...mputer and an existing network connection between PC and de vice is needed Please refer to the Hazebase website for new firmware versions and procedures BACK will take you to the previous screen without saving settings 8 Reset factory settings To restore the default settings of the base prime click on in the main menu SETTINGS NEXT SETTINGS 3 FACTORY RESET Here you can restore the factory settings...

Страница 15: ...ump is switched off 3 FLOOD This mode is similar to the EXTENED mode except that the pump is downshifted until the amount of continuous fog is reached The machine starts with a high output and then goes into the continuous mist condition 4 CONTINUOS Here the pump is limited to 30 to ensure a uniform duration fog Under SETTINGS SETTINGS 2 MODE the pump characteristic can be adjusted The fine adjust...

Страница 16: ...has a standby mode This can be found under SETTINGS SETTINGS 2 STANDBY After data is no longer received via DMX Artnet or sACN the ma chine goes into standby mode To do this the above screen will be displayed for 10 seconds After the time has elapsed the HE is switched off and the screen below is displayed With Back you can cancel the process with STANDBY you can switch directly to standby mode In...

Страница 17: ...uid 12 Technical specifications base prime Procedure vaporizing fog generator Leistung 1500 Watt US Version 3100Watt Europe Version Supply voltage 230V 50Hz Heating time 15min Control options DMX Art Net sACN analog 0 10V manual timer operation Weight 16 5 kg 35 lbs Fog duration Fog Value Impulse Mode Extended Mode 100 22s 55s 90 40s 76s 80 55s 95s 70 89s 128s 60 112s 176s 50 167s 347s 40 378s 30 ...

Страница 18: ...unauthorized persons and or if spare parts are used which are nor approved by us The right of guarantee service is also lost if fluids other than Original hazebase fluids have been used or if units are sent to us with full fluid bottles Also non compliance with the instructions in this manual or mistakes by incorrect handling treating of the machine will lead to a loss of guarantee and also any fa...

Страница 19: ...www hazebase com 19 English 14 Contact hazebase Founder Uta Raabe Stargarder Straße 2 30900 Wedemark GERMANY Tel 49 0 5130 371005 Fax 49 0 5130 371006 info hazebase com www hazebase com ...

Отзывы: