RECOMMENDED TOOLS:
Hack saw; pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open end
wrench.
LOCATION OF UNIT:
The Model HWCT8 Cooler is a wheelchair accessible drinking water
facility. The height dimensions shown, meet current ADA requirements. When installing this unit,
local, state or federal codes should be adhered to. If height other than shown is required, then
dimensions must be adjusted accordingly.
SUPPLY LINE:
The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM)
pressure. Where sediment or mineral content is a problem, an inlet filter is recommended.
PLUMBING CONNECTIONS:
Inlet is 3/8“O.D. tube. Waste trap outlet is 1-1/4” O.D Tube.
ELECTRICAL CONNECTIONS:
115VAC, 60HZ, 4.7 AMPS. Chiller wired direct to incoming line, by
others.
PARTS LIST
MODEL PACKAGE
QUANTITY
ITEMS INCLUDED
MTGFR.HWCT
1
Mounting Frame
2
#10 Sheet Metal Screws
HCR8 1
Chiller
HWCT8 1
Bowl
Assembly
1
Package supply tubing and strainer
1
Panel
1
Grille
1
Package of four each-grille
attachment, attachment clips, clip
nuts, #10 sheet metal screws and 6-
32 screws and 10-24 wing nuts.
INSTALLATION PROCEDURE
GENERAL NOTES:
The Model HWCT8 Water Cooler assembly requires installation of the mounting frame as
described in Steps 1 - 2, then mounting the fountain bowl assembly as described in Steps 3 - 6,
and finally completing chiller water and electrical connections and starting chiller per Steps 7 -
10. First check that all required parts are received.
Grounding may cause electrical feedback into the electric drinking fountain causing an
electrolysis, which creates a metallic taste or an increase in the metal content of the
water. This condition can be avoided by using dielectric couplings in the assembly. The
fountain is furnished with a nonmetallic strainer at the supply, which should meet this
requirement. The waste line, which is supplied by the installer, should also have a
dielectric (plastic) coupling to completely isolate the assembly from the building
plumbing system.
For all plastic push-in type fitting connections; push tubing into fitting until it bottoms
out to ensure a watertight connection. To remove, depress collette and pull tubing out.