USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Page 5 of 12 

Spa Blower 

ISSPB   Rev-A 

 

 

 

 

WARNING

 – To Reduce the risk of Entrapment Hazards: 

When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump 
must be installed.  Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet 
(3’) [0.91 meter] apart, as measured from near point to near point. 

Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. 

Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 

Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely 
attached. 

Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. 

In addition to two or more suction outlets per pump installed in accordance with latest APSP standards and CPSC 
guidelines, follow all national, state, and local codes applicable. 

Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. 

 

WARNING

 

– Hazardous Pressure.

  Pool and spa water circulation systems operate under hazardous 

pressure during start-up, normal operation, and after pump shut-off.  Stand clear of circulation system equipment 
during pump start-up.  Failure to follow safety and operation instructions could result in violent separation of the 
pump housing and cover due to pressure in the system, which could cause property damage, severe personal injury, 
or death.  Before servicing pool and spa water circulation system, all system and pump controls must be in off 
position and filter manual air relief valve must be in open position.  Before starting pump, all system valves must be 
set in a position to allow system water to return back to the pool.  Do not change filter control valve position while 
pump is running.  Before starting pump, fully open filter manual air relief valve.  Do not close filter manual air relief 
valve until a steady stream of water (not air or air and water mix) is discharged from the valve.  All suction and 
discharge valves MUST be OPEN when starting the circulation system.  Failure to do so could result in severe 
personal injury and/or property damage. 

 

WARNING

 – Separation Hazard.

  Failure to follow safety and operation instructions could result in violent 

separation of pump components.  Strainer cover must be properly secured to pump housing with strainer cover lock 
ring.  Before servicing pool and spa circulation system, all system and pump controls must be in off position and 
filter manual air relief valve must be in open position.  Do not operate pool and spa circulation system if a system 
component is not assembled properly, damaged, or missing.  Do not operate pool and spa circulation system unless 
filter manual air relief valve body is in locked position in filter upper body.  All suction and discharge valves MUST be 
OPEN when starting the circulation system.  Failure to do so could result in severe personal injury and/or property 
damage. 

 

WARNING

 – Never operate the circulation system at more than 50 PSI maximum. 

WARNING

 

– Fire and burn hazard.

  Motors operate at high temperatures and if they are not properly isolated 

from any flammable structures or foreign debris they can cause fires, which may cause severe personal injury or 
death.  It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the 
risk for burns. 

 

WARNING

 – Failure to install according to defined instructions may result in severe personal injury or death.      

                

 WARNING

 – All electrical wiring MUST conform to local codes, regulations, and the National Electric Code. 

 

 

 

Содержание Spa Blower

Страница 1: ...ision St Elizabeth NJ 07207 Phone 908 355 7995 www hayward com Spa Blower Owner s Manual Spa Blower Note To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely SAVE THIS INSTRUCTION MANUAL ...

Страница 2: ... Rev A Table of Contents 1 IMPORTANT SAFETY INSTRUCTIONS 3 2 Wiring Instructions 6 3 Installation Guidelines 7 4 Blower Sizing for Air Channel 7 5 Blower Sizing Water Jets 8 6 New Spa Applications 9 7 Blower Replacement Existing Spa 9 8 Warranty 11 9 Product Registration 11 ...

Страница 3: ... NEC USE OF NON HAYWARD REPLACEMENT PARTS VOIDS WARRANTY ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS SPA BLOWER THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY WARNING To reduce risk of injury do not permit children to use or climb on this produ...

Страница 4: ...ARNING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a professional electrician on how to bond pump Also contact a licensed electrician for information on local electrical codes for bonding requirements Notes to electrician Use a solid copper conductor si...

Страница 5: ...ll system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while pump is running Before starting pump fully open filter manual air relief valve Do not close filter manual air relief valve until a steady stream of water not air or air and water mix is discharged from the valve All suction and discharge valves MUST be OPEN ...

Страница 6: ...er not air or air and water is discharged from valve Failure to do so could result in severe personal injury ATTENTION NEVER OPERATE THE PUMP WITHOUT WATER Water acts as a coolant and lubricant for the mechanical shaft seal NEVER run pump dry Running pump dry may damage seals causing leakage flooding and voids warranty Fill strainer housing with water before starting motor SAVE THESE INSTRUCTIONS ...

Страница 7: ...o the supply line by pre drilling a small hole through the neck of the blower and securing with a screw f A loop and check valve must be installed at least 1 foot above water level if the blower is installed below grade level g A loop and check valve must be installed a minimum of 1 foot above water level when supercharging water jets 4 Blower Sizing for Air Channel There are many variables to con...

Страница 8: ...s determine the size of your air blower For a 1 0 hp blower the total hole area should be 85 square inches for a 1 5 hp blower the hole area should be 1 2 square inches and for a 2 0 hp blower the total hole area should be 1 5 square inches The chart below shows some common hole sizes For example you could drill as many as 70 1 8 inch holes with a 1 0 hp blower Hole diameter in Hole area in square...

Страница 9: ... the installation guidelines for more details BLOWER SIZE VOLTS AMPS NUMBER OF WATER JETS 1 HP 120 240 6 7 3 5 4 TO 8 1 5 HP 120 240 8 0 4 0 8 TO 12 2 0 HP 120 240 10 0 6 0 14 OR MORE 7 Blower Replacement Existing Spa Determining the size of blower for an existing spa is more difficult since many factors including length of supply line and number of 90 degree turns are unknown under concrete and d...

Страница 10: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 10 of 12 Spa Blower ISSPB Rev A ...

Страница 11: ...nt No returns may be made directly to the factory without the express written authorization of Hayward pool Products To original purchasers of this equipment Hayward Pool Products warrants its products to be free from defects in materials and workmanship for a period of see below from the date of purchase Filters which become defective during the warranty period except as a result of freezing negl...

Страница 12: ...service 1 year 1 3 4 5 6 10 11 15 15 Purchased from_____________________________ Builder Retailer Pool Service Internet Catalog Company Name_________________________________ Address_______________________________________ City____________________ State_____ Zip__________ Phone_________________________________________ Type of Pool Concrete Gunite Vinyl Fiberglass Other_____________________________ N...