Страница 1: ...upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall no...
Страница 2: ... fasten with 3 8 16 UNC Hex nuts and 3 8 washers Not supplied Seal and tighten floor flange and 1 1 4 tee making certain the waste tee is facing the proper location and the foot control holes are facing side to side STEP 3 Assemble nipple 1 1 4 x 21 1 2 to the tee and tighten with a pipe wrench STEP 4 Assemble the eye face wash loop assembly to the 21 1 2 nipple from Step three Connect the pipe wr...
Страница 3: ... Possible non leveled eye face wash assembly 5 Water does not drain properly 5 Check your drain system for debris Check the main waste line of your building to see if it does handle the capacity required for the entire drainage system 6 Water leak between joints or fittings 6 Tighten loose connections If leak persists the application of hot water will sometimes reseat improperly applied joint comp...