9
Use Only Genuine Hayward Replacement Parts.
W
Waarrn
niin
ng
g -- R
Riisskk ooff IIn
njju
urryy
The Filtration and Booster Pumps must be
O
OF
FF
F
when connecting
or disconnecting cleaner hose.
C
Caau
uttiioon
n -- R
Riisskk ooff E
Eq
qu
uiip
pm
meen
ntt D
Daam
maag
gee
The filter pump must always be run to clear air from the system
before turning the Booster Pump
O
ON
N.. N
Ne
evve
err rru
un
n
the Booster
Pump without the main filter pump
O
ON
N
. Running the Booster
Pump dry will damage the Booster Pump and void the warranty.
O
Op
peerraattiin
ng
g tth
hee P
Ph
haan
nttoom
m T
Tu
urrb
boo C
Clleeaan
neerr
1
1..
Be sure all filtration system valves are open and supplying
water to the Booster Pump.
2
2..
Be sure valves to and from the Booster Pump and dedicated
return line are fully opened.
3
3..
The Phantom Turbo Cleaner and its Booster Pump can only
operate when the pool’s filter pump is operating.
C
Caau
uttiioon
n -- R
Riisskk ooff E
Eq
qu
uiip
pm
meen
ntt D
Daam
maag
gee
Failure to open valves fully and/or failure to have the filtration
system operating will damage the Booster Pump. This damage
voids the Booster Pump’s warranty.
S
Seettttiin
ng
g P
Prreessssu
urree
IIm
mp
po
orrtta
an
ntt::
The cleaner will not operate properly if the pressure
is not properly set. Too little pressure will prevent proper
movement and cleaning. Too much pressure will cause poor
cleaning and premature wear of Cleaner parts.
W
Waarrn
niin
ng
g -- R
Riisskk ooff IIn
njju
urryy
Be careful to hold the Cleaner Connector (Part C) with the Setup
Pressure Gauge (Part U) attached under water and not to be
sprayed by the hole in the Setup Pressure Gauge or by the
Sweep Hose.
N
Ne
evve
err
point a jet or hose at people or pets.
Clip the Setup Pressure Gauge to the hose near the Wall Quick
Connect.
1
1..
Turn the filtration system pump
O
ON
N
then the Booster Pump
O
ON
N
. Read the pressure on the Setup Pressure Gauge
connected to the Cleaner Connector. Use a flat blade
screwdriver to adjust the Wall Quick Connect Knob
(see figure 2) until the pressure reads 25 PSI (
+
/- 5 PSI).
N
No
otte
e::
The Wall Quick Connect can be adjusted from “0”
(fully closed) to “5” (fully open). Do
N
NO
OT
T
force the
adjustment knob beyond “0” or “5”.
2
2..
If the Wall Connector is on Position “5” (fully open) and the
pressure is still below 20 PSI, check for clogged Filter, Pump
Strainer Basket, Main Drain, Skimmer Basket, etc., to
determine why there is insufficient water pressure at the
dedicated line. If more pressure is still required have an
Authorized Hayward Pool Dealer or Service person check
the Booster Pump, Filtration System and Plumbing to
determine if they are functioning correctly.
3
3..
Turn the Booster Pump and Filtration Pump
O
OF
FF
F
.
4
4..
R
Re
em
mo
ovve
e tth
he
e S
Se
ettu
up
p P
Prre
essssu
urre
e G
Ga
au
ug
ge
e
from the Cleaner
Connector. Store the Setup Pressure Gauge with the
Owner’s Guide in a safe place.
5
5..
Attach the Cleaner Connector to Cleaner. The Sweep Hose
should be directly below the Pressure Hose.
6
6..
Place the cleaner in the pool, turn the Filtration system
O
ON
N
,
then turn the Booster Pump
O
ON
N
.
C
Co
on
nn
ne
eccttiin
ng
g P
Prre
essssu
urre
e H
Ho
osse
e tto
o C
Clle
ea
an
ne
err
A
Ad
djju
ussttiin
ng
g P
Prre
essssu
urre
e a
att W
Wa
allll C
Co
on
nn
ne
ecctto
orr
S
Se
ettu
up
p P
Prre
essssu
urre
e G
Ga
au
ug
ge
e &
& W
Wa
allll C
Co
on
nn
ne
ecctt
K
C
U
C
7
7..
Lubricate the swivel on the 3 ft. Hose Wall End Assembly (Part T)
in soapy water then snap into one of the Pipe Assemblies.
8
8..
Lubricate the swivel on the Hose Cleaner End Assembly (Part S)
in soapy water then snap into a different Pipe Assembly.
9
9..
Open Bag #2 and lubricate both ends of the Hose Swivel
Assemblies (Part R) in soapy water. Connect the Pipe
Assemblies by snapping the Hose Swivel Assemblies into each
of the Pipe Assemblies.
C
Coon
nn
neeccttiin
ng
g H
Hoossee ttoo W
Waallll FFiittttiin
ng
g
1
1..
With the Booster Pump and Filtration system turned
O
OF
FF
F
,
look down from the pool deck and hold the Wall Quick
Connect so the hose is to the left and the adjustment knob
is to the right. Insert the Wall Quick Connect into the
Universal Wall Fitting and turn it to the left (counter
clockwise) to lock. The hose should be on the bottom below
the adjustment knob.
2
2..
Pull the Wall Quick Connect outward to check that the Wall
Quick Connect is locked into the Universal Wall Fitting.
3
3..
To
d
diisscco
on
nn
ne
ecctt
the hose, first turn the Booster Pump and
Filtration pump
O
OF
FF
F
then push the Wall Quick Connect
toward the wall, turn it to the right (clockwise) and pull the
Wall Quick Connect out of the Universal Wall Fitting.
D
Diissccoon
nn
neeccttiin
ng
g aa H
Hoossee P
Piip
pee
If it is necessary to shorten, lengthen or replace a component
of the Rigid Pressure Hose, the Snap Fits can be undone with
two small screwdrivers.
8
Use Only Genuine Hayward Replacement Parts.
W
Wa
allll Q
Qu
uiicck
k C
Co
on
nn
ne
ecctt
C
Coon
nn
neeccttiin
ng
g T
Th
hee R
Riig
giid
d P
Prreessssu
urree H
Hoossee ttoo P
Pooooll
O
Op
peerraattiin
ng
g tth
hee P
Ph
haan
nttoom
m T
Tu
urrb
boo C
Clleeaan
neerr
W
Wa
allll C
Co
on
nn
ne
ecctto
orr A
Asssse
em
mb
bllyy
H
Ho
osse
e C
Clle
ea
an
ne
err E
En
nd
d A
Asssse
em
mb
bllyy
T
Q
N
H
Ho
osse
e S
Sw
wiivve
ell A
Asssse
em
mb
bllyy
R
N
R
Riig
giid
d P
Prre
essssu
urre
e H
Ho
osse
e A
Asssse
em
mb
bllyy
S
Figure 1
Figure 2
Figure 3
IItt iiss e
esssse
en
nttiia
all tth
ha
att tth
he
e H
Ho
osse
e S
Sw
wiivve
ell A
Asssse
em
mb
blliie
ess a
arre
e
iin
nsstta
alllle
ed
d cco
orrrre
eccttllyy tto
o e
en
nssu
urre
e tta
an
ng
glle
e ffrre
ee
e o
op
pe
erra
attiio
on
n o
off tth
he
e
P
Ph
ha
an
ntto
om
m T
Tu
urrb
bo
o..