![Hayward AquaRite UV LS Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/hayward/aquarite-uv-ls/aquarite-uv-ls_owners-manual_2111054014.webp)
14
5.1
FILTRATION / Automatic mode
5.3
FILTRATION / Heating mode
5.2
FILTRATION / Smart mode
5.4
FILTRATION / Intelligent mode
5.5
FILTRATION / Filter cleaning
5.5
Timed heating with option of climatization*:
This mode acts equally to the automatic mode, but besides it includes the option to work on a
relay to control the temperature. The desired temperature is set in this menu, and the system works with a hysteresis of 1 degree (example: the
setting temperature is 23° C, the system will activate itself when the temperature goes below 22° C and will not stop before it passes 23° C).
Use the
plus/minus
keys to set the desired temperatures and
ON/OFF
of the Heating.
Clima OFF:
The heating only works within the set filtration periods.
Clima ON:
Keeps the filtration working when the filtration period is finished if the water temperature is below the setting temperature. When the
setting temperature is reached the filtration and the heating will stop and will not switch on till the next programmed filtration period.
To set the
ON/OFF
times (up to 3 possible time programmable), follow the instructions of the
Automatic Mode.
See section
Filter Cleaning
below.
5.5
5.7
5.6
Intelligent*:
In this mode the user has 2 working parameters to guaranty the desired water temperature with a minimum of filtration hours:
You select the desired water temperature and the minimum filtration time (minimum of 2 hours and maximum of 24 hours). The device divides
the selected “minimum filtration time” in 12 fragments which start up every 2 hours. If one of these fragments finishes, without the temperature
reaching the desired level, the filtration/heating continues until the desired temperature is accomplished. In order to keep the filtration-electricity-
cost to a minimum, this additional filtration time is subtracted from the following fragments of the “minimum filtration time”. The first 10 minutes
of each fragment will not be subtracted.
Example (see diagram): Minimum temperature = 28°C and minimum filtration time = 12 hours.
The desired water temperature and the minimum filtration time is set with the
plus/minus
keys .
See section
Filter Cleaning
below.
5.6
0h
10 min
1h
OFF
ON
3h
5h
7h
9h
11h
13h
15h
17h
19h
21h
23h
2h
4h
6h
8h
10h
12h
14h
16h
18h
20h
22h
24h
27ºC
27ºC
28ºC
28ºC
28ºC
DIAGRAM INTELLIGENT MODE
* Note:
Mode only visible if the option to use temperature probe and/or
heating
is activated in the “Installer Menu”.
* Note:
Mode only visible if the option to use temperature probe and/or
heating
is activated in the “Installer Menu”.
* Note:
Mode only visible if the option to use temperature probe and/or
heating
is activated in the “Installer Menu”.
5.7
Filter cleaning mode (and pool cleanig by sucction):
From this menu (accessible from any Filtration mode) It can be easily performed
a backwashing cleaning of the sand filter. Activating this menu from any filtration mode (Manual, Automatic, Heating, Smart, Intelligent), will
disconnect electrolysis/hydrolysis cell. Then proceed as follows:
• Put the filter pump
OFF
with
plus/minus
keys
.
• Place the filtration pump valve in backwashing cleaning position.
• Put back
ON
in the filtration pump. Control the time that lasted the backwash cleaning on the clock display. Make sure it has made adequate and
complete backwash of your filter.
• When finished the backwashing cleaning, again turn
OFF
the filtration pump and put back the valve in the filtering position. If you wish, now you
can perform a rinse cycle.
• Proceed as backwashing cleaning, this time placing the filtration pump valve in the rinsing position.
• When leaving the Filter Cleaning menu, the system will be back to the previous programmed mode.
5.3
Automatic (or with timer):
In this mode the filtration is switched in accordance with a timer that allow to adjust the start and end of the filtration. Timers always operate daily, in
cycles of 24 hours.
To set the
ON/OFF
times (up to 3 possible time programmable), select with the
up/down
keys in the timer line you want to change (1-3 ).
The
plus/minus
keys opens the selected start time field. Set the time with
plus/minus
keys. Scroll with the
up
key to the minute field and set it up
with
plus/minus
keys. To confirm press
OK
and to cancel press
return/scape
. To set the
OFF
timer, proceed accordingly.
See section
Filter Cleaning
below.
5.4
Smart*:
This mode uses, as a basis, the automatic or timer mode, with its 3 intervals of filtration, but adjusting the filtration time in function of the
water temperature. For that reason 2 parameters of temperature are provided: The maximum temperature, from which on the filtration times will be the
ones from the timer setting. The minimum temperature: below this value the filtration time will be reduced to 5 minutes, which is the minimum working
time. Between these 2 temperatures the filtration times will climb linearly.
Use the
plus/minus
keys to set the desired minimum and maximum temperatures.
There is an option to activate the antifreeze mode in which the filtration will start if the water temperature is below 2° C.
To set the
ON/OFF
times (up to 3 possible time programmable), follow the instructions of the
Automatic Mode.
See section
Filter Cleaning
below.
5.3
5.4
Содержание AquaRite UV LS
Страница 66: ...66 Notes ...
Страница 67: ...67 Notes ...
Страница 68: ...Hayward is registered trademark of Hayward Industries Inc 2021 Hayward Industries Inc ...