background image

Within range of base station:

  The wireless remote display/keypad must be

used within 250 ft. (assuming the signal will have to travel through walls) or

500 ft. (line of sight) from the AQL2-BASE-RF Base Station which is typically

mounted on the Pro Logic/Aqua Logic  main control unit at the pool equip-

ment pad.  The base station can also be mounted up to 500 ft. away from the

main control unit to shorten the distance between it and any wireless remote.

See the "Remote Mounting of the Base Station" section of the base station

manual for more details.

2.

Powering the AQL2-Tx-RF-PS-x/AQL2-Tx-RF-P-4:

   These models use a re-

chargeable built-in battery pack which will require an initial charge when you

first receive the unit.  Charge the unit for at least 15 hours before attempting to

use it without the charger.  Note that both units can be used normally while

connected to the charger.

Charging the battery:

Plug the included wall mount charger into a standard 120VAC wall outlet,

away from the pool area. It is not recommended that you use an extension

cord with this product.  Plug the power connector into the rear of the AQL2-

Tx-RF-PS-x or AQL2-Tx-RF-P-4 and charge for 15 hours.  A fully charged

battery will provide over 400 one-minute uses under typical conditions.

About battery power:

When the charger is not plugged into the AQL2-Tx-RF-PS-x or AQL2-Tx-RF-

P-4, the unit uses  battery power and will take steps to extend battery life.

After one minute of no button presses by the user, the unit will show a brief

display and  will go into "sleep" mode (pg. 5).  To wake it up, simply press

any button on the keypad.  The button press will not perform any function

except waking the unit.  Once awake, any subsequent button presses will

perform their normal functions.

When the charger is plugged in, the unit uses wall power while it also charges

the battery.  It will always be "awake", as long as it's plugged into the

charger.

Note that the battery will slowly lose charge if the unit is not plugged into

the wall, even if it is not used.  The battery will need to be charged every 1 -

2 months, depending on usage.

The AQL2-Tx-RF-PS-x and AQL2-Tx-RF-P-4 will display a series of informa-

tion about its status and the status of the battery.   Refer to the "Operation"

section of this manual for an explanation of each of these displays.

3

10.  

Teach Wireless Fail.

Please try again.

This is usually caused by a button being held down for more than 3 seconds,

falsely triggering the Teach Wireless mode. It can also be displayed if the Pro

Logic/Aqua Logic  is not in the Teach Wireless mode. If the Pro Logic/Aqua

Logic  is in Teach Wireless, then the radio signal may be too weak—try moving

closer to the Pro Logic/Aqua Logic  main control unit base station.

 

11.

Display Error 1

call 888-921-7665

Display Error 2

call 888-921-7665

Display Error 4

call 888-921-7665

An internal problem has occurred in the wireless remote display/keypad.   Re-

move the display/keypad from the wall mount base (see diagram on page 2) and

write down the model number and serial number.  Call the Hayward Tech support

department (Monday through Friday, from 8AM to 8PM eastern time) to find out

how to obtain a replacement wireless remote display/keypad.

8

Содержание AQL2-WB-RF-PS-4

Страница 1: ...here is no guarantee that interference will not occur in a particular installation If this equip ment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between...

Страница 2: ...s in materials and workmanship under normal use and service for a period of one 1 year These warranties are applicable from the initial date of installation on private residential swimming pools in the US and Canada Hayward Goldline warrants all the above identified pool automation and chlorination prod ucts installed on commercial swimming pools and on swimming pools outside of the US and Canada ...

Страница 3: ...Select Location Because both models are battery operated and designed to be portable there are no power supply or mounting concerns like the wall mount units The table top units are intended to be used in the normal living space with these considerations Protected from the weather The wireless remote display keypad should be used indoors or in a weather protected area rain should never hit the wir...

Страница 4: ... show a brief display and will go into sleep mode pg 5 To wake it up simply press any button on the keypad The button press will not perform any function except waking the unit Once awake any subsequent button presses will perform their normal functions When the charger is plugged in the unit uses wall power while it also charges the battery It will always be awake as long as it s plugged into the...

Страница 5: ...te that this selection applies to this wireless remote display keypad only Repeat the process of each display keypad in the system 6 Display backlight always on Models running off wall power The display backlight should always illuminate when you press any key on the unit If it remains on after 60 seconds have elapsed since the last button push you can stop this by pressing the menu key possibly m...

Страница 6: ...connected to the charger TROUBLESHOOTING 1 Can t find the Teach Wireless display From the Pro Logic Aqua Logic con trol or any direct wired display keypad press the menu button possibly more than once until Settings Menu is displayed Next press the or but tons possibly more than once until the Teach Wireless display appears If you get to the point where Settings Menu appears again then this means ...

Отзывы: