AMPLIFIER
Select a suitable mounting position that
is not in direct sunlight. If necessary, uti-
lize a sunshade. Observe the minimum
and maximum temperature limits (c-f).
Do not mount near sources of high
E.M.F. such as high current cables,
motor starters, or S.C.R. variable speed
drives.
Avoid mounting in high vibration areas
such as handrails and rotating plant. Use
rubber absorption mounts if mounting in
light vibration areas.
INSTALLATION GUIDE
Blanking distance (450mm)
Example 20kHz flow transducer above trapezoidal weir
(not to scale)
Transducer face
+100% (total 900mm)
BLANKING DISTANCE
The blanking distance is the distance
prior to the minimum measureable
distance from the face of the transducer.
When the transducer pulses it vibrates
the transducer face which can create &
detect unwanted echoes. As a result the
internal software creates a ‘blank’ zone
approximately 250-450mm (depending
on the transducers power) from the face
of the transducer.
As a result the transducer face must al-
ways be mounted a minimum the blank-
ing distance away from the liquid. Ideally
the blanking di 50-100% of this
distance (eg, for a 20kHz with a 450mm
blanking distance we would recommend
700-1000mm between the transducer
face and the liquid).
Содержание Sultan Flow Series
Страница 1: ...INSTRUCTION MANUAL SULTAN FLOW Acoustic Wave Technology A higher level of performance DRAFT ...
Страница 11: ...11 Sultan Flow Series MANUAL Draft 1 2 Mar 2009 ...
Страница 13: ...13 Sultan Flow Series MANUAL Draft 1 2 Mar 2009 BS3680 FLUMES ...
Страница 16: ...Sultan Flow Series MANUAL Draft 1 2 Mar 2009 16 BS3680 RECTANGULAR WEIR ...
Страница 18: ...Sultan Flow Series MANUAL Draft 1 2 Mar 2009 18 BS3680 Thin Plate Weirs ...