USE ONLY GENUINE REPLACEMENT PARTS
Page 4 of 5
Salt & Swim 2.0
Rev. A
6. ELECTROLYSIS (from 3 g salt/L)
5. ELECTRICAL CONNECTIONS TO ELECTRONIC BOX
4. ASSEMBLY AND CONNECTION OF THE CELL
Step 1:
Install the cell in a vertical position.
Step 2:
Install the cell on by-pass.
Step 3:
Install the cell at the highest point of the installations.
Step 4:
Connect the cell and the gas detector to the electronic
box.
N.B.:
If the unit is being installed for a pool that has already
been treated with chlorine, we recommend total renewal of all
water in the pool so that the cyanuric acid (chlorine stabiliser)
does not distort measurements made by the rX (redox) probe.
During normal operation, the LEDs light up blue.
The equipment has 5 production levels, with each level featuring 2 LEDs.
Adjust the production, in grams of chlorine/hour, using the buttons ‘+’ and ‘-’.
The levels increase in increments of 20%.
Example :
For a 22 Gr Cl2/h unit:
Selected level(s)
% of production
g Cl2/h
1
20 %
4.4 g Cl2/h
3
60 %
13.2 g Cl2/h
5
100 %
22 g Cl2/h
Connect all the sensors carefully, a bad
connection may cause irreparable damage to
the equipment.
COVER
&
FLOW SWITCH
FL1
&
Cell
Probes
OPTIONAL