RECOMMENDED TOOLS

:  T-20 Torx driver, level, flathead screwdriver, Phillips #3 

screwdriver. 

RECOMMENDED PARTS (NOT SUPPLIED)

: 8-12 #6 sheet metal screws, ½” screwdriver 

stop, 3/8” tubing, 6 1/8” x 3” zinc-plated steel toggle bolts, 6 zinc-plated steel 1/8” female 
washers.

 

LOCATION OF UNIT:

 When installing this unit, local, state or federal codes should be 

adhered to. If height other than shown is required, then dimensions must be adjusted 
accordingly.  This unit is intended for indoor use only. 

SUPPLY LINE

: The minimum recommended line size is 1/2" IPS with 30-90 psi (2-6 ATM) 

flowing pressure.  

PLUMBING CONNECTIONS:

  Inlet is 3/8” O.D. push-in type fitting.  

 

ELECTRICAL CONNECTIONS

: 115VAC, 60HZ, approx. 0.1A.  Unit is equipped with a 

standard 115VAC plug (see Installation Drawing). 

MAINTENANCE: 

Periodically change filter (based on filter monitor or decreased flow).  

Periodically check the inline valve strainer. Change filter monitor batteries.  Replace any 
blown fuse. Regularly clean drain basin. See maintenance section for details. 

 

INSTALLATION PROCEDURE 

NOTES: 

 

1.  WARNING:  Make certain power is disconnected before servicing to reduce 

risk of electrical shock. 

 

2.  This unit is intended for indoor use only. 

 

3.  For all plastic push-in type fitting connections, push tubing into fitting until it 

bottoms out to ensure a watertight connection.  To remove, depress collet and 
pull tubing out. 

 

4.  O-rings on filter cartridge must be lubricated prior to insertion into filter head 

to ensure a proper fit and seal. 

 
5.  There is an opening in the back of the unit to accommodate a waste bend.  If a 

plumbed waste is desired, a waste retrofit kit is available.   

 

Refer to Installation Drawings for details.  Use NSF-61 approved pipe joint sealant on all 
threaded water connections. 

 

STEP 1:

  Remove the rear cover/mounting bracket by unscrewing the four mounting screws 

on the top and sides (requires a T30 Torx driver).  The rear cover/mounting 
bracket should now be free of the rest of the unit. 

 

 

STEP 2: 

Open small box located inside main carton and remove drain basin assembly.  
Install drain basin assembly into front of unit as indicated on Installation Drawing; 
push in until snap latches are fully engaged.

 

 

Содержание Hydration Station 2000SM

Страница 1: ... HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general special or consequenti...

Страница 2: ...basin See maintenance section for details INSTALLATION PROCEDURE NOTES 1 WARNING Make certain power is disconnected before servicing to reduce risk of electrical shock 2 This unit is intended for indoor use only 3 For all plastic push in type fitting connections push tubing into fitting until it bottoms out to ensure a watertight connection To remove depress collet and pull tubing out 4 O rings on...

Страница 3: ...or cartridge to seat note arrows on cartridge Attach filter monitor battery connector to filter monitor battery pack STEP 6 Use supplied magnetic key to unlock magnetic latch in plastic upper body panel place key on front of body panel opposite magnetic latch see Installation Drawing and pull panel open key will stay on panel by itself if it is in the right location Slots are provided in the upper...

Страница 4: ...ever bacteria may build up in the drain therefore it is recommended to regularly clean the drain basin with a disinfectant such as Clorox Disinfecting Cleaner To access drain basin for cleaning open the upper body panel and remove the two screws holding the drain grate in place requires T 20 Torx driver STEP 3 Periodically assure that the sensor window is clean on the outside STEP 4 The filter has...

Страница 5: ...e plugged into monitor b Replace batteries c Replace filter monitor 3 Continuous water flow a Solenoid valve sticking Clear obstruction or replace valve b Check sensor window for obstruction if it is obstructed it may have automatically shut off after 30 seconds and will not reactivate until the obstruction is removed c Contact Haws Technical Support 4 Unit does not activate a Check sensor window ...

Страница 6: ...ISASSEMBLE SENSOR DAMAGE MAY RESULT STEP 2 With power on and door closed look closely at LEDs in nozzle assembly to confirm that the LEDs are flashing at reduced brightness This indicates that the unit is receiving power STEP 3 If LEDs are not flashing check the fuse and replace if necessary STEP 4 If fuse is good and LEDs are not flashing use a voltmeter to check for 120 VAC at the Open terminal ...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Отзывы: