03/18 

Model 7501BLH/7501BL240H 

Page 4 of 6 

 

 

STEP 4:

  Wrap the blanket up and over the 7501 tank and attach bottom Velcro closures. 

 

 
STEP 5:

  Fold side flaps to over sides of tank using the Velcro to attach the edges together. 

 

 

 

STEP 6: 

Pull open/down eyewash flap and yellow eyewash arm. Attach webbing loop around 
eyewash arm below eyewash heads.  

 

       

 

 

STEP 7: 

  Mount assembled eyewash and blanket in accordance with 7501TH/7501T240H 

installation instructions. 

 

IMPORTANT SAFETY NOTICE 

THE NATIONAL ELECTRICAL CODE REQUIRES GROUND-FAULT EQUIPMENT PROTECTION ON EACH 
HEATING CABLE BRANCH CIRCUIT. TO REDUCE THE RISK OF FIRE CAUSED BY DAMAGE OR IMPROPER 
INSTALLATION, CIRCUIT BREAKERS SUCH AS SQUARE D QO-EPD AND QOB-EPD OR EQUIVALENT, WITH 
A 30mA TRIP LEVEL, SHOULD BE USED. PLEASE SUBSTITUTE THESE BREAKERS WHEREVER 
REFERENCE IS MADE TO CONVENTIONAL BREAKERS IN THIS DOCUMENT. ALTERNATIVE DESIGNS 
PROVIDING COMPARABLE LEVELS OF GROUND-FAULT PROTECTION MAY ALSO BE ACCEPTABLE.  

 

Содержание 7501BLH

Страница 1: ...is agents except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and t...

Страница 2: ... a ground fault protection device 30mA GFCI for Heat Trace Electrical fault currents may be insufficient to trip a conventional circuit breaker Units are suitable for installation and use in Class 1 Division 2 Group B C D T6 Class 2 Division 2 Group F G NEMA TYPE 4 areas and MUST BE INSTALLED IN COMPLIANCE WITH LOCAL STATE AND OR FEDERAL CODES USING FLEXIBLE CONDUIT OR CABLE RATED FOR CLASS I II D...

Страница 3: ...ower cord to terminal block referencing the supplied electrical drawing The cord and fittings selected must have the appropriate hazardous rating required for the installation location The Model 7501BL240H 7501BL240H must use a ground fault protection device 30mA GFCI for Heat Trace NOTICE MODEL 7501BLH 7501BL240H REQUIRES MINIMUM NEMA TYPE 4 COMPLIANT EQUIPMENT ALL POWER CONNECTIONS MUST BE MADE ...

Страница 4: ...anket in accordance with 7501TH 7501T240H installation instructions IMPORTANT SAFETY NOTICE THE NATIONAL ELECTRICAL CODE REQUIRES GROUND FAULT EQUIPMENT PROTECTION ON EACH HEATING CABLE BRANCH CIRCUIT TO REDUCE THE RISK OF FIRE CAUSED BY DAMAGE OR IMPROPER INSTALLATION CIRCUIT BREAKERS SUCH AS SQUARE D QO EPD AND QOB EPD OR EQUIVALENT WITH A 30mA TRIP LEVEL SHOULD BE USED PLEASE SUBSTITUTE THESE B...

Страница 5: ...ermostat and heater function by applying ice thermostat for approximately 3 5 minutes The heat trace cable should become warm to the touch when operating properly Thermostat is located on junction box 2 Eyewash water is above 100 F 38 C 1 a Ambient air temperature is above 100 F 38 C Relocate eyewash out of direct sunlight or excess ambient temperature b Shut off electric power All electric connec...

Страница 6: ...6 INSTALLATION 5235 2018 CC FOR MODELS 7501BLH 7501BL240H 1 ALL MODELS MUST HAVE A GROUND FAULT PROTECTION DEVICE 30mA GFCI FOR HEAT TRACE ELECTRICAL CURRENTS MAY BE INSUFFICIENT TO TRIP A CONVENTIONAL CIRCUIT BREAKER ALL INSTALLATIONS MUST BE INSTALLED IN COMPLIANCE WITH LOCAL STATE AND OR FEDERAL CODES 2 ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO NEC CEC CODE USING FLEXIBLE CONDUIT OR CABLE...

Отзывы: