USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 8 of 16
AquaRite
®
Pro LS
Rev. D
If the current (amps) display is 0.00 A, then the chlorinator is operating normally but is in the off part of
its normal operating cycle. Simply press either the “+” or “-“ key to start a new cycle
The AquaRite Pro LS periodically reverses the polarity of the voltage applied to the cell in order to
automatically clean off any calcium deposits that may have built up on the cell. It is important that you
check the chlorinator operation in both polarities. To do this, press either the “+” or “-“ buttons and the
chlorinator will turn off, wait for 15 seconds and then turn on in the opposite polarity.
Salt Level
1.5 g/L
No Function
Move to previous/next menu item
This is the average "Salt Level" in the pool. This value is calculated over time and minimizes the effects
of spikes or dips that may naturally occur.
Press to load the "Instant Salt" into the averaged salt display
Move to previous/next menu item
Instant Salt
1.5 g/L (+=save)
The “Instant Salt” is calculated based on the voltage, current (amps), and water temperature at the cell
at that instant. There are a number of reasons why instant and average salt readings may differ. Some
of these include salt having just been added to the pool and not yet thoroughly mixed, calcium buildup
on the cell, and cell aging.
Press the "+" button to enter the instant salt value into the average salt level. The average salt level will
use this new value for its calculations.
Flow Switch
Flow
No Function
Move to previous/next menu item
The current status of the flow switch is displayed. There is a short delay when transitioning from flow to
no-flow and a longer delay on the transition from no-flow to flow. The delay time is displayed.
Main Software
Revision 1.00
No Function
Move to previous/next menu item
Display Software
Revision 1.00
No Function
Move to previous/next menu item
Chemistry Sense
Software r1.00
No Function
Move to previous/next menu item
Available displays depend on configuration. These displays show the software revisions of various
components.
Press to reset
Move to previous/next menu item
Inspect Cell
hold + to reset
For optimum operation, you will need to inspect the AquaRite Pro LS chlorinator cell approximately every
3 months and clean the cell if necessary. The AquaRite Pro LS will automatically remind you and display
“Inspect Cell, hold + to reset” as part of the rotating Information Menu. Clean the cell and then press the
“+” button during the “Inspect Cell” display to reset the timer.
Function depends on displayed menu item
Move to next Check System condition or previous/next menu item
Check System
Low Salt
Refer to the Troubleshooting section for information about error conditions and possible causes.