Hayward H250IDL2 Скачать руководство пользователя страница 22

ed to repair or replacement of the defective heater or

part, as provided herein and the Company is not

responsible hereunder for incidental or consequential

or incidental costs or damages. The company neither

assumes, nor authorizes any person or firm to

assume for us, any further liability or obligation in

connection with the sale, installation, use, mainte-

nance, or existence of the heater.

SAFETY WARNING:

Pool heaters are heat producing

appliances and to avoid damage or injury in the event

of possible overheating of the outer jacket (1) no

materials should be stored against the jacket and (2)

care should be taken to avoid unnecessary contact

(especially by children) with the jacket. When lighting

a gas heater, the lighting instructions must be fol-

lowed exactly to prevent “flashback” of excess gas in

the heater. Electronic ignition heaters and electric

heaters must have the power shut off when making

adjustments to, servicing, or coming into contact with

the heater. UNDER NO CIRCUMSTANCES SHOULD

FLAMMABLE MATERIALS, SUCH AS GASOLINE 

OR PAINT THINNERS, BE USED OR STORED IN

THE VICINITY OF THE HEATER OR IN ANY LOCA-

TION FROM WHICH FUMES COULD REACH THE

HEATER. For your comfort, enjoyment and safety,

please read the enclosed operating instructions care-

fully.

FireTile™ five year limited warranty: 

TERMS AND COVERAGE:

This warranty is an

extended warranty applicable to the FireTile™ com-

ponents used in the conditions, limitations, and

exceptions of the regular pool heater limited warranty

remain in force, apply to this warranty, and are incor-

porated herein by reference.
Under the terms of this special FireTile™ limited war-

ranty, we will replace (cost of freight, installation, cost

of fuel, and service labor at user’s expense) any com-

ponents of your pool/spa heater made of FireTile™

which fail from defects in workmanship and materials

under normal use and service in a single family rei-

dential application for a period of five (5) years.

43

Hayward Pool Heater Certificate of Limited Warranty

Limited heater warranty:

TERMS AND COVERAGE:

We warrant our pool

heater to be free from defects in workmanship and

materials under normal use and service. Pursuant to

this warranty and subject to the Conditions and

Exceptions indicated below:

1. We will replace (cost of freight, installation, cost of 

fuel, and service labor at user’s expense) with the 

prevailing comparable model, or, at our option, 

repair any pool/spa heater that leaks under normal 

use and service within one year from the date of 

original installation for all users.

2. In addition, we will replace (cost of freight, insta-

llation, cost of fuel, and service labor at user’s 

expense) or, at our option, repair any part or parts

of the pool/spa heater which malfunctions under 

normal use and service within one year from the 

date of original installation for all users.

LIMITATION ON IMPLIED WARRANTIES:

WE ARE

NOT LIABLE FOR ANY CONSEQUENTIAL DAM-

AGES FOR BREACH OF ANY WRITTEN OR

IMPLIED WARRANTY OF THIS PRODUCT. Implied

warranties, including the WARRANTY of MER-

CHANTABILITY and all other implied warranties that

may arise from course of dealing or usage of trade

imposed on the sale of this heater under laws of the

state are limited in duration to the term of one (1)

year for all users. There are no warranties which

extend beyond the description on the face hereof. We

shall not in any event be held liable for any special,

indirect, or consequential damages.

EXPENSE OF DELIVERY AND INSTALLATION:

Each pool heater or replacement part to be furnished

under this warranty shall be furnished at our nearest

distribution center. We shall not pay, nor be responsi-

ble for shipping or delivery charges to the place of

installation, nor for labor charges or other costs of

removal or installation. Every defective heater or part

replaced under this warranty shall become our prop-

erty, and as such, must be returned to our distribution

center with transportation charges paid by the user.

Any replacement pool heater furnished under this

warranty shall remain in warranty only for the unex-

pired portion of this warranty.

CONDITIONS AND EXCEPTIONS:

This warranty

applies only to the pool/spa at its original place of

installation and only for the original owner. It does not

apply if the pool heater is installed in violation of any

applicable code or ordinance, or is not installed, oper-

ated and maintained in accordance with our instruc-

tions, or is misused, damaged by accident, weather,

act of God, freezing, water void and/or excess pres-

sure, altered or disconnected. It does not apply with

respect to:

1. A heater not equipped with Certified C.S.A. limit 

controls or equivalent pressure relief valve.

2. A heater operated with settings in excess of, 

and/or with fuel not conforming to those shown 

on rating plate;

3. A heater on which the serial numbers have been 

altered, defaced, or removed.

4. Leaks arising from defective installation;

5. Production of noise, odors, or discolored (rusty, 

etc.) water;

6. Leakage substantially contributed to by sediment,

lime precipitate and/or higher than normal 

dissolved solids (pH above 7.8) in the tank, 

copper tubes, or water ways;

7. Leakage caused substantially contributed to by 

corrosive elements in the atmosphere (such as 

the storage of chlorine or other chemicals);

8. Leakage caused substantially or contributed to by

corrosive pool water in an acid condition (pH 

below 7.2);

9. Damage caused substantially or contributed to by

an external source of energy;

10. A pool/spa heater is a water containing device. 

Leakage of water from this device can be expected

at some time due to malfunction or the limitations 

of the service life of various components. 

Do not install this product where such leakage 

can cause damage. MANUFACTURER IS NOT

RESPONSIBLE OR LIABLE FOR ANY COSTS 

INCURRED BY SUCH DAMAGE.

IN NO CASE ARE WE TO HELD LIABLE FOR DAM-

AGE TO SURROUNDING AREA OR PROPERTY

CAUSED BY LEAKAGE OR MALFUNCTION.

HOW TO CLAIM UNDER THIS WARRANTY:

The

original owner, upon discovering the defect, must

present the attached completed warranty claim card

with proof of purchase either to the dealer or notify

the Company in writing at either address:

Hayward Pool Products, Inc.

900 Fairmont Avenue

Elizabeth, NJ 07207

or

Hayward Pool Products, Inc.

2875 Pomona Boulevard

Pomona, CA 91768

Upon receipt of such notification we shall decide

whether to repair such parts or replace any pool

heater, reserving at all times the right to inspect in

order to verify any claimed defect. We also reserve

the right to have our representatives make any

inspections, repairs, or to furnish replacements. This

warranty is intended as a legally binding obligation of

the Company, enforceable in the courts. This warran-

ty may give you specific legal rights which may vary

from state to state.

LIMITATION ON LIABILITY

: All intended representa-

tions have been expressly set forth in this document.

This warranty may not be extended by oral or any

other additional representations, written sales infor-

mation, drawings, or other malfunction, is strictly limit-

42

LIMITED 1 YEAR POOL/SPA/HOT TUB HEATER CLAIM FORM

Model No. _______________________________  Serial No. ______________________________________

Purchaser’s Name _______________________________________________________________________

Installation Address _______________________________________________________________________

City/State/Zip ___________________________________________________________________________

Single Family Residential Use    

c

Yes   

c

No    If no, fill in use _____________________________________

Dealer’s Name __________________________________________________________________________

Address ________________________________________________________________________________

Date of Installation _______________________________________________________________________

Note to Dealer: Fill in the following information on replacement heater.

Model No. _______________________  Serial No. __________________  Date Installed ________________

USE THIS FORM ONLY FOR MAKING A CLAIM

Cut on line

Содержание H250IDL2

Страница 1: ...and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causi...

Страница 2: ...ement see warranty certificate included in this manual CAUTION If the pool spa heater is damaged or destroyed by improper maintenance excessive water hardness incorrect water chemistry or freezing it...

Страница 3: ...screws from left and right side access panels Remove panels 4 Remove the front panel 5 Disconnect high limit wires and reroute them to opposite side of heater Disconnect the thermistor leads from cont...

Страница 4: ...test edition of the National Fuel Gas Code ANSI Z223 1 7 12 Lift out heat exchanger and rotate it 180 degrees horizontally DO NOT FLIP IT OVER This End Up sticker should be pointing up 13 Reinstall fr...

Страница 5: ...upon the model of heater See section titled Indoor Installation and Venting for indoor installation and venting guidelines 8 Vent Collar Diameters Model Diameter H250IDL H350IDL H400IDL 6 inches 8 inc...

Страница 6: ...23 1 or the CAN CGA B149 Installation Codes Local Codes and the Vent Manufacturer s Instructions See Figure 17 for permissible vent diameters for these heaters See Figure 18 for maximum permissible ve...

Страница 7: ...ve the capacity to supply enough gas to the pool heater and any other gas appliances if they are on the same pipeline Example 225 meter 225 000 BTUH If doubt exists as to the meter size consult local...

Страница 8: ...heater usage for very large pools with and without an external by pass balancing valve NOTE Improperly adjusted by pass valves may result in damage to the heater this damage is not covered under warr...

Страница 9: ...is installed more than three 3 feet above the surface of pool spa water install a loop as shown on Figure 32 to prevent drainage of water in heater during filter change For installation below pool sp...

Страница 10: ...internal thermostat to regulate the water temperature to the set point of the mode selected Bypass Operation Note the following information when setting up the IDL2 for Bypass Operation control via a...

Страница 11: ...tem is filled with water and purged of all air prior to starting heater Gas line testing The appliance and its gas connection must be leak tested before placing the appliance in operation The heater a...

Страница 12: ...directly into the skimmer High chemical concentra tions may result when the pump is not running High chemical concentrations will cause very rapid corro sion of the heat exchanger Such damage is not c...

Страница 13: ...ress the MODE key to put the heater in the POOL or SPA mode The POOL LED will illuminate to indicate that the control is in the POOL mode and the water temperature is to be controlled to the pool setp...

Страница 14: ...1 The control de energizes the gas valve after the 4 second ignition trial ends 2 The control operates the blower during a 30 second post purge period 3 The control monitors for open contacts at the b...

Страница 15: ...ners are not blocked the valves in the piping are properly positioned and the time clocks are prop erly set WARNING Do not attempt to repair any compo nents of heater Do not modify heater in any manne...

Страница 16: ...To remove fuse board 1 Disconnect all wires from fuse board 2 Detach from sheetmetal panel Reverse the above procedures for installation Vent Pressure switch The vent pressure switch will not allow th...

Страница 17: ...urn water temperature To replace thermistor 1 Turn pump gas supply and heater power off 2 Drain heat exchanger of all water 3 Remove side access panels 4 Disconnect thermistor leads from circuit board...

Страница 18: ...erse the above procedures Combustion blower The combustion blower provides the air that mixes with the gas from the main burners for the combus tion process On initial start up the blower operates for...

Страница 19: ...ard This cable is not polarized and can be inserted upside down if it was removed when electrical was done Invert the cable on the connector pin and see if the display is now on The display may read C...

Страница 20: ...IDL Heater Diagnostic Guide IDL Heater Diagnostic Guide Code Fault Diagnosis Step Remedy 1 Check for faulty wiring or connection Inspect vent pressure switch wiring Ensure wire harness terminals are...

Страница 21: ...NER ORIFICE PROPANE H3501DPL2 14 HAXMAN1250 GAS MANIFOLD H250 14 HAXMAN1400 GAS MANIFOLD H350 400 15 IDXL2ICB1931 IGNITION BOARD ONLY 16A IDXL2PBA1250 PANEL BEZEL KEYPAD ASY H250IDL2 16A IDXL2PBA1400...

Страница 22: ...ortation charges paid by the user Any replacement pool heater furnished under this warranty shall remain in warranty only for the unex pired portion of this warranty CONDITIONS AND EXCEPTIONS This war...

Страница 23: ...l Products Inc 2875 Pomona Boulevard Pomona CA 91768 Hayward Pool Products Inc 2880 Plymouth Drive Oakville Ontario L6H 5R4 Hayward S A Zoming de Jumet B6040 Jumet Belgium 2004 Hayward Printed in U S...