10
4. USAGE AND OPERATION
• When running, press “
” to check the current status of the unit. You can check
water-inlet/water-outlet/condenser/ambient temperature. If no buttons are pressed
within 5 seconds, the LED will display water-inlet/water-outlet temperature.
When the unit is switched off, current ambient temperature is displayed.
The unit's operation data can be set on the control panel.
Please set according the below table:
Remarks:
*Parameter 0: cooling mode only.
**Parameter 09:
0: always open.
1: 60 second delay before compressors start.
30 second delay after compressors stop.
Digit
Meaning
Range
Default
Adjust (yes/no)
*0
Return water temperature setting
(cooling mode)
8-28°C
27°C
yes
1
Return water temperature setting
(heating mode)
15-40°C
27°C
yes
2
Total working time of compressor after
defrost cycle
30-90 MIN
45 MIN
yes
3
Set defrost cycle start-up temperature
0-30°C
-6°C
yes
4
Set defrost cycle stop temperature
0-30°C
13°C
yes
5
Max. duration of defrost cycle
1-12 MIN
8 MIN
yes
6
System quantity
1-2
2
yes
7
Automatic restarting
0-1
0 (no) 1 (yes)
1
yes
8
Model (cooling only/heat
pump/auxiliary electrical heating/hot
water)
0/1/2/3
3
yes
**9
Water pump model
0/1
1
yes
Содержание POWERLINE 15-81500
Страница 19: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ...
Страница 37: ...UNIDAD DE BOMBA DE CALOR PARA PISCINAS Manual de Instalación e Instrucciones ...
Страница 55: ...BOMBA DE AQUECIMENTO PARA PISCINAS Manual de instalação e de instruções ...
Страница 73: ...HEIZPUMPENANLAGE FÜR EIN SCHWIMMBECKEN Einbau Anleitungshandbuch ...
Страница 91: ...ZWEMBAD WARMTEPOMP Installatie en bedieningshandleiding ...
Страница 109: ...UNITÀ DI RISCALDAMENTO A POMPA DI CALORE PER PISCINE Manuale d Uso e di Installazione ...
Страница 127: ...VARMEPUMPE TIL SVØMMEBASSENG Installerings og brukerveiledning ...
Страница 145: ...ТЕПЛОВОЙ НАСОС ДЛЯ ПЛАВАТЕЛЬНОГО БАССЕЙНА Руководство по монтажу и эксплуатации ...