background image

7

8

NO FLOW  

When illuminated, the flow switch has detected no flow and the Aqua

Trol

®

 has stopped generating chlorine.  A flashing LED indicates a 15/60 second

time delay period.

TEST SALT LEVEL  

When flashing, the salt level is low (below 2700ppm) and

Aqua Trol is generating at low efficiency.  When illuminated steady, the salt level

is too low and Aqua Trol has shut down.  Before adding large quantities of salt, it

is advisable to have your salt level professionally checked.

HIGH SALT  

When illuminated, the salt level is too high and Aqua Trol has shut

down.

INSPECT CELL  

A flashing indicator signifies that either the cell efficiency is

reduced or that it is time for regularly scheduled cell inspection.  In either case,

inspect the cell and clean if necessary.  Pressing the "diagnostic" button next to

the display for 3 seconds will stop the flashing LED.  When illuminated steady,

cell efficiency is greatly reduced and the Aqua Trol has stopped producing chlo-

rine.  Inspect, clean or replace if necessary.

Salt Display

The Salt Display shows the current salt concentration of the pool water.  Readings are

in ppm (parts per million).  Refer to the Water Chemistry section for recommended salt

levels as well as how to add/remove salt.

The factory default display is in English (ppm).  If Metric units (grams per liter) are

preferred,  push the "diagnostic" button next to the display once.  The display will

now show the pool water temperature in degrees Fahrenheit.  With the temperature

displayed, move the main switch from AUTO to SUPER CHLORINATE to AUTO.  The

temperature display will instantly change to degrees Celsius and the salt display will

switch to grams/liter.  Repeat this process to switch back to English units (ppm and

Fahrenheit).

Operation

By understanding how the Aqua Trol operates, you'll be sure to use it more effec-

tively for maximum convenience and performance.  Assuming that the water chemical

levels are in the recommended range, there are three factors that you can control

which directly contribute to the amount of chlorine the Aqua Trol will generate:

1. filter time each day (hours)

2. the amount of salt in the pool

3. the "Desired Level %" setting

To find the optimum "Desired Level %" setting, start at a fairly high setting and work

downward.  It will take a few days of adjustments to find the ideal setting for your

pool/spa.  Once determined, it should only take minor adjustments, if at all, to com-

pensate for differing salt levels due to splashing, backwashing, rain, etc.  Because the

production of chlorine is affected by water temperature, it is important to check chlo-

rine levels during periods of unusually high or low pool water temperatures.  The

Aqua Trol control will not produce chlorine at temperatures below 50º F.  If your pool

will be below this temperature for any length of time, you must chlorinate manually.

NOTE: After the ideal "Desired Output %" setting has been found, you may need to

raise the setting when the pool water temperature increases significantly, when there

is higher than normal bather load or when your chlorinator cell ages.  You may need to

lower the setting when the pool water temperature decreases significantly or there are

long periods of inactivity.

Maintaining the Aqua Trol

®

 System

To maintain maximum performance, it is recommended that you open and visually

inspect the cell every 3 months or after cleaning your filter.  The Aqua Trol will

remind you to do this by flashing the "Inspect Cell" LED after approximately 500

hours of operation.  After you inspect the cell (and clean, if necessary) press the

small "diagnostic" button next to the display for 3 seconds to stop the flashing

"Inspect Cell" LED and start the timer for the next 500 hour inspection period.

The Aqua Trol electrolytic cell has a self cleaning feature incorporated into the

electronic control’s logic.  In most cases this self cleaning action will keep the

cell working at optimum efficiency.  In areas where water is hard (high mineral

content) and in pools where the water chemistry has been allowed to get "out of

balance", the cell may require periodic cleaning.  The "Inspect Cell" LED will

indicate if cell efficiency is decreased and servicing is necessary.  If the "Inspect

Cell" LED remains on after a thorough cleaning, the cell may be worn and re-

quire replacement.

Servicing and Cleaning the Aqua Trol cell

Turn off power to the Aqua Trol before removing the electrolytic cell.  Once

removed, look inside the cell and inspect for scale formation (light colored crusty

or flaky deposits) on the plates and for any debris which has passed through the

filter and caught on the plates.  If no deposits are visible, reinstall.  If deposits are

seen, use a high pressure garden hose and try to flush the scale off.  If this is not

successful, use a plastic or wood tool (do not use metal as this will scratch the

coating off the plates) and scrape deposits off of the plates.  Note that a buildup

on the cell indicates that there is an unusually high calcium level in the pool (old

pool water is usually the cause).  If this is not corrected, you can expect to have to

periodically clean the cell.  The simplest way to avoid this is to bring the pool

chemistry to the recommended levels as specified.

