![Hayward AquaRite UV LS Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/hayward/aquarite-uv-ls/aquarite-uv-ls_owners-manual_2111054011.webp)
11
GENERAL INSTALLATION GUIDE
DOMESTIC & INDUSTRIAL DEVICES
2.
MAIN SCREEN
PLUS
key
Modify value/selection
MINUS
key
Modify value/selection
OK
key
Select/confirm
UP
key
Navigation up
DOWN
key
Navigation down
RETURN/ESCAPE
key
For complete technical information of your device, access the following link:
www.smartswim.net
Current time
Ultraviolet
ON/OFF
(according to model)
Hydrolysis / Electrolysis
Production intensity in %
(hydrolysis)
and gr/h
(electrolysis)
Cu/Ag Ionization
(according to model)
Intensity en mA
Communication display – mother board
red
indicates communication error
Heating
ON/OFF
Manual
Automatic
Heating
Smart
Intelligent
Boost
man
aut
hea
smt
int
bst
State filtration relay
(see section 5- Filtration)
Automatic measurements:
pH/redoX/
free chlorine/conductivity
(according to options)
State relay lighting
Manual / Automatic
man
aut
Water temperature
Polarity 1 /
Polarity 2
Filtration stopped due to lack of water flow
Waiting time
Cover
Pol 1
Flow
Low
---
Pol 2
Production automatically reduced to
the % selected
(see display
3.6
)
Lack of conductivity or salt / low water temperature /
scale on cell / exhausted cell
(check working hours)
Pr on
Polarity 1 /
Polarity 2
Pol 1
Pol 2
Ionizer timer
7.5
7.0
ON/OFF
Setpoint pH maximum (acid control)
Setpoint pH minimum (base control)
Function of acid pump and base pump
AL3
Maximum dosing time exceeded
(
to reset the alarm)
Flow alarm
700
FL 1
ON/OFF
Function of chlorine pump
Setpoint redoX minimum
AL3
Maximum dosing time exceeded
(
to reset the alarm)
Flow alarm /
Error rotameter Cl
2
AL3
FL 1
1.00
FL 2
Setpoint Free Chlorine minimum
Maximum dosing time exceeded
(
to reset the alarm)
Status of the auxiliar relays
TANK
Low level chemical tank
1.
ELECTRONIC BOX ELECTRICAL CONNECTIONS
AUX 4
Heating control
15
&
16
LIGHT
Lighting control
11
&
12
AUX 2
redoX / free chlorine
ppm’s (pump)
5
&
6
Ground
AUX 1
Ultraviolet
3
&
4
DRY CONTACT
110-230V max. 3.15A Ground
CONNECT ALL THE SENSORS CAREFULLY, A
BAD CONNECTION MAY CAUSE IRREPARABLE
DAMAGE TO THE DEVICE
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
1
4
1
2
5
3
6
7
8
2
1 2 3 4
3
3
3
3
4
4
4
4
1
1
1
1
2
2
2
2
1 2 3
Conductivity probe
1
yellow
2
transparent
Cover
1
&
5
Ionization
7
&
8
(according to model)
Chlorine probe
detector
FL2
(rotameter)
Flow switch
FL1
2
&
5
Acid deposit
level
TANK
4
&
5
Temperature probe
3
black
5
brown
6
blue
1
red
2
yellow
3
black
Free Chlorine
3
red
4
black
FILTER PUMP
Filtration control
9
&
10
14
12
11
L
N
A1 A2
AUX 3
13
&
14
Variable speed pump
Connection remote display*
Connection WIFI module
Device control SLAVE
*I n case of connecting 2
display´s on the device,
remember not to connect
the remote display in this
communication channel.
Use the “EXTERN” channel
instead.
1
slow
2
medium
3
fast
4
common
1
red
2
yellow
3
green
4
black
1
red
2
yellow
3
green
4
black
1
brown
2
blue
pH
redoX
pH
pH Control
1
&
2
Содержание AquaRite UV LS
Страница 66: ...66 Notes ...
Страница 67: ...67 Notes ...
Страница 68: ...Hayward is registered trademark of Hayward Industries Inc 2021 Hayward Industries Inc ...