1.3.1.4.2. Solvent-Weld End Connectors (PVC and CPVC only): 

 

 
 
 
 
 

 

1.3.1.4.2.1.  Refer to solvent-cement manufacturer’s instructions and cure times. 
1.3.1.4.2.2. 

Do not install strainer body until solvent cement has fully cured.  

Reinstall end connectors by threading nuts 

onto body by rotating in a clockwise direction. 
 

1.3.1.4.3. Flange Connections: 

1.3.1.4.3.1.  NOTE:  When  provided  with  flanges,  PVC,  CPVC,  or  GFPP  SB  Series  Strainers  are  provided  with  an  end 

connection  sub-assembly,  consisting  of  an  end  connector,  connected  to  a  flange,  with  an  assembly  nut  for 
connection to the strainer body. 

1.3.1.4.3.2.  Flange bolts should be tight enough to compress the gasket and make a good seal, without distorting or putting 

excessive stress on the flanges. Suitable washers should be used between the bolt head and flange and the nut 
and flange. Bolts should be tightened in alternating sequence (Figure 1).  See Table 1 for recommended torque. 

 

                                                                  

 

 
 

                

          

                          

                  

 

                             
 
 
                        Fig. 5: Bolt Tightening Sequence                                         Table 1.  Recommended Flange Bolt Torque 
 

 

1.3.1.5   Once end connectors are installed in piping system, thread the true union nuts onto the inlet and outlet of the strainer body. 

 
 

2. 

OPERATION 

 

2.1 

 

Installing the Basket: 

 

2.1.1 

To install the basket into the SB Series Basket Strainer, place basket inside vessel aligning shoulder of basket with shoulder of 
vessel body. 

2.2 

     

Filling and Pressurizing the Basket Strainer 

2.2.1 

To fill and pressurize Hayward SB-Series Basket Strainer: 

2.2.1.1 

Verify that cover o-ring, cover o-ring groove, and cover sealing surface are clean. 

2.2.1.2 

Verify that cover o-ring is seated inside o-ring groove. 

2.2.1.3 

Open  vent  vi a   t h e   t h u m b s c re w  on  top  of  cover (vent  is  opened  by  rotating  t he  t hum bscrew  counter-
clockwise).  NOTE:  Process  media  will  be allowed  to  escape through  outlet  of  vent  as  vessel  is  filled.  Prepare to 
capture, collect, and dispose of vented chemicals properly. 

2.2.1.4 

Install cover firmly onto vessel body 

2.2.1.5 

Do not strike cover. 

2.2.1.6 

Do not attempt to over-tighten cover. 

2.2.1.7 

Cover is sealed by means of a pressure energized face sealing o-ring.  

Tighten cover hand-tight plus 

approximately 1/8-turn 

(i.e. 45º).  It is not necessary to tighten cover beyond hand tight plus 1/8-turn.

 

2.2.1.8 

Slowly open valve upstream of vessel and start system pump (if necessary). 

2.2.1.9 

Allow process media to fill vessel, air will be purged through vent on top of cover.  After all air has been purged, 
process media will start flowing through vent .  Close vent by rotating the thumbscrew clockwise. 

2.2.1.10  Allow pressure to slowly increase until system operating pressure is reached. 

 
 

Flange Size 

Bolt Dia. (in.) 

Torque (ft. lbs.) 

½”

 

1/2 

10 – 15 

¾”

 

1/2 

10 – 15 

1” 

1/2 

10 – 15 

1-¼” 

1/2 

10 – 15 

1-½” 

1/2 

10 – 15 

2” 

5/8 

15 – 20 

2-1/2” 

5/8 

20 – 25 

3” 

5/8 

20 – 25 

4” 

5/8 

20 – 25 

CAUTION 

Strainer body must be disassembled from nuts and end connectors prior to solvent cementing end connections into system,  Avoid exposing 

strainer body and end connector o-rings to primer, solvent cement, or their fumes, as damage to the strainer could result. 

 

Содержание PVC Series

Страница 1: ...rature on plastic piping systems must be considered when the systems are initially designed The pressure rating of plastic systems must be reduced with increasing temperature Maximum operating pressur...

Страница 2: ...ward recommends using 3 8 diameter bolts or studs with flat washers and lock washers for mounting the vessel The bolts or studs should be torqued to 5 ft lb in an alternating sequence in order to secu...

Страница 3: ...ction 1 3 1 3 Remove the nuts and end connectors from strainer body by rotating the nuts counter clockwise Verify end connector o rings are installed in their respective grooves 1 3 1 4 Place nut over...

Страница 4: ...ssurizing the Basket Strainer 2 2 1 To fill and pressurize Hayward SB Series Basket Strainer 2 2 1 1 Verify that cover o ring cover o ring groove and cover sealing surface are clean 2 2 1 2 Verify tha...

Страница 5: ...age personal injury or even death 2 4 1 To depressurize and drain Hayward SB Series Basket Strainer 2 4 1 1 Slowly close valves upstream and downstream of basket strainer any Hayward product WARNING O...

Страница 6: ...nd inspect o ring grooves and o rings each time the cover or end connector is removed Damaged o rings should be replaced immediately 4 TROUBLESHOOTING Problem Cause Solution Leak between cover and bod...

Страница 7: ...1 5 m s for Simplex Basket Strainer Chart 1 Operating Pressures of PVC CPVC and GFPP Materials at Elevated Temperatures NOTES KrytoxTM is a trademark of The Chemours Company A full manual is availabl...

Страница 8: ...t or parts thereof found to be defective HAYWARD MAKES NO OTHER REPRESENTATION OR WARRANTY EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PART...

Отзывы: