05/19
Model 1920FR
Page 2 of 7
REQUIRED TOOLS:
Tubing cutter,
3/32” and 5/32” hex key set, adjustable wrench or
socket.
LOCATION OF UNIT:
The Model 1920FR bottle filler water dispenser can be installed in
various applications. Possible installations include indoor over an existing drinking fountain,
outdoors over an existing fountain, or as a stand-alone wall-mounted bottle filler. When
installing this unit, local, state or federal codes should be adhered to.
SUPPLY LINE:
The minimum recommended line size is 3/8"O.D. copper or plastic tubing
with 30-90 psi (2-6 ATM) pressure. Where sediment or mineral content is a problem, an inlet
filter is recommended.
PLUMBING CONNECTIONS
: Inlet is 3/8“O.D. push-in type fitting.
MAINTENANCE:
Refer to 6521FR operation and maintenance sheet for more information.
INSTALLATION PROCEDURE
GENERAL NOTES:
1. For all plastic push-in type fitting connections, only connect NSF-61 copper or
plastic tubing. Stainless steel or glass tubing is not recommended. The
following assembly instructions must be followed to ensure a watertight
connection:
a. Cut tubing square and clean.
b. Mark from end of tube the length of insertion (See table below).
c. Push tube into the fitting until it bottoms out.
d. To remove, depress collet and pull tubing out.
Tube Sizes
O.D.
Tolerance
Insertion Depth
1/4”
±.005”
11/16”
3/8”
±.005”
3/4”
1/2”
±.005”
7/8”
BOTTLER FILLER BRACKET:
If installing the bottler filler in new construction, use Model 6700 or 6700.4L Mounting Plate.
Follow the installation instructions supplied with the 6700 or 6700.4L for mounting dimensions.
Reference Page 5-7 of this document for 1920FR button height when mounted over different
Haws drinking fountains.
If installing as a retrofit in old construction, it is recommended to use Model 6700 or 6700.4
Mounting Plate behind the finished wall. If that is not possible, it is recommended to install wood
stud cross-braces behind the wall and mount the 1920FR directly to the wood support. If that is
not possible, Model 6700R Retrofit Plate may be used. Follow the installation instructions
supplied with the 6700R.
If installing as a standalone bottle filler, use the mounting hole location diagram on Page 5 and
bolt the 1920FR securely to the wall.
WATER LINE:
Refer to 6521FR Manual for water line connection instructions. Refer to 6518FR Manual for
water line connection instruction in pedestal installation.
NOTE: The 1920FR is shipped with laminar
flow screens in the dispensing nozzle. In cold temperatures remove laminar screens to prevent water
from freezing and clogging the supply line.