Page 14 of 22
HEATPRO HEAT PUMP
HP13023772 Rev: D
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908.351.5400 www.haywardpool.com
Owner Inspection
Hayward recommends that you inspect your heat pump on a seasonal basis and especially after significant
weather events. Refer to the sections of this Manual: “Clearance”, “Roof Run-Off”, “Drainage and
Condensation” for proper inspection.
Professional Inspection
WARNING - RISK OF ELECTRIC SHOCK OR ELECTROCUTION.
Before servicing heat pump or
motor, disconnect ALL electrical power. An EPA Certified service technician MUST perform inspection.
Note:
Hayward recommends annual equipment inspections.
Note:
Never use high-pressure water to clean evaporator coil fins, as this will cause damage to the coil.
Summertime Shutdown
For certain areas during the summer months, when the heat pump is not needed, you can place the heat pump in
standby mode.
End of Season (Winterizing)
Failure to properly winterize heat pump may result in serious equipment damage.
Freeze damage is NOT
covered under the heat pump warranty.
Many pool service companies offer “Winterizing” assistance. Hayward recommends using a professional
service technician for these procedures
.
•
All cleaning of the heat pump. Incorrect cleaning of the unit can cause damage to the heat pump and
diminish the operating life.
•
Disconnect the power supply (usually at the circuit breaker in your house) prior to winterizing your heat
pump.
Cover the heat pump to protect it from snow and water, which may freeze and damage the unit.
BE
ABSOLUTELY CERTAIN TO DISCONNECT THE HEAT PUMP FROM THE UNIONS AND DRAIN
ALL WATER LINES.