Mild Acid Washing: 

 Use only in severe cases where flushing and scraping will

not remove the majority of deposits.  To acid wash, turn off power to Aqua Trol.

Remove cell from piping.  In a clean plastic container, mix a 4:1 solution of water

to muriatic acid (one gallon of water to one quart of muriatic acid).  ALWAYS

POUR ACID INTO WATER - NEVER POUR WATER INTO ACID.  Be sure to

wear rubber gloves and appropriate eye protection.  The level of the solution in

the container should just reach the top of the cell so that the wire harness com-

partment is NOT submerged.  It may be helpful to coil the wiring before immers-

ing the cell.  The cell should soak for a few minutes and then rinse with a high

pressure garden hose. If any deposits are still visible, repeat soaking and rinsing.

Replace cell and inspect again periodically.

Winterizing

The Aqua Trol electrolytic cell and flow detection switch will be damaged by

freezing water just as your pool plumbing would.  In areas of the country which

experience severe or extended periods of freezing temperatures, be sure to drain

all water from the pump, filter, and supply and return lines before any freezing

conditions occur.  The electronic control is capable of withstanding any winter

weather and should not be removed.

Spring Start-up

DO NOT turn the Aqua Trol on, until the pool water chemistry has been brought

to the proper levels.  This information can be found on page 2.

Содержание Aqua Trol AQ-TROL-HP

Страница 1: ...ut to r desired output OR increase or p filtration time soda ash muriatic acid uired to increase da to increase cid to increase increase n in manual NT REQUIRED water to decrease quired to decrease AQ TROL RJ AQ TROL RJ TL AQ TROL HP AQ TROL HP TL 092016K RevL right 2010 Hayward Inc www haywardnet com Aqua Trol ...

Страница 2: ...rovided in the elec tric supply service panel with a continuous copper wire equivalent in size to the circuit conductors sup plying the equipment One bonding lug for US models two for Canadian models is provided on the external surface To reduce the risk of electric shock connect the local common bonding grid in the area of the swimming pool spa or hot tub to these terminals with an in sulated or ...

Страница 3: ...ion products for and applies only to the of of purchase is not the date of installation e place of purchase or r more information on hnical Service Support e Goldline web site at net com of installation on pools larger than the oduct s in accordance n accordance with the nauthorized repairs or of natural stone used in ECONSTITUTETHE NTIFIEDHAYWARD ODUCTSAND IS IN INCLUDINGWAR ICULAR PURPOSE ANDYOU...

Страница 4: ...d Aqua Trol version no option designation or may be made via a 120V 20A twist lock linecord and receptacle when the TL version is ordered AQ Trol HP Straight blade 120V 15A linecord receptacle 2 51mm rigid PVC piping or 1 1 38 32mm flexible hose AQ Trol HP TL Twist lock 120 20Alinecord receptacle 2 51mm rigid PVC piping or 1 1 38 32mm flexible hose AQ Trol RJ Straight blade 120V 15A linecord recep...

Страница 5: ...e water If the Si is above 0 2 scaling and staining will occur Use the equation and chart below to determine the saturation index 2 ºC ºF Ti Calcuim Hardness Ci Total Alkalinity Ai 53 60 66 76 84 94 103 12 16 19 24 29 34 39 3 4 5 6 7 8 9 How to use Measure pool pH temperature calcium hardness and total alkalinity Use the chart above to determine Ti Ci and Ai from your measurements Insert values of...

Страница 6: ...It is also acceptable to use water conditioning salt pellets how ever it will take longer for them to dissolve Do not use rock salt salt with more than 1 yellow prussiate of soda salt with more than 1 of anti caking additives or iodized salt How to Add or Remove Salt Turn the filter pump on and add the salt directly into the pool Brush the salt to speed up the dissolving process to not allow the s...

Страница 7: ... 27 32 80 36 90 41 93 42 107 48 120 55 2200 3000 2800 2400 3200 Ideal Ideal Ideal Ideal 2600 3400 OK OK OK OK OK OK OK POUNDS and Kg OF SALT NEEDED FOR 3200 PPM 3600 Dilute Dilute Dilute Dilute 10 000 8 000 6 000 37 500 213 160 267 97 73 121 200 150 250 91 69 114 187 140 233 85 64 106 173 130 217 79 59 98 160 120 200 73 55 91 147 110 183 67 51 83 133 100 167 61 46 76 120 90 150 55 41 68 107 80 133...

Страница 8: ...er the h Tighten all union n FROM PU FROM PU POUNDS and Kg OF STABILIZER CYANURIC ACID NEEDED FOR 80 PPM Gallons and Liters of Pool Spa water Current Stabilizer Level ppm 0 ppm 20 ppm 60 ppm 30 ppm 40 ppm 50 ppm 70 ppm 80 ppm 10 ppm 12 000 45000 8 000 30000 6 000 22500 14 000 52500 10 000 37500 16 000 60000 18 000 67500 8 0 3 6 5 3 2 4 4 0 1 8 8 0 3 6 9 4 4 3 6 7 3 0 9 4 4 3 10 7 4 9 12 0 5 4 7 0 ...

Страница 9: ... you have an abnormally high bather load a large amount of rain a cloudy water condition or any other condition which needs a large amount of purification to be introduced put the Main Switch in the SUPER CHLORINATE position This electronically super chlorinates shocks the water for 24 hours filter pump must be on during this time or until the power has been turned off whichever comes first At the...

Страница 10: ...ol which directly contribute to the amount of chlorine the Aqua Trol will generate 1 filter time each day hours 2 the amount of salt in the pool 3 the Desired Level setting To find the optimum Desired Level setting start at a fairly high setting and work downward It will take a few days of adjustments to find the ideal setting for your pool spa Once determined it should only take minor adjustments...

Страница 11: ...inspect for scale formation light colored crusty or flaky deposits on the plates and for any debris which has passed through the filter and caught on the plates If no deposits are visible reinstall If deposits are seen use a high pressure garden hose and try to flush the scale off If this is not successful use a plastic or wood tool do not use metal as this will scratch the coating off the plates ...

Страница 12: ... page 2 for recommended chemical levels The pool s chemistry must be balanced BEFORE activating theAqua Trol NOTE If the pool does not have new water add 1 quart 1 liter of metal remover and 1 quart 1 liter of non copper based algaecide to the pool per manufacturers instructions This ensures a quick troublefree transfer to the Aqua Trol system Mounting theAqua Trol Control The Aqua Trol is contain...

Страница 13: ...on tail piece and install them in the hose tailpieces Tighten all union nuts BY HAND for a watertight seal Return Jet installation RJ option Unscrew the the hose adaptor from the pool return jet fitting and in its place screw in the right angle cell mounting adaptor Note that this installation does NOT require a flow switch however it is very important that the cell be mounted vertically directly ...

Страница 14: ...ol must be properly grounded and bonded Input Power Models with the standard 120 VAC line cord should be plugged into a GFCI recep tacle Twist lock models should be plugged into a twist lock receptacle wired to a GFCI circuit breaker For Canadian installations Connect to a circuit protected by a Class Aground fault interruptor See diagram below SUBPANEL SUBPANEL GROUND GROUND NEUTRAL NEUTRAL GFCI ...

Страница 15: ...sing minimum 8AWG copper wire if required by code Pump Output The Aqua Trol s filter pump output is rated at 120 VAC 15 A max Check the electrical rating marked on the pump motor Connecting a pump with a higher amperage rating may result in permanent damage to the Aqua Trol The 120 VAC standard or twist lock pump receptacle is located outside on the bottom of the enclosure Electrolytic Cell and Fl...

Страница 16: ... back to the standard salt display CommonProblemsandSolutions 1 Power LEDnoton Check to make sure 120VAC input power is connected to the Aqua Trol control Verify input voltage with a voltmeter If there is input power the fuse may have blown TheAqua Trol is protected by a 20 amp miniATO fuse located on the circuit board above the cell connector 2 Filterpumpnotrunning Check that the time clock manua...

Страница 17: ...fresh water Continue until the salt concentration is at recommended levels 8 Inspect Cell LED flashing Inspect and clean cell according to directions on page 8 When done press the diagnostic button for 3 seconds to stop the Inspect Cell LED flashing 9 InspectCell LEDilluminated Remove and inspect the cell for scale If the cell is scaled follow the directions on page 8 for cell cleaning If the pool...

Страница 18: ...RRANTYEXCLUSIONS 1 Material supplied or workmanship performed by others in process of installation 2 Damage resulting from improper installation including installation on pools larger than the product rating 3 Problems resulting from failure to install operate or maintain the product s in accordance with the recommendations contained in the owners manual s 4 Problems resulting from failure to main...

Страница 19: ... permit ey are closely th Ground is t To reduce must be con ed in the elec nuous copper nductors sup for Canadian surface To nect the local he swimming ls with an in smaller than such as rails ware within 3 all be bonded copper con US 6 AWG CTIONS 16 ...

Страница 20: ...ease or decrease pump filtration time Too low add soda ash Too high add muriatic acid Alkalinity 80 120 ppm Salt 2700 3400 ppm Add salt as required to increase Add baking soda to increase Stabilizer 60 80 ppm Add cyanuric acid to increase Calcium 200 400 ppm Add calcium to increase Electrolytic Cell inspect clean Refer to section in manual TEST IDEAL RANGE ADJUSTMENT REQUIRED Drain and add water t...

Отзывы: