5
Position the Vessel in a manner where the Cell can be easily inserted and removed.
Secure the Vessel to the cut pipe by tightening the Nuts as shown below. Handtighten
the Nuts to stop, then continue 1/4 turn more using the included strap wrench. If
the Inspection marks can be seen, the pipe has not been inserted far enough into
the Cell Vessel.
Remove the foam protector from the Cell. Verify that the O-Ring is attached before
inserting the Cell into the Cell Vessel.
IMPORTANT:
Inspection
Marks should
not be visible
Verify that both Cell
Vessel gaskets are in place
Insert Cell
Vessel and
hand tighten
Nuts
6
7
Use the included strap wrench
to tighten an additional 1/4 turn
If so, loosen
Nuts and slide
the pipes further
into the Cell
Vessel and
re-tighten
O-Ring