01/10
Model 2000SM
Page 2 of 9
RECOMMENDED TOOLS
: T-20 Torx driver, level, flathead screwdriver, Phillips #3
screwdriver.
RECOMMENDED PARTS (NOT SUPPLIED)
: 8-12 #6 sheet metal screws, ½” screwdriver
stop, 3/8” tubing, 6 1/8” x 3” zinc-plated steel toggle bolts, 6 zinc-plated steel 1/8” female
washers.
LOCATION OF UNIT:
When installing this unit, local, state or federal codes should be
adhered to. If height other than shown is required, then dimensions must be adjusted
accordingly. This unit is intended for indoor use only.
SUPPLY LINE
: The minimum recommended line size is 1/2" IPS with 30-90 psi (2-6 ATM)
flowing pressure.
PLUMBING CONNECTIONS:
Inlet is 3/8” O.D. push-in type fitting.
ELECTRICAL CONNECTIONS
: 115VAC, 60HZ, approx. 0.1A. Unit is equipped with a
standard 115VAC plug (see Installation Drawing).
MAINTENANCE:
Periodically change filter (based on filter monitor or decreased flow).
Periodically check the inline valve strainer. Change filter monitor batteries. Replace any
blown fuse. Regularly clean drain basin. See maintenance section for details.
INSTALLATION PROCEDURE
NOTES:
1. WARNING: Make certain power is disconnected before servicing to reduce
risk of electrical shock.
2. This unit is intended for indoor use only.
3. For all plastic push-in type fitting connections, push tubing into fitting until it
bottoms out to ensure a watertight connection. To remove, depress collet and
pull tubing out.
4. O-rings on filter cartridge must be lubricated prior to insertion into filter head
to ensure a proper fit and seal.
5. There is an opening in the back of the unit to accommodate a waste bend. If a
plumbed waste is desired, a waste retrofit kit is available.
Refer to Installation Drawings for details. Use NSF-61 approved pipe joint sealant on all
threaded water connections.
STEP 1:
Remove the rear cover/mounting bracket by unscrewing the four mounting screws
on the top and sides (requires a T30 Torx driver). The rear cover/mounting
bracket should now be free of the rest of the unit.
STEP 2:
Open small box located inside main carton and remove drain basin assembly.
Install drain basin assembly into front of unit as indicated on Installation Drawing;
push in until snap latches are fully engaged.