Input Power For stand alone operation:
AQR15CUL, AQR9CUL, AQR3CUL
- Refer to the wiring label on the AquaRite as well as the diagram
below to determine correct wiring connections. The AquaRite is shipped from the factory with the
configuration jumpers in 240VAC position. If using 120VAC, move the jumpers as shown below. For
Canadian models, the AquaRite shall be connected to a circuit protected by a class A ground fault
interrupter. Be sure to connect the ground wire to the green ground screw terminal located on the
bottom of the enclosure.
AQR15XLCUL, AQR9CXLCUL, AQR3XLCUL
- These models are designed to use 120 VAC only. The
120 VAC line cord must be plugged into a GFCI receptacle or a receptacle protected by a Class A
ground fault interruptor. See diagram below.
Bonding:
Lugs used for bonding are attached to the bottom of the Aqua Rite enclosure. Connect to
the pool bonding system using minimum 6AWG copper wire.
Electrolytic Cell and Flow Switch:
The electrolytic cell and flow switch cables are terminated with
connectors which plug into the AquaRite, for easy attachment and removal. The door of the AquaRite
must be open to access the cell cable connector. The flow switch plugs into a connector (similar to a
AQUA
RITE
AQUA
RITE
SUBPANEL
GFCB
PCB
PCB
BONDING
LUG
BONDING
LUG
BONDING
LOOP
PUMP
GROUND
GND
GND
IMPORTANT:
MOVE JUMPERS
TO POSITIONS SHOWN
TYPICAL 240 VAC WIRING
120 VAC
Aqua Rite
SUBPANEL
GROUND
NEUTRAL
GFCI
OUTLET
BONDING
LOOP
PUMP
13