background image

TO FLOOR

406mm

254mm

10"

305mm

12"

(OPTIONAL, HAWS 6700.4)

MOUNTING PLATE

406mm

813mm

  32"

914mm

36"

16"

16"

702mm

 27-5/8"

BACK PANEL

305mm

2-1/8"

54mm

413mm

16-1/4"

12"

305mm

12"

406mm

16"

 27"

1029mm

  40-1/2"

12.7mm

457mm

311mm

12-1/4"

18"

(BACK PANEL)

1/2"

203mm

8"

8"

203mm

6"

152mm

1-1/4" NPT

TRAP

(SUPPLIED)

WALL FACE

FLOOR LINE

(OPTIONAL)

MOUNTING PLATE

3/8" MOUNTING BOLTS

(NOT SUPPLIED)

C

9.5mm

MOUNTING

3-1/4"

83mm

TO FLOOR

27-7/16"

697mm

83mm

BACK VIEW

MOUNTING DETAIL

3-1/4"

SLOTS

2-3/4"

SUPPLY

5-1/8"

130mm

70mm

WASTE

C

3/8"

Ø

 33-1/16"

TO 

FLOOR

 840mm

WASTE

686mm

876mm

  34-1/2"

(TO SPOUT

1. HOLD ROUGH-IN DIMENSIONS ± 1/4" (6.4mm).

2. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL
    CODES SHOULD BE ADHERED TO. FOR INSTALLATION HEIGHTS
    OTHER THAN SHOWN, DIMENSIONS MARKED (*) MUST BE 
    ADJUSTED ACCORDINGLY.

3  REFER TO 5874 SERIES/VRK5874 OPERATION AND MAINTENANCE

    MANUAL FOR PUSH BUTTON AND VALVE INSTALLATION AND 
    MAINTENANCE INSTRUCTONS.

4  REFER TO RKHO SERIES OPERATION AND MAINTENANCE
    INSTRUCTONS FOR TRANSFORMER AND SENSOR SETUP.

NOTES:

 36-1/2"
927mm

 35-3/8"
899mm

 30-3/4"
781mm

 29-5/8"
752mm

L

APPROVED:

DRAWN:

PART NUMBER

SCALE:

SHEET

OF

REVISION

DRAWING TYPE:

SIZE:   A

BY:

ECN NO.

PA

GE

DATE:

DATE:

ECN:

REVISED PER

CHK'D.:

PAGE

         Haws Corporation - All Rights Reserved. HAWS   and other trademarks used in these materials are the exclusive property of Haws Corporation.

C

R

MODEL(S)

1455 KLEPPE LANE

SPARKS, NEVADA  89431

(775) 359-4712  FAX (775) 359-7424

E-MAIL:  [email protected]
WEBSITE: WWW.HAWSCO.COM

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.

FV

10/23/20

1

0510001123.D

1119HO/1119HO2

 

1:14

1

2

FV

10/29/20

 5605

SLS

6 OF 

7

INSTALLATION

 5605

6 O

F

 7

2020

FV

OUTLET)

(TO SPOUT

OUTLET)

L

TRANSFORMER STYLE
SHOWN MAY NOT
REFLECT ACTUAL
TRANSFORMER USED

120VAC-24VAC 

TRANSFORMER

AND HO CABLE

(SUPPLIED) 

FROM DIRECT

CONTACT WITH WATER

MUST BE PROTECTED

LOCATE AND INSTALL
ELECTRICAL

24VAC

TRANSFORMER
WITHIN WALL

SENSOR
EYE

WASTE

SUPPLY

WASTE

SUPPLY

4

SOLENOID

NEUT

BLK

RED

SENSOR

TO VALVE

24VAC IN

24VAC

SW 24VAC

J2 1

2

TRANSFORMER

WHT

CABLE WIRING DIAGRAM 

NOT USED

SOLENOID
VALVE

4

4

Ø3/8" SUPPLY TUBING IS
SUPPLIED. SCREWDRIVER
STOP (NOT SHOWN) IS 

NOT SUPPLIED.

REGULATOR

3

MODEL 1119HO SHOWN

MODEL 1119HO2 ON SHEET 2

(ROUGH-IN DIMENSIONS APPLY TO BOTH MODELS)

Содержание 1119HO

Страница 1: ...not be liable for the cost of repairs alterations or replacements or for any expense connected therewith made by the owner or his agents except upon written authority from HAWS Sparks Nevada HAWS wil...

Страница 2: ...ll of building provided transformer shall be mounted inside the wall and protected from water as shown on RKHO Series O M details page 8 per NEC CEC and local code Sensor s 1119HO with RKHO 120 120P 1...

Страница 3: ...r break in period readjustment Model 1119HO 1119HO2 5867 Valve Pressure Regulator Adjust bubbler stream height using the black pressure regulator mounted inside bracket that has HO sensor unit by loos...

Страница 4: ...5 REF 3 4 1 STRAINER WASTE ASSY 1 BACK PANEL 2 BUBBLER HEAD ASSY PCP 3 PUSH BUTTON ASSY 4 BUTTON PUSH FLANGED PCP W VALVE 5 PLATE BOTTOM 6 8 9 5703M PBA6 5874PBF PBM1105 0004023580 6462 ITEM DESCRIPT...

Страница 5: ...NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AN...

Страница 6: ...APPROVED DRAWN PART NUMBER SCALE SHEET OF REVISION DRAWING TYPE SIZE A BY ECN NO PAGE DATE DATE ECN REVISED PER CHK D PAGE Haws Corporation All Rights Reserved HAWS and other trademarks used in these...

Страница 7: ...NTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE FV 10 23 20 1 0510001123 D 1119HO 1119HO2 1 14 2 2 FV 10 29 20 5605 SLS 7 OF 7 INSTALLATION 5605 7 OF 7 2020 FV TRANSFORMER ST...

Отзывы: