FCC Warning 

This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to Part 15 of the FCC Rules. These limitations are designed to 
provide reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the 
following measures: 
 

• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into a different outlet from the one that the receiver is 
connected to. 

• 

Consult your local distributors or an experienced radio/TV technician for 
help. 

• 

Shielded interface cables must be used in order to comply with emission 
limits. 

 
Changes or modifications to the equipment, which are not approved by the party 
responsible for compliance, could affect the user’s authority to operate the equipment. 
 

CE Mark Warning 

This equipment complies with the requirements relating to electromagnetic 
compatibility, EN 55022 class A for ITE, the essential protection requirement of 
Council Directive 89/336/EEC on the approximation of the laws of the Member States 
relating to electromagnetic compatibility. 
 

LIMITED WARRANTY 

Hawking Technology guarantees that every HFS24T 24-Port 10/100M Rack Mount 
Switch is free from physical defects in material and workmanship under normal use 
for two (2) years from the date of purchase.  If the product proves defective during this 
two-year warranty period, call Hawking Customer Service in order to obtain a Return 
Authorization number.  The warranty is for repair or replacement only.  Hawking 
Technology does not issue any refunds.  BE SURE TO HAVE YOUR PROOF OF 
PURCHASE.  RETURN REQUESTS CANNOT BE PROCESSED WITHOUT 
PROOF OF PURCHASE.  When returning a product, mark the Return Authorization 
number clearly on the outside of the package and include your original proof of 
purchase. 
 
IN NO EVENT SHALL HAWKING TECHNOLOGY’S LIABILITY EXCEED THE 
PRICE PAID FOR THE PRODUCT FROM DIRECT, INDIRECT, SPECIAL, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE 

Содержание H-FS24T

Страница 1: ...HFS24T 24 Port 10 100M Rack Mount Switch 1...

Страница 2: ...its Changes or modifications to the equipment which are not approved by the party responsible for compliance could affect the user s authority to operate the equipment CE Mark Warning This equipment c...

Страница 3: ...e contents or use of this documentation and all accompanying software and specifically disclaims its quality performance merchantability or fitness for any particular purpose Hawking Technology reserv...

Страница 4: ...Package Contents 5 Introduction 6 Features 7 Select Features Summary 8 Hardware Description 9 Hardware Installation 11 N way Process 13 Specifications 14 4...

Страница 5: ...nstalled by manufacturer 19 Rack Mount Kit One Power Cord One User s Manual Check to make sure that the unit was not damaged during shipping and that no items are missing If you encounter a problem pl...

Страница 6: ...nd Forward architecture filters eliminate error packets and improve efficiency The HFS24T also utilizes auto MDI MDIX technology which enables you to use either standard Ethernet cables or crossover E...

Страница 7: ...forwarding and filtering at non blocking full wire speed Supports 10 100M and Link Activity LED modes with Power on auto diagnostic Supports IEEE 802 3x flow control for full duplex operation Supports...

Страница 8: ...ble for the destination address If not found the packet will be forwarded to all other ports except the port from where the packet came in If found and the destination address is located at a differen...

Страница 9: ...4 10 100M auto negotiation auto MDI MDIX RJ 45 Ethernet ports 2 Corresponding LED indicators along with one additional Power on LED indicator Rear Panel The rear panel includes a power cord input for...

Страница 10: ...ain unlit when there is a 10Mbps connection Link Activity LEDs from the two rows labeled Link Activity are lit when there is a connection to a corresponding port and blink whenever reception or transm...

Страница 11: ...Power LED does not light up check the power cord to ensure that it is properly connected to the power outlet If the Power LED still remains unlit please contact your dealer for support Ethernet Port C...

Страница 12: ...ver secure the screws into the bracket mounting holes on the unit 3 Place the unit onto the rack by securing the mounting brackets to the mounting strips on either side of the rack To do this align th...

Страница 13: ...with another network device Auto negotiation or auto sense functions are determined by these set data transfer rate priorities 1 100Base TX Full Duplex 200 Mbps 2 100Base TX Half Duplex 100Mbps 3 10Ba...

Страница 14: ...ors Power Lit green when power is on 10 100M Lit green when there is a 100Mbps connection unlit when there is a 10Mbps connection Link Activity Lit for successful connection flashing for activity Syst...

Отзывы: