Spa Blower 

ISSPB   Rev-A 

 

 

WARNING

 – Pool and spa components (seals, gaskets, etc.) have a finite life.  All components should be 

inspected frequently and replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or 
not securely attached. 

 

WARNING

 – Risk of Electric Shock.  All electrical wiring MUST be in conformance with applicable local 

codes, regulations, and the National Electric Code (NEC).  Hazardous voltage can shock, burn, and cause death or 
serious property damage.  To reduce the risk of electric shock, do NOT use an extension cord to connect unit to 
electric supply.  Provide a properly located electrical receptacle.    Before working on blower or motor, turn off power 
supply to the blower. 

 

WARNING

 – To reduce the risk of electric shock replace damaged wiring immediately.  Locate conduit to 

prevent abuse from lawn mowers, hedge trimmers and other equipment. 

 

WARNING

 – Risk of Electric Shock.  In accordance with the National Electric Code (NEC), connect only to a 

branch circuit protected by a ground-fault circuit-interrupter (GFCI).  Contact a qualified electrician if you cannot 
verify that the circuit is protected by a GFCI.  The unit must be connected only to a supply circuit that is protected by 
a ground-fault circuit-interrupter (GFCI).  Such a GFCI should be provided by the installer and should be tested on a 
routine basis.  To test the GFCI, push the test circuit button.  The GFCI should interrupt power.  Push the reset button.  
Power should be restored.  If the GFCI fails to operate in this manner, the GFCI is defective.  If the GFCI interrupts 
power to the blower without the test button being pushed, a ground current is flowing, indicating the possibility of 
an electric shock.  Do not use this blower.  Disconnect the blower and have the problem corrected by a qualified 
service representative before using. 

 

WARNING

 – Failure to bond pump to pool structure will increase risk for electrocution and could result in 

injury or death.  To reduce the risk of electric shock, see installation instructions and consult a professional 
electrician on how to bond pump.  Also, contact a licensed electrician for information on local electrical codes for 
bonding requirements. 

Notes to electrician:

  Use a solid copper conductor, size 8 or larger.  Run a continuous wire from external bonding lug 

to reinforcing rod or mesh.  Connect a No. 8 AWG (8.4 mm

2

) [No. 6 AWG (13.3 mm

2

) for Canada] solid copper bonding 

wire to the pressure wire connector provided on the pump housing and to all metal parts of swimming pool, spa, or 
hot tub, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside 
walls of swimming pool, spa, or hot tub.  IMPORTANT - Reference NEC codes for all wiring standards including, but 
not limited to, grounding, bonding and other general wiring procedures. 

 

WARNING

 – Suction Entrapment Hazard.

  Suction in suction outlets and/or suction outlet covers, which are 

damaged, broken, cracked, missing, or unsecured cause severe injury and/or death due to the following entrapment 
hazards (symbols complements of APSP): 

Hair Entrapment

 - Hair can become entangled in suction outlet cover. 

Limb Entrapment

 - A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, 

broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb. 

Body Suction Entrapment

 - A differential pressure applied to a large portion of the body or limbs can result in an 

entrapment.  

Evisceration/ Disembowelment

 - A negative pressure applied directly to the intestines through an unprotected 

suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in 
evisceration/disembowelment. 

Mechanical Entrapment

 - There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be 

caught in an opening of a suction outlet cover resulting in mechanical entrapment. 

 

 

Содержание Spa Blower

Страница 1: ...ision St Elizabeth NJ 07207 Phone 908 355 7995 www hayward com Spa Blower Owner s Manual Spa Blower Note To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely SAVE THIS INSTRUCTION MANUAL ...

Страница 2: ... Rev A Table of Contents 1 IMPORTANT SAFETY INSTRUCTIONS 3 2 Wiring Instructions 6 3 Installation Guidelines 7 4 Blower Sizing for Air Channel 7 5 Blower Sizing Water Jets 8 6 New Spa Applications 9 7 Blower Replacement Existing Spa 9 8 Warranty 11 9 Product Registration 11 ...

Страница 3: ... NEC USE OF NON HAYWARD REPLACEMENT PARTS VOIDS WARRANTY ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS SPA BLOWER THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY WARNING To reduce risk of injury do not permit children to use or climb on this produ...

Страница 4: ...ARNING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a professional electrician on how to bond pump Also contact a licensed electrician for information on local electrical codes for bonding requirements Notes to electrician Use a solid copper conductor si...

Страница 5: ...ll system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while pump is running Before starting pump fully open filter manual air relief valve Do not close filter manual air relief valve until a steady stream of water not air or air and water mix is discharged from the valve All suction and discharge valves MUST be OPEN ...

Страница 6: ...er not air or air and water is discharged from valve Failure to do so could result in severe personal injury ATTENTION NEVER OPERATE THE PUMP WITHOUT WATER Water acts as a coolant and lubricant for the mechanical shaft seal NEVER run pump dry Running pump dry may damage seals causing leakage flooding and voids warranty Fill strainer housing with water before starting motor SAVE THESE INSTRUCTIONS ...

Страница 7: ...o the supply line by pre drilling a small hole through the neck of the blower and securing with a screw f A loop and check valve must be installed at least 1 foot above water level if the blower is installed below grade level g A loop and check valve must be installed a minimum of 1 foot above water level when supercharging water jets 4 Blower Sizing for Air Channel There are many variables to con...

Страница 8: ...s determine the size of your air blower For a 1 0 hp blower the total hole area should be 85 square inches for a 1 5 hp blower the hole area should be 1 2 square inches and for a 2 0 hp blower the total hole area should be 1 5 square inches The chart below shows some common hole sizes For example you could drill as many as 70 1 8 inch holes with a 1 0 hp blower Hole diameter in Hole area in square...

Страница 9: ... the installation guidelines for more details BLOWER SIZE VOLTS AMPS NUMBER OF WATER JETS 1 HP 120 240 6 7 3 5 4 TO 8 1 5 HP 120 240 8 0 4 0 8 TO 12 2 0 HP 120 240 10 0 6 0 14 OR MORE 7 Blower Replacement Existing Spa Determining the size of blower for an existing spa is more difficult since many factors including length of supply line and number of 90 degree turns are unknown under concrete and d...

Страница 10: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 10 of 12 Spa Blower ISSPB Rev A ...

Страница 11: ...nt No returns may be made directly to the factory without the express written authorization of Hayward pool Products To original purchasers of this equipment Hayward Pool Products warrants its products to be free from defects in materials and workmanship for a period of see below from the date of purchase Filters which become defective during the warranty period except as a result of freezing negl...

Страница 12: ...service 1 year 1 3 4 5 6 10 11 15 15 Purchased from_____________________________ Builder Retailer Pool Service Internet Catalog Company Name_________________________________ Address_______________________________________ City____________________ State_____ Zip__________ Phone_________________________________________ Type of Pool Concrete Gunite Vinyl Fiberglass Other_____________________________ N...

Отзывы: