Haysys PIU Скачать руководство пользователя страница 24

 

Page 24 of 31 

PHA

SE 

ID

ENT
IFI

CA

TI

O

U

NI

T

   

 

HAY

SY

S L

IM

ITE

D

 

The Remote Reference Unit also communicates with the GPS Satellites to obtain the 1-second 

timing reference and as such the Remote Reference Unit is supplied with an external GPS 

Antenna that must be positioned such that GPS Satellite Communications is achieved. 

The Internet connected PC also contains Data Logging software (supplied), that will allow the 

capture to file, of data from PIU units (see section 9). 

Содержание PIU

Страница 1: ...HAYSYS Limited 2018 www haysys co uk TD00040 HAYSYS LIMITED PHASE IDENTIFICATION UNIT PIU USER MANUAL...

Страница 2: ...OF OPERATION 11 5 1 General Operation 11 5 2 Location of the Remote Reference Unit 12 6 USING THE PIU 13 6 1 Checking the battery charge state 13 6 2 Turning the Unit On 13 6 3 Turning the Unit Off 1...

Страница 3: ...Carry Case 30 13 2 In Car Charger 30 13 3 E Field Probes 30 14 WARRANTY AND SUPPORT 31 LIST OF TABLES Table 1 Table of Buttons and Indications 9 LIST OF FIGURES Figure 1 Operators Guide attached to th...

Страница 4: ...g the PIU Utility warning 22 Figure 18 Remote Reference Unit Configuration 23 Figure 19 Charging via the USB 26 Figure 20 PIU and Reference Dimensions 27 Figure 21 Connector Cover Release 28 Figure 22...

Страница 5: ...the phase of the radiated E Field 1 2 Lithium Ion Battery Please observe the following warnings as the PIU battery contains lithium that may cause heating rupture or ignition if not used correctly TH...

Страница 6: ...E Field Probe Part Number 148 152YAGI 2 2 PIU Shipping Mode Whilst in this mode the PIU will be unresponsive to any button presses as the battery is disconnected for storage and shipping When the PIU...

Страница 7: ...s a short press of that button while a line underneath the F character and the following character indicates a press of three seconds or more is required Figure 1 Operators Guide attached to the under...

Страница 8: ...s co uk 3 3 3rd Level This Manual The final level of documentation is this manual which is also available as a pdf download from our website www haysys co uk 3 4 On line Training Videos HAYSYS is plea...

Страница 9: ...ds F2 a Turn off when pressed with F1 for more than 3 seconds b Set Phase reference Short press c Cycle the phase reference Hold for more than three seconds and then simultaneously short press on F3 F...

Страница 10: ...Page 10 of 31 PHASE IDENTIFICATION UNIT HAYSYS LIMITED Figure 3 Front Panel Buttons F1 F4 Amber LEDs D1 and D2 Green LEDs Phase Indication Vectors F1 F4 Buttons...

Страница 11: ...re the instantaneous phase of the electrical field being radiated by any property The original source of this radiation does not have to be the properties internal electricity meter but can be any liv...

Страница 12: ...e data upload 51 30 11239 N 03 07 14367 W HAYSYS Cardiff It also includes the instantaneous phase and the reference phase 050 L2 in this case 5 2 Location of the Remote Reference Unit Traditionally ot...

Страница 13: ...re the GPS position 6 4 Setting the Reference Phase If the unit has had its reference phase cleared either by the battery becoming discharged or being cleared by the user then all three phase vectors...

Страница 14: ...close as possible to the property or equipment where the single phase is being determined If the unit can identify the phase of the measured E Field then it will illuminate the corresponding phase ve...

Страница 15: ...ng all of the reference data and GPS information then the unit displays operate in the same way as when the unit is in User Mode However should the unit not be working correctly then this mode provide...

Страница 16: ...ermined Lost communications with the Remote Reference Unit is indicated by the inner portion of the three phase vectors lighting in turn and showing a rotating action 6 9 3 No GPS Signal If the unit h...

Страница 17: ...PIU has a full speed USB 2 0 Interface located under the connection cover as shown in Figure 7 below Figure 7 Charging and USB Connector The PIU can be charged from either the Charging Power Socket or...

Страница 18: ...d power up into its configuration mode as indicated by F4 staying on The unit may now be plugged into the host PC using the supplied USB cable On checking the Device Manager of the Host PC that the PI...

Страница 19: ...emote Reference Unit RRU to be used with the PIU Press the Save button and ensure that the button changes to the green colour as shown in Figure 10 below Figure 10 IP Address details entered and saved...

Страница 20: ...be running on the Host PC at all times when the PIU units are being used in the field As with the PIU configuration procedure connect the RRU to the host PC via the supplied USB cable Start the PIU u...

Страница 21: ...an internal IP address Press the Save button and confirm that the green colour is shown Next activate the bridge server by pressing the Bridge Inactive button which will respond by the button text ch...

Страница 22: ...d by clicking on the cross in the red box in the top right corner There will be two warnings shown the first is shown in Figure 16 below asks if the application should be minimised or closed The secon...

Страница 23: ...ith this Remote Reference Unit The Remote Reference Unit is for indoor use only If required a Remote Reference Unit can be supplied and installed within the customer s own premises The Remote Referenc...

Страница 24: ...in the 1 second timing reference and as such the Remote Reference Unit is supplied with an external GPS Antenna that must be positioned such that GPS Satellite Communications is achieved The Internet...

Страница 25: ...g software can capture the raw data from any connected PIU and its reference for subsequent processing This information includes the GPS position of the PIU at the time of the F1 button press along wi...

Страница 26: ...polarity Figure 19 Charging via the USB The PIU is fitted with a Micro USB connector that in addition to providing communications to a USB Host can also be used to charge the unit The charging circuit...

Страница 27: ...ng the battery 12 1 Environmental Protection The PIU is rated to IP65 when the connector cover is secured in place This protects the unit from both dust and water splash ingress The unit should only b...

Страница 28: ...access to the Mains charger connector the USB connector and the SIM card holder 12 3 Insertion and Removal of SIM Card The PIU uses a standard size SIM card that is inserted into the SIM Card Holder...

Страница 29: ...Page 29 of 31 HAYSYS LIMITED PHASE IDENTIFICATION UNIT Figure 23 SIM Card Holder PIU connection cover removed SIM Card Holder...

Страница 30: ...TIONS 13 1 Carry Case Not Yet Available 13 2 In Car Charger Not Yet Available 13 3 E Field Probes The E Field Probe is available as a flexible fixed length insulated Probe 47 cms in length The probe i...

Страница 31: ...PIU units are supplied with a 24 month parts and labour warranty as standard Should you have any issues with your unit s support can be requested directly from HAYSYS Limited by emailing help haysys c...

Отзывы: