background image

Page 2 of 8                                                

MODEL S180T, S180T90

                                         IS180T90 Rev C 

WWW.HAYWARDPOOL.COM

            USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

 

 

 - 

WARNING

 - 

Read and follow all instructions in this owner’s manual and on the 

equipment. Failure to follow instructions can cause severe injury and/or death

.

 

 

 

 

 WARNING – 

Suction Entrapment Hazard.

  

Suction in suction outlets and/or suction outlet covers which are, damaged, broken, cracked, missing, or 
unsecured can cause severe injury and/or death due to the following entrapment hazards: 

Hair Entrapment

Hair can become entangled in suction outlet cover.

 

Limb Entrapment

A limb inserted into an opening of a suction outlet sump or suction outlet cover that is 

damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb.

 

Body Suction Entrapment

-

 A negative pressure applied to a large portion of the body or limbs can result in an 

entrapment.  

Evisceration/ Disembowelment 

A negative pressure applied directly to the intestines through an unprotected suction 

outlet sump or suction outlet cover which is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ 
disembowelment. 

Mechanical Entrapment

There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in 

an opening of a suction outlet cover resulting in mechanical entrapment.

 

 

 

WARNING

 - 

To Reduce the risk of Entrapment Hazards: 

o

 

When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets 
per pump must be installed.  Suction outlets in the same plane (i.e. floor or wall), must be installed a 
minimum of three feet (3’)  [1 meter] apart, as measured from near point to near point. 

o

 

Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. 

o

 

Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 

o

 

The maximum system flow rate shall not exceed the flow rating of as listed on Table 1. 

o

 

Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. 

o

 

Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. 

o

 

In addition two or more suction outlets per pump installed in accordance with latest NSPI, IAF Standards and CPSC guidelines, 
follow all National, State, and Local codes applicable. 

o

 

Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.

 

 

 

WARNING

 –

 

Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa 

from the suction outlets can result in an increase potential for suction entrapment as described above. 

 

WARNING

 – 

Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper 

and other material can result in an increase potential for suction entrapment as described above. 

 

WARNING

 – 

Suction outlet components have a finite life, the cover/grate should be inspected frequently 

and replaced at least every ten years or if found to be damaged, broken, cracked, missing, or not securely attached.

 

 

CAUTION

 –

 

Components such as the filtration system, pumps and heater must be positioned so as to 

prevent their being used as means of access to the pool by young children.

  

 

WARNING

 – 

Never operate or test the circulation system at more than 30 PSI. 

 

CAUTION – 

All

 

electrical wiring MUST be performed by a qualified professional, and MUST conform to 

local codes and regulations.

  

 

Содержание S180T PRO Series

Страница 1: ...e alert to the potential for personal injury WARNING warns about hazards that could cause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or property damage and if ignored presents a potential hazard It can also make consumers aware of actions that are unpredic...

Страница 2: ...rt as measured from near point to near point o Dual suction fittings shall be placed in such locations and distances to avoid dual blockage by a user o Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas o The maximum system flow rate shall not exceed the flow rating of as listed on Table 1 o Never use Pool or Spa if any suction outlet component is...

Страница 3: ...tor can cause serious or fatal electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections Your Hayward Pro Series high rate sand filter is a high performance totally corrosion proof filter that blends superior flow characteristics and features with ease of operation It repr...

Страница 4: ...f Carefully start the threaded Elbow adapter 11 into the Control Valve 1 port marked PUMP and hand tighten Further tightening may not be needed to make a leak proof joint However never tighten more than to 1 turns past hand tight to avoid failure due to over tightening the joint g Place two hose clamps 14 over clear hose 13 Fit hose over straight and elbow adapters and secure with the clamps HINT ...

Страница 5: ...RT VALVE 1 2 ECX27081 PRESSURE GAUGE 1 3 GMX600F VALVE TANK O RING 1 4 GMX600N FLANGE CLAMP VALVE TANK 1 5 SX202S SAND SHIELD 1 6 SX180DA LATERAL ASSEMBLY W PIPE 1 7 SX180AA2 FILTER TANK W LATERAL ASSY 1 8 SX200QN LATERAL ONE PIECE 10 9a SX180HG DRAIN CAP ASSY 1 5 16 DIA 9b SX180LA DRAIN CAP ASSY 1 3 4 DIA 1 10 SX180K SYSTEM MOUNTING BASE 1 11 SPX11050Z4 1 ELBOW ADAPTER 1 12 SPX1091Z2 1 STRAIGHT H...

Страница 6: ...yward Pool Products Inc 620 Division Street Elizabeth New Jersey warrants its products free from defects in materials and workmanship for a period of ONE 1 year from the date of purchase Parts which fail or become defective during the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days...

Страница 7: ... long enough each day to obtain at least one complete turnover of your pool water To properly sanitize your pool maintain a free chlorine level of 1 to 3 ppm and a pH range of 7 2 to 7 6 Insufficient chlorine or an out of balance pH level will permit algae and bacteria to grow in your pool and make it difficult for your filter to properly clean the pool water PROBLEM SOLVING LIST LOW WATER FLOW SH...

Страница 8: ...______________________ Product Serial No _______________________________________ Please send me more information on these other New Installation Replacement products from Hayward Type of Above ground Pool Pump Filter Automatic Pool Cleaner Light Vinyl Fiberglass Other Chlorinator Skimmer Heater Heat Pump Salt Chlorine Generator Controls May we contact you for future product promotions and offering...

Отзывы